Muhammad Dicky Saputra
Unknown Affiliation

Published : 3 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 3 Documents
Search

Efek Menguntungkan Dari Medan Elektromagnetik Muhammad Dicky Saputra; Andi Purwanto; Danna Rayana; Aulivia Widya Putri; Diyajeng Luluk Karlina
Mars: Jurnal Teknik Mesin, Industri, Elektro Dan Ilmu Komputer Vol. 2 No. 6 (2024): Desember: Mars: Jurnal Teknik Mesin, Industri, Elektro Dan Ilmu Komputer
Publisher : Asosiasi Riset Teknik Elektro dan Informatika Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61132/mars.v2i6.530

Abstract

This study examines the intense competition in the contemporary franchise beverage industry in Gorontalo City, where consumers have many choices that affect loyalty to certain brands. This study aims to analyze the effect of brand equity and marketing mix on customer loyalty. This descriptive quantitative research uses accidental sampling with 100 samples. Data analysis includes statistical tests as well as Structural Equation Modeling (SEM) models. This study shows that brand equity and marketing mix have a positive and significant effect on purchasing decisions, both partially and simultaneously, with the t-count and f-count values exceeding the table limit at the 95% confidence level. SEM-PLS analysis confirmed the significant relationship with p-values of 0.05 and t-statistics of 1.96, supporting the tested model. The research conclusion shows that brand equity and marketing mix have a significant influence on purchasing decisions. As advice, business owners of contemporary beverage franchises in Gorontalo City are advised to strengthen brand equity, as well as optimize creative and effective marketing strategies to increase competitiveness.
Komunikasi Data Menggunkan Topologi Tree Nazwa Amelia Purnama; Muhammad Dicky Saputra; Gilang Nur Rosyid; Paul Manurung; Didik Aribowo
Uranus: Jurnal Ilmiah Teknik Elektro, Sains dan Informatika Vol. 2 No. 2 (2024): Juni: Uranus: Jurnal Ilmiah Teknik Elektro, Sains dan Informatika
Publisher : Asosiasi Riset Teknik Elektro dan Informatika Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61132/uranus.v2i2.95

Abstract

In the era of digital communication, access speed and data security are crucial. The study evaluated network topology, focusing on tree topology using simulations with Cisco Packet Tracer. Tests highlighted stability, latency, throughput, and bottleneck potential. Data transmission time information is key in assessing network performance. Test results are important for optimizing performance and identifying areas of improvement in the network. In conclusion, monitoring network performance is an important step for operational efficiency and security.
Studi Kasus Integrasi Current Transformer (CT) dan EOCR untuk Pengamanan Arus pada Panel Cooling Tower Pump di PT DongJin Indonesia Muhammad Dicky Saputra; Mohammad Fatkurrokhman
Jurnal Kendali Teknik dan Sains Vol. 4 No. 2 (2026): April: Jurnal Kendali Teknik dan Sains
Publisher : International Forum of Researchers and Lecturers

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59581/jkts-widyakarya.v4i2.6065

Abstract

Three-phase induction motors are essential components in industrial cooling systems that require reliable overcurrent protection to maintain operational continuity and prevent equipment damage. In the Cooling Tower Pump panel at PT DongJin Indonesia, a limitation was identified where the terminal of the Electronic Overcurrent Relay (EOCR) could not accommodate the 50 mm² power cable, preventing direct current measurement. This study aims to analyze the effectiveness of integrating a 200:5 A Current Transformer (CT) with the EOCR as an adaptive protection solution that is both safe and efficient. The research employs a case study approach through field observation, motor current measurement using a Fluke 303 Clamp Meter, and descriptive analysis of the recorded data. The results indicate that the three motors operate under stable load conditions, with current values ranging from 236.7 A to 275.7 A, while the secondary current detected by the EOCR ranges from 3.7 A to 3.9 A, consistent with the CT transformation ratio. During the starting phase, the current surged to 600.4 A without causing false tripping, demonstrating that the EOCR effectively distinguishes temporary inrush current from actual fault conditions. Therefore, the integration of CT–EOCR is proven to enhance measurement safety, maintain motor operational stability, and support efficient system maintenance in industrial environments.