cover
Contact Name
Triwiyanto
Contact Email
triwiyanto123@gmail.com
Phone
+628155126883
Journal Mail Official
editorial.ijeeemi@gmail.com
Editorial Address
Department of Electromedical Engineering, Poltekkes Kemenkes Surabaya Jl. Pucang Jajar Timur No. 10, Surabaya
Location
Kota surabaya,
Jawa timur
INDONESIA
Indonesian Journal of electronics, electromedical engineering, and medical informatics
ISSN : -     EISSN : 26568624     DOI : https://doi.org/10.35882/ijeeemi
The Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics (IJEEEMI) is a peer-reviewed open-access journal. The journal invites scientists and engineers throughout the world to exchange and disseminate theoretical and practice-oriented topics which covers three (3) majors areas of research that includes 1) Electronics, 2) Biomedical Engineering, and 3) Medical Informatics (emphasize on intelegent system design). Submitted papers must be written in English for an initial review stage by editors and further review process by a minimum of two reviewers.
Articles 113 Documents
Design of Charger Controller on Wind Energy Power Plant With Arduino Uno Based on Pi Controller Anggara Trisna Nugraha; Dwi Sasmita Aji Pambudi; Agung Prasetyo Utomo; Dadang Priyambodo
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 4 (2021): November
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Technological developments are increasing every day. Where most human activities do not escape the use of electrical energy. The increase in world fuel oil and its scarcity has led to many new innovations, one of which is the use of renewable energy. The most widely used renewable energy is solar, wind and hydro energy. To support the effectiveness of the generator, a charger controller is needed to maintain battery performance. In this accumulator the maximum voltage required to charge is 14.4 Volts. The problem that arises is how the voltage generated from the generator does not match the voltage required in the battery charging process. From this problem, a charger controller with a buck converter circuit with the PI method was made to stabilize the output voltage for charging. The aim o this study is to make a battery charger that can stabilize the level voltage of the battery charger. From the research, it was found that the efficiency value of the charger controller is 83-95% and the average error percentage is 1.373%. For this reason, it can be concluded that the charge controller has good performance in terms of efficiency and percentage of output voltage error. The charger controller is expected to maintain battery performance and lifetime of the battery.
Design and Development of Electricity Use Management System of Surabaya State Shipping Polytechnic Based on Decision Tree Algorithm Adam Meredita Realdo; Anggara Trisna Nugraha; Shubhrojit Misra
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 4 (2021): November
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v3i4.7

Abstract

Electrical energy has become a primary need in society, including in education. This is related to the number of electrical equipment used to support teaching and learning activities. However, this is not directly proportional to the students' awareness of the importance of saving energy. From this, the authors create a management system for electric power, which aims to save electricity consumption by limiting the use of electrical loads. In this system, the method used is a decision tree; the goal is to limit and set priorities for electrical loads. When three classes are ON simultaneously, there will be a reduction in the electrical load. There is a website for monitoring and changing the automatic or manual mode in this system. The manual mode is used to control the electrical load according to the status entered on the website. While the automatic mode regulates the use of electrical loads by controlling the ON or OFF conditions using a schedule that has been made, the website also monitors current, voltage, power, energy, and usage costs. The system has been tested with automatic and manual modes for monitoring data on the website. It has data updates every 10 minutes. The system has also been tested by scheduling using a decision tree and compared with scheduling without using a decision tree. From the test results for a day, it can be concluded that the system created is able to save electricity consumption. This is reinforced by a decrease in energy use of 1,17 kWh and a cost of Rp. 1.116.
Evaluation of an Android-Based Application for Monitoring the Spread of Covid-19 in Real-Time Yasser Djawad; Ridwansyah Ridwansyah; Suhartono Suhartono; Hendra Jaya
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 1 (2022): February
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i1.2

Abstract

The increase in the number of patients infected with the Covid-19 virus from day to day shows a fluctuating number. Meanwhile, the spread of the COVID-19 virus is spreading rapidly in various ways and is difficult to predict. Therefore, mapping the spread of the COVID-19 virus is needed. Currently, the existing deployment maps are offline maps that are updated one or more times a day. It does not show real-time deployment and so rapid prevention is not possible. This study aims to develop a mapping system for the spread of the COVID-19 virus in real-time. For this reason, in this study, an Android-based COVID-19 spread monitoring application was developed in real-time using the Prototype Development Model method. The application is developed with an easy user interface to receive it well. The results of the created application show that users who use this application can connect in real-time with the developed map. Furthermore, the location of users who are exposed to or suspected of being exposed to the COVID-19 virus can be displayed in real-time on the developed map. With the map of the COVID-19 spread, it is hoped that early prevention of the spread of the virus and the introduction of patterns of virus spread can be carried out.
An Automatic Load Detector Design to Determine the Strength of Pedestrian Bridges Using Load Cell Sensor Based on Arduino Kurnia Paranita Kartika Riyanti; Ismail Kakaravada; Abdussalam Ali Ahmed
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 1 (2022): February
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i1.3

