Articles
158 Documents
Penggunaan Fuzzy Logic Control Untuk Kestabilan Solar Sel Dengan Menggunakan Matlab
Firman Yudianto;
ima kurniastuti;
Nahdia rupawanti BR
Jurnal JE-UNISLA : Electronic Control, Telecomunication, Computer Information and Power System Vol 6, No 2 (2021)
Publisher : Universitas Islam Lamongan
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.30736/je-unisla.v6i2.696
Solar cell are currently needed and have been widely used in Indonesia asan alternative energy to help supply energy. This energy reliability will be moreeffective if the maximum power usage is monitored by measurement andsimulation. FLC is carried out to test the correctness of the value of thesimulink module block with solar cell panels, namely short circuit currenttesting and open circuit voltage testing. The simulation was carried out withirradiation of 1000 W/m2 and a temperature of 25 degrees Celsius withtechnical data of solar cell panels.Result of test the solar panel system that is connected to the load usingthe MPPT system, it is carried out with the same irradiation and temperaturevalues as in the simulation without MPPT. In the system also installed a load inthe form of a resistor. Based on the test results without MPPT, to reach themaximum power point, the FLC output is expected to be close to the value ofthe duty cycle of 1% to 35%.
Analisa Penggunaan Mesin X-Ray Sebagai Security System Di Bandara Internasional Husein Sastranegara
Galih Abu Ayub
Jurnal JE-UNISLA : Electronic Control, Telecomunication, Computer Information and Power System Vol 6, No 2 (2021)
Publisher : Universitas Islam Lamongan
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.30736/je-unisla.v6i2.687
Security system is a protection has a structured cycle, meaning that it has been systemized according to its application in the environment according to its field. Security system is formed is because of threats, crimes and others. A security system is needed at certain events and in special places such as malls and airports to maintain the continuity of the event and security can be well maintained. Everyone who comes to the location must have their luggage checked to minimize the presence of sharp objects that endanger or threaten security at the location. Inspection of passenger objects at the airport is one way to protect the safety and security of airplane passengers. The procedure for checking objects carried by passengers is still carried out manually by airport security officers. The goal is to check whether you find sharp objects or illegal drugs in the passenger's bag. The results of this study are the authors know the working principle and operation of x-ray machines, as well as the number and types of x-ray machines used by Husein Sastranegara International Airport. Security system is a protection has a structured cycle, meaning that it has been systemized according to its application in the environment according to its field.Security system is formed is because of threats, crimes and others. A security system is needed at certain events and in special places such as malls and airports to maintain the continuity of the event and security can be well maintained. Everyone who comes to the location must have their luggage checked to minimize the presence of sharp objects that endanger or threaten security at the location. Inspection of passenger objects at the airport is one way to protect the safety and security of airplane passengers. The procedure for checking objects carried by passengers is still carried out manually by airport security officers. The goal is to check whether you find sharp objects or illegal drugs in the passenger's bag. The results of this study are the authors know the working principle and operation of x-ray machines, as well as the number and types of x-ray machines used by Husein Sastranegara International Airport.
Implementasi Sensor Proximity Kapasitif Pada Alat Pemberian Pakan Ayam Otomatis
Robi Bagja Nugraha;
Yuliarman Saragih;
Lela Nurpulaela
Jurnal JE-UNISLA : Electronic Control, Telecomunication, Computer Information and Power System Vol 6, No 2 (2021)
Publisher : Universitas Islam Lamongan
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.30736/je-unisla.v6i2.692
Farmers still use the conventional system to feed the chickens that are kept. They use their hands to spread the feed on the container and walk along the cage. With such a large cage, of course, it is not easy to carry out periodic supervision quickly on large-scale chicken coops. Based on these problems, therefore we need a tool that is integrated with the Internet of Things used to control and monitor the cage to automatically feed. In order to save time and human effort. Capacitive is a sensor that utilizes the concept of a capacitor, namely storing and releasing charge. This sensor works based on changes in the charge of stored electrical energy due to changes in plate distance, changes in cross-sectional area, and changes in the volumeof the sensor dielectic.
