Claim Missing Document
Check
Articles

Found 2 Documents
Search

Identification of Underground River Flow Using VLF (Very Low Frequency) and Geoelectricity at Karstic Area Marbun, Mahmuddin; Sismanto, Sismanto; DE, Zuhrahmi; Tarique, Imran; Korai, Punhoon Khan
International Journal of Hydrological and Environmental for Sustainability Vol 2, No 3 (2023): International Journal of Hydrological and Environmental for Sustainability
Publisher : CV FOUNDAE

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58524/ijhes.v2i3.332

Abstract

Mapping underground river karst areas in the karst mountains Cianjur, West Java, has been done using electromagnetic methods and Geoelectricity Dipole-dipole. Karst constituent formation region of West Java area is limestone, clay stone, limestone fractured, hard and dense limestone, and limestone containing no water (rigid). The aim of this research is to search for the existence of underground rivers using electromagnetic and geoelectric wave surveys. VLF method consists of 13 line with a length of 750 m and a 10 m spacing. Based on the results of data processing VLF method is known that the equivalent current density (ECD) demonstrated high conductive rocks. While Geoelectricity method consists of 10 line, the arrangement is a parallel between the distance of the line with a space of 20 m andlength between 300 m.VLF data interpretation results indicate anomalous equivalent current density (ECD) with high scores range from 180-300% indicated fractured limestones are occupied by water, while the resistivity anomaly from 0.45 to 7.40 Ω.m indicated as weathered limestone layers accumulated dengn clay stone, resistivity values 186-701 Ω.m, fractured limestones indicated that fills with water. With sizes ranging 5-15 m cavity, each line with nearly the same distance at a depth of approximately 15-105 m, there is a large cavity-cavity interconnected.
VES Geoelectrical Method for Identification of Aquifer Depth in Coastal Area of North Lombok Regency, Indonesia: Implications for the Sustainable Utilization of Water Resources Anwar, Haerul; Wijaya, Arif; Faisal, Faisal; Korai, Shakal Khan; Tarique, Imran; Korai, Punhoon Khan
International Journal of Hydrological and Environmental for Sustainability Vol 2, No 1 (2023): International Journal of Hydrological and Environmental for Sustainability
Publisher : CV FOUNDAE

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58524/ijhes.v2i1.176

Abstract

Measurement of the resistivity value distribution of subsurface rocks has been carried out in Mumbul Sari Village, Bayan District, North Lombok, which is one of the drought-prone areas in NTB Province, Indonesia. This research was conducted to identify the presence of groundwater aquifer layers in the study area based on the distribution of resistivity values. Data collection was carried out at two measurement points, namely the MBLS-1 Point with a track length of 700 m and the MBLS-2 Point with a length of 750 m. Data processing was carried out using IP2WIN Software to obtain a one-dimensional subsurface cross-sectional model, then interpreted using a resistivity log to make it easier to draw information on the subsurface point of measurement. Based on the distribution of resistivity values, it is known that the geological layers in the study area consist of pumice tuff, silty silt, sandy silt, and lava. The inversion results from the IP2WIN software show that the depth of the aquifer zone at Point MBLS-1 is 15.6 – 70.2 m with a resistivity value of 90.3 Ωm and a thickness of 54.5 m, while at Point MBLS-2 it is located at a depth of 21.9 – 86.1 m with a resistivity value of 112 Ωm and a thickness 64.3m. The aquifer zone at both measurement points is interpreted as a sandy silt layer. Groundwater drilling is recommended at the MBLS-1 point to a depth of 70 m and at the MBLS-2 point to a depth of 86 m. The geological structure that forms the boundary of the aquifer zone is a layer of compact and hard lava, so for groundwater utilization in the study area, it is recommended to use drilled wells to a depth of 70 – 86 m which is the lower limit of the aquifer layer.