Abstract

The basic requirement that must be met in the construction of a bridge is the resilience. This resilience depends upon the supporting of bridge when the load that passes over the bridge. Loading condition on bridge is generally in the form of dynamic which ​​can vary according to crossing conditions on it. This reason validates in difficulties in estimation the lifetime of the bridge. In order to maintain the good condition of the bridge the estimation of overloading condition and its effects of over loading on bridge need to evaluate to keep the bridge durable for that a bridge load measuring detector is needed. The aim of this research is to design an automatic load detector to test the strength of the bridge at dynamic loading conditions. The load detector designed through an Arduino-based load cell sensor. The detector equipped with I2C LCD display mechanism which can display the load on bridge and buzzer switch with warning alarm which can alert when bridge is over loaded. The total sensor mechanism was tested on a miniature wooden bridge with selected loads. During testing, the detector load cell sensors placed at the bottom of the bridge surface with a running load, the readings are considered recorded for several load cells at dynamic loading conditions. In the research work was carried out on the bridge using various load ranges from 100 grams to 25 kilograms on load cells at various positions. From the experimentation it has been noticed that, the load cell has displayed the smaller value as compared with the actual value due to the load distribution over the bridge structure. From the experimental data it is noticed that the average error rate 4.67%, hence the developed sensor system more suitable for practical application to evaluate the damage of the bridge. It also concluded that, the detector is more effective in evaluation of dynamic loading condition to prevent damage of bridge.
Application of IoT Using nodeMCU ESP8266 on the Syringe Pump Device to Increase Patient Safety Annisa Gallela Anjani; Presillia Grisviani Grisviani; Royan Royan; Kusnanto Mukti Wibowo; Gema Romadhona; Rum Sapundani; Arif Mulyanto; Iwan Setiawan; Jumrianto Jumrianto; N. Prasath
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 1 (2022): February
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i1.4

Abstract

Nowadays, health care has turned out to be more technology-oriented. Today's technology is demanded to be practical and easy to use. The number of mobile devices based on the Android operating system has increased significantly based on data. The open-source nature of android helps in programming applications easily according to user requirements. The syringe pump is a medical device that functions to enter the medicinal fluid into the patient's body at a specific dose and time automatically in mL/hour. The syringe pump is generally equipped with an alarm. Alarms have a vital function to provide information to nurses or doctors on duty. Medical officers cannot hear alarms outside the patient monitoring room. This paper aims to design a syringe pump that is equipped with a NodeMCU8266 WiFi module to provide notifications via a smartphone so that nurses or doctors can know the alarm even though they are outside the patient monitoring room. So, this is expected can improve patient safety. In addition, this paper also aims to verify the size of the syringe against the drug flow rate. Based on the test results, the syringe pump can control the drug flow rate with a sensor accuracy of 0.0217 and an error rate of 0.6% at a target volume of 5mL. The syringe pump can also send alarm notifications to smartphones in real-time.
Design and Implementation of Portable and Prospective Embedded System and IoT Laboratory Kit Modules Era Madona; Yulastri Yulastri; Anggara Nasution; M Irmansyah
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 1 (2022): February
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i1.5

Abstract

The purpose of this research is to design and implement a new design of a low-cost, portable and prospective laboratory kit module. Laboratory kits are made easy to assemble, with relatively small dimensions. and suitable for use in laboratories with limited experimental space and funds. The research stages are carried out starting with needs analysis, hardware design, software design and overall testing. The test results of the DHT 11 temperature sensor can read the temperature and humidity index whose data is in the form of digital data and is displayed on the LCD. The PWM of the DC motor and the direction of rotation of the motor can be controlled using the DHT11 sensor. The keypad can control the direction of rotation of the servo motor so that students are expected to be able to provide authentication through a password with a keypad. Testing the module kit for data communication using the local network Testing the module kit for data communication using the local network is able to control the motor and relay even though there is still a delay in sending data this is due to the condition of the internet network at the time of testing. The overall test results work well. It is hoped that this module will encourage students to be able to create technological innovation applications based on embedded systems and IoT which will lead to the creation of technology among students.
A Design of Body Mass Index (BMI) and Body Fat Percentage Device Using Fuzzy Logic Irmalia Suryani Faradisa; Radimas Putra Muhammad; Dyah Ayu Girindraswari
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 2 (2022): May
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i2.7