Partial Discharge yang Merusak Isolasi SF6 pada Gas Insulated Switchgear (GIS) Tiga Fasa Pengaruh Keberadaan Partikel Asing
Abednego Setiabudi Sianturi;
Josie Sidharta
Jurnal JE-UNISLA : Electronic Control, Telecomunication, Computer Information and Power System Vol 6, No 2 (2021)
Publisher : Universitas Islam Lamongan
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.30736/je-unisla.v6i2.697
This paper analyzes the effect of the presence of foreign particles on an equilateral arrangement of 3 phase gas insulated switchgear (GIS) insulation equipment. Gas Insulated Switchgear (GIS) that uses SF6 insulation, partial discharge will occur as the insulation ages and there are several other factors that affect the insulation. Partial Discharge needs to be detected to avoid failures that cause damage to equipment in theGIS. In this calculation, the electric field characteristics will be analyzed in 3-phase equilateral GIS by varying the location of the particles in the GIS tank. Particles are modeled to have a length of 5 mm and a thickness of 0.5 mm located in a 3 phase GIS equilateral arrangement with a tank diameter of 150 mm and a conductor diameter of 25 mm. The electric field calculations are reviewed at several points in the 3-phase equilateral GIS tank. The simulation and calculation of the electric field were calculated with FEM method software. The results of the calculations show that thereare differences in the characteristics of the electric field between normal GIS and GIS where foreign particles are present. The difference in these characteristics can be seen in the magnitude of the electric field, and the ratio of eccentricity from some point of view.
Pengujian Tahanan Kontak Pemutus Tenaga 70 KV Di Gardu Induk Rengas Dengklok Karawang
Muhammad Mursal Fikri;
Insani Abdi Bangsa;
Ulul Ilmi
Jurnal JE-UNISLA : Electronic Control, Telecomunication, Computer Information and Power System Vol 6, No 2 (2021)
Publisher : Universitas Islam Lamongan
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.30736/je-unisla.v6i2.688
The increasing demand for electric power every year demands to provide reliable electric power. One of the important parts to support the reliability of the electric power system is the substation. Substation is a subsystem of the electric powerdistribution system. One of the materials from the substation is a Circuit Breaker (CB) which is a switch that is used to open or close an electrical circuit under load conditions, and is able to connect or disconnect electrical circuits during normal conditions or when a fault current occurs. The CB needs to be maintained to maintain the reliability of CB. This research aims to determine the value of contact resistance in CB. In this research, data were collected from the last 2 periods of maintenancecarried out at the Rengas Dengklok Substation, PT. PLN (Persero) Karawang.Overall with the maintenance and testing of CB contact resistance, the reliability ofthe CB is maintained and can work normally
Implementasi Sistem Kontrol Motor Ac Berbasis Arduino Uno Pada Alat Ecosystem (Evaporatif Cooler System)
Rizki Sya'bani;
Reni Rahmadewi;
Dian Budi Santoso
Jurnal JE-UNISLA : Electronic Control, Telecomunication, Computer Information and Power System Vol 6, No 2 (2021)
Publisher : Universitas Islam Lamongan
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.30736/je-unisla.v6i2.693
Globalization era has a negative impact on the environment, one of which is affected by temperature. The condition of a hot room can cause an uncomfortable feeling to move in the room. The best room temperature for human comfort is 29°.ECOSYSTEM is an air conditioner that uses an indirect evaporative cooling system with control using Arduino uno and an application. This tool is made to cool the air in the room with the control of a cellphone. This research can be proven to be successful because the program code with the tool runs well. From the experiment it is also proven that when the speed increases, the current, watts, and RPM increase linearly.With this ECOSYSTEM tool, it is able to cool the room compared to a fan. Although the power generated is greater. Because the components used are different from conventional fans.
Desain Hibrid Menggunakan PID-ANFIS Controller Pada Motor DC Berbasis PSO (Particle Swarm Optimization)
Machrus Ali;
Ahmad Ali Syaifudin;
Hidayatul Nurohmah
Jurnal JE-UNISLA : Electronic Control, Telecomunication, Computer Information and Power System Vol 6, No 2 (2021)
Publisher : Universitas Islam Lamongan
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.30736/je-unisla.v6i2.707
DC motors can be used as generators or motors. For this reason, it is necessary to design the best DC motor speed regulation in order to obtain the best optimization. DC motor setting modeling must be adjusted to the DC motor characteristics and setting model. The results of the performance of the DC control model have a different steady-state error, settling time, and overshoot. From the results of running the program, it is found that the PID-PSO-ANFIS hybrid control model produces the best output performance. The results of PID-PSO-ANFIS optimization show that there is no overshot and undershot, settling time is 0.04 seconds, the motor speed reaches a constant and stable state. This design will be developed using artificial intelligence methods and other controllers in order to obtain the best optimization.
