Claim Missing Document
Check
Articles

Found 2 Documents
Search

EVALUASI PENEMPATAN APAR PADA GUDANG MATERIAL KETINTANG DI PT.X SURABAYA Prastya, Deny Nurcahyo Hari; Martiana, Tri; Parlan, Parlan
Journal of Industrial Engineering and Operation Management (JIEOM) Vol 7, No 2 (2024)
Publisher : Universitas Islam Kalimantan Muhammad Arsyad Al Banjari Banjarmasin

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31602/jieom.v7i2.16375

Abstract

Penelitian ini mengevaluasi penempatan Alat Pemadam Api Ringan (APAR) di Gudang Material Ketintang PT.X Surabaya, bertujuan mengoptimalkan sistem proteksi kebakaran. Metode penelitian menggunakan pendekatan deskriptif observasional, studi dilakukan Agustus-September 2024, melibatkan observasi langsung, wawancara, dan analisis dokumen. Penelitian mengacu pada Permenakertrans No.04/MEN/1980, Kepmenaker No.186/MEN/1999, dan NFPA-10 edisi 2022. Temuan utama mengungkap ketidaksesuaian signifikan: jumlah APAR tidak memadai, peletakan tidak sesuai standar, dan penandaan tidak lengkap. Analisis risiko menunjukkan potensi bahaya serius akibat kekurangan ini, termasuk keterlambatan respons dan kesulitan akses saat darurat. Perhitungan berdasarkan luas area dan standar yang berlaku merekomendasikan penambahan 8 unit APAR, mencapai total 17 unit. Rekomendasi mencakup penataan ulang distribusi APAR, penyesuaian ketinggian pemasangan, dan penambahan penanda yang jelas. Implementasi rekomendasi ini penting untuk meningkatkan efektivitas sistem proteksi kebakaran. Kesimpulannya, perbaikan manajemen APAR di gudang sangat diperlukan untuk menjamin keselamatan kerja dan perlindungan aset.Kata Kunci:  APAR, Gudang Material, Kebakaran, Penataan
Evaluasi dan Re-Mapping APAR di Lingkungan Gedung Perkantoran PLN UID Jawa Timur Prastya, Deny Nurcahyo Hari; Martiana, Tri; Parlan
Journal of Applied Civil Engineering and Infrastructure Technology Vol 6 No 2 (2025): Desember 2025
Publisher : Indonesian Society of Applied Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.52158/jaceit.v6i2.976

Abstract

This research aims to evaluate and re-map the Portable Fire Extinguishers (PFE) in the office buildings of PLN UID East Java. The method employed is a descriptive observational approach, gathering primary data through direct observation and structured interviews, supplemented by secondary data from document reviews. The findings reveal a gap between fire safety standards and actual conditions, such as improper PFE placement, unclear expiration dates, and an uneven distribution of PFE across buildings. Risk analysis identifies hazards from these issues, including delayed fire response and potential failure of PFE during emergencies. Calculating PFE needs based on Permenakertrans Regulation No. 04/MEN/1980 and NFPA-10 edition 2022 generates recommendations for redistributing PFE. Based on these calculations, three buildings (C, F, I) are found to have an excess of 13 PFE, while four buildings (A, B, D, E) are short by 9 PFE. The recommendation suggests transferring 11 PFE from Building F: 4 PFE to Building A, 3 PFE to Building B, and 2 PFE each to Buildings D and E. This redistribution ensures the correct number of PFE in each building, enhancing fire safety management in PLN UID Jawa Timur office buildings. This action aims to align the PFE distribution with safety requirements.