Indonesian Journal of Chemistry
Vol 16, No 1 (2016)

A Rapid and Sensitive Diagnosis of Typhoid Fever Based On Nested PCR-Voltammetric DNA Biosensor Using Flagellin Gene Fragment

Yeni Wahyuni Hartati (Department of Chemistry, Faculty of Mathematics and Natural Sciences, Padjadjaran University, Jl. Raya Bandung-Sumedang Km 21, Jatinangor, Sumedang 45363, East Java)
Santhy Wyantuti (Department of Chemistry, Faculty of Mathematics and Natural Sciences, Padjadjaran University, Jl. Raya Bandung-Sumedang Km 21, Jatinangor, Sumedang 45363, East Java)
M. Lutfi Firdaus (Graduate School of Science Education, Bengkulu University, Jl. Raya Kandang Limun, Bengkulu 38371)
Nurul Auliany (Department of Chemistry, Faculty of Mathematics and Natural Sciences, Padjadjaran University, Jl. Raya Bandung-Sumedang Km 21, Jatinangor, Sumedang 45363, East Java)
Rini Surbakti (Department of Chemistry, Faculty of Mathematics and Natural Sciences, Padjadjaran University, Jl. Raya Bandung-Sumedang Km 21, Jatinangor, Sumedang 45363, East Java)
Shabarni Gaffar (Department of Chemistry, Faculty of Mathematics and Natural Sciences, Padjadjaran University, Jl. Raya Bandung-Sumedang Km 21, Jatinangor, Sumedang 45363, East Java)



Article Info

Publish Date
15 Mar 2018

Abstract

Typhoid fever caused by Salmonella typhi is an important issue for public health in the world. Laboratory methods for rapid and sensitive diagnosis are very important for disease management. The purpose of this study was to determine the performance of nested PCR–voltammetric DNA biosensor using flagellin gene (fla) of S. typhi as a marker. The differential pulse voltammetry using pencil graphite electrode was applied to measure the guanine oxidation signal of probes vs synthetic target stDNA and probes vs fla PCR product hybridizations. The probe DNA selectivity was examined by hybridized probes vs non-complementary sequence. The result showed that the first round nested PCR product can not be visualized by agarose electrophoresis, whereas using the voltammetric biosensor methods can be detected both for the first or second round nested PCR product. The average peak current of hybridized probe vs first and second round of PCR product was 2.32 and 1.47 μA respectively, at 0.9 V. Detection of the DNA sequences of the infectious diseases from PCR amplified real sample was also carried out using this voltammetric DNA biosensor methods.

Copyrights © 2016






Journal Info

Abbrev

ijc

Publisher

Subject

Chemical Engineering, Chemistry & Bioengineering Chemistry

Description

Indonesian Journal of Chemistry is an International, peer-reviewed, open access journal that publishes original research articles, review articles, as well as short communication in all areas of chemistry including applied chemistry. The journal is accredited by The Ministry of Research, Technology ...