Pengujian Tahanan Isolasi Trafo Tegangan Di Gardu Induk Telukjambe Karawang
Samsul Bahri Siregar;
Reni Rahmadewi
Jurnal JE-UNISLA : Electronic Control, Telecomunication, Computer Information and Power System Vol 6, No 2 (2021)
Publisher : Universitas Islam Lamongan
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.30736/je-unisla.v6i2.689
Electricity is a collection of components or electrical devices such as generators, transformers, transmission lines, distribution lines, and loads, which are connected and form a system. Maintenance is one of the most important things that must be considered in the operation of the electrical system. Voltage transformer is a device that transforms a higher system voltage to a lower system voltage for indicator equipment, measuring instruments, and relays. In this research, quantitatively, this is done by testing from the box panel on the voltage transformer and each coil has ameasuring limit, recording the test results is carried out at 60 seconds and there are 2 places, namely busbar 1 and busbar 2 and 6 measurements of insulation resistance on the transformer. voltage. This test is not on Phase R and Phase T because the equipment is being transferred to another substation. The results of the voltage insulation resistance test under normal and good conditions are above the minimum limit of insulation resistance and the voltage transformer is fully operational.
Penentuan Kapasitas PMT SF6 Pada Bus 70 KV Menggunakan Simulasi Program ETAP
Jeri Widianto;
Rahmat Hidayat;
Arief Budi Laksono
Jurnal JE-UNISLA : Electronic Control, Telecomunication, Computer Information and Power System Vol 6, No 2 (2021)
Publisher : Universitas Islam Lamongan
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.30736/je-unisla.v6i2.694
The electric power system consists of several components, namely generation, distribution, transmission and load. Along with the rapid development of technology in the field of electricity today, a protection system is installed at substations, one of which is a powerbreaker (PMT) at each substation. In the event of a disturbance, the protection relay will detect and instruct the breaker to open or disconnect the circuit from the disturbance, then a circuit breaker will receive a signal from the relay and in the end will decide the circuit according toits current rating. Based on the type of PMT isolation media, PMT is divided into 4 types, one of which is the SF6 gas isolation media type. This type of PMT can be used to cut currents up to 40 KA and in circuits with a voltage of 765 KV. It must be noted that if the current is very large at the time of short circuit, then the thing that must be considered is the capacity of thebreaker itself. To determine the breaker capacity, it is sought from the largest short-circuit current, namely a three-phase short circuit. In finding a three-phase short circuit current can be simulated using the ETAP (Electric Transient Analysis Program) program. ETAP can simulatepower flow and short circuit current. The results of the calculation of the PMT capacity on the 70 KV bus are 0.324 KA and from the results of the calculation and analysis of the PMT it is included in the rating of 12.5 KA where the PMT with the rating value can decide the fault current from 0.9 KA -7.74 KA
Analisa Performansi Beberapa Metode Kontroler PID Pada Magnetic Ball
Tamaji Tamaji;
Yoga Alif Kurnia Utama;
Adrianus Raffel
Jurnal JE-UNISLA : Electronic Control, Telecomunication, Computer Information and Power System Vol 6, No 2 (2021)
Publisher : Universitas Islam Lamongan
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.30736/je-unisla.v6i2.715
PID controller is a controller that is still widely used in the industrial world. ThePID controller is proven to provide good control performance even though ithas a simple and easy-to-understand algorithm. The important thing in thedesign of this PID controller is to determine the controller parameters or tuning. Project tries to implement advanced PID tuning which involves several tuning methods to get the best performance on a system or plant that is unstable or critically stable, such as controlling the height of a magnetic ball. Some of the methods that will be discussed here are Ziegler-Nichols, Non-control, On Off, Trial Error, and Chien-Hrones-Reswick (C-H-R). From results show that of the five PID Control methods to control the position of the magnetic ball, the best sequential control method is PID Control Trial Error, PID Control On Off, PID Ziegler-Nichols, Chien-Hrones-Reswick Method, and PID Non-Control