Abstract

Nutritional status is something that should consider because it is related to the level of health. Poor health can lead to malnutrition and death. The purpose of this study is to create a tool with a system that can determine the value and category of Body Mass Index (BMI) automatically using fuzzy logic to maintain nutritional status. However, because BMI can only decide underweight or overweight, it is necessary to determine the fat percentage based on the British Journal of Nutrition. In determining BMI and fat percentage, a load cell weight sensor with a capacity of 200 kg as a bodyweight measurement, an ultrasonic sensor HCSR-04 as a body height measurement, and a keypad that functions to enter a name, age, gender, and type of activity data. Database in this system can provide and store easier and real-time data, so the data output is accessible directly. The results are analyzed by comparing the measurement with standard tools. The BMI test taken 5 times, showed that the categories in the system (very thin, thin, normal, heavy, obese) were the same as the MATLAB test and manual calculations. Meanwhile, the results of testing body fat percentage taken 4 times also show the same category as the Body Monitor tool. So, this system can use for daily to monitor the condition of nutritional status and fat percentage in real-time.
Prayer Guide Gyroscope Bracelet for The Deaf Using MPU6050 Sensor Heriyadi Heriyadi; Hanifah Rahmi Fajrin; Wisnu Kartika
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 1 (2022): February
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i1.6

Abstract

The majority of Indonesia's population is Muslim, including more than 13,000 people with hearing impairments. In carrying out congregational prayers, the Deaf find it difficult to follow the instructions of the Imam's movement. The presence of hearing aids cannot be used by all persons with hearing impairments, and hearing aids often cause a buzzing sound, thus disturbing concentration. Therefore, in this study, a gyroscope bracelet will be made to assist people with hearing impairments in following the instructions of the Imam's movement when carrying out congregational prayers. The bracelet worn by the Imam will send a code in the form of a change in angle to the bracelet used by the Deaf congregation. The Z angle is a vertical angle in the gyroscope where the Z angle has an angular velocity of 360 degrees per second. The control system uses Arduino nano FT232RL FTDI FT232. The communication module uses HC-12 SI4463, with a wireless frequency of 433.4 - 473.0 MHz. The sensor for detecting changes in motion is the MPU6050 gyroscope sensor, the vibration indicator uses a micro vibrator motor. The bracelet used by the deaf will read the code from the Imam's device, with a notification in the form of a different vibration on every change in prayer movement. After experimenting with 30 people, the percentage of success was 84% ​​for all prayer positions. Thus, the gyroscope bracelet tool for prayer guides for the Deaf can help the Deaf community in carrying out congregational prayers.
Validity of Electronic Device-Based Application for Visual Acuity Examination: A Systematic Review Natasya Febrilia Yulianti; Al Munawir; Novan K. Adji
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 1 (2022): February
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i1.7

Abstract

Recent years, advances in the internet and communication technology have enabled the proliferation of digital medical devices with innovations in health applications, including for visual acuity examination. However, the validity of these applications remains unclear. The limited mobility and health service during the COVID-19 pandemic underscores the urgent need to conduct research that validates these electronic device-based applications. Thus, this study aims to critically analyze whether the electronic device-based application can provide a valid and high-quality visual acuity examination. A systematic review was conducted through studies searching PubMed, MEDLINE, Springer, and Cochrane Library using specific keywords. After the studies were selected through inclusion and exclusion criteria, extraction was carried out. Publications from 2011 to the end of 2021 were reviewed, yielding in 1409 studies, of which 19 were included. The results showed a lower systematic bias for distance visual acuity testing with electronic device-based applications than standard reference tests with a mean difference of -0.08 to 0.10 logMAR. The validity of the near visual acuity examination with the application shows better results than the distance examination, which is marked by smaller 95% limits of agreement range. The results of the analysis of Bland-Altman plots in all the studies reviewed showed that the accuracy of the examination results tended to increase in patients who had better visual acuity. In practice, the use of electronic device-based applications for visual acuity examination can increase the work effectiveness of medical personnel and the proliferation of digital medical devices. It can also be one of the breakthroughs in remote medical services and support the implementation of telemedicine policies.
A Low Cost Electrosurgery Unit (ESU) Design with Monopolar and Bipolar Methods Bambang Guruh Irianto; Levana Forra Wakidi; Ade Ryan Endarta; Madeha Ishag Adam; Hafsa Aamir
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 2 (2022): May
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i2.1

Abstract

Surgery using a conventional scalpel causes the patient to lose a lot of blood; this needs to be avoided. The purpose of this research is to make a replacement for the conventional scalpel using a device that utilizes high frequency with a duty cycle setting that is centered at one point. The design of the device is equipped with monopolar and bipolar pulse selection with an increased frequency at 400 kHz, where the duty cycle of bipolar mode can be set to 100% on and the coagulation duty cycle is 6% on and 94% off. The power output of the module was tested using an ESU Analyzer, while cutting the bipolar forceps used soap and meat media. The power inverter circuit was set with the module impedance values ​​of 300Ω, 400Ω, and 500Ω. Power settings were set at high, medium, and low with 2 pulse cutting and coagulation modes. The average power resulted in the lowest power of 32.3Watt and the highest power cutting mode of 58.3Watt. Meanwhile, in the coagulation mode of the lowest power of 3Watt and the highest power of 3Watt, the impedance setting is 500Ω. The module can output power linearly according to settings and can cut media well. Furthermore, the development of making Electrosurgery design in this study is expected to facilitate the surgical process during the surgical procedures.

Page 7 of 12 | Total Record : 113