cover
Contact Name
Assoc. Prof, Dr Azriyenni
Contact Email
ijeepse@eng.unri.ac.id
Phone
+6276166596
Journal Mail Official
ijeepse@eng.unri.ac.id
Editorial Address
Kampus Bina Widya, Jl. HR. Soebrantas Km. 12.5 Panam, Pekanbaru, Riau, Indonesia 28293 Website : www.ijeepse.ejournal.unri.ac.id No. Telp/Faks : +62 761 66596 / 66596 Email: ijeepse@eng.unri.ac.id
Location
Kota pekanbaru,
Riau
INDONESIA
International Journal of Electrical, Energy and Power System Engineering (IJEEPSE)
Published by Universitas Riau
ISSN : -     EISSN : 26544644     DOI : 10.31258
The IJEEPSE is particularly concerned with the demonstration of applied science and innovative engineering solutions to solve problems on power, energy, wireless communication and, informatics. Original contributions providing insight into the use of renewable energy, power generation and smart transmission grids, energy conversation, communication, informatics and computer sciences.
Articles 111 Documents
Analysis Of Power Generation Photovoltaic Array 9×10 Wp Under Shading Effect Utami, Dwi Prima Putri; Rajagukguk, Antonius
International Journal of Electrical, Energy and Power System Engineering Vol. 3 No. 1 (2020): International Journal of Electrical, Energy and Power System Engineering (IJEEP
Publisher : Electrical Engineering Department, Faculty of Engineering, Universitas Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (534.009 KB) | DOI: 10.31258/ijeepse.3.1.13-16

Abstract

There are several problems that can interfere with the performance of large-scale PV. One that enhances PV performance is shading on a PV module, that make interferes PV performance. This research studied about the effect of shading on the performance of large-scale PV systems through testing a 9 × 10 Wp miniature PV array and simulation using Matlab software. The use of diodes on a PV module can be done to prevent damage to the PV module due to shading. Through the power-voltage (P-V) and current-voltage (I-V) characteristic curves the effect of shading and the use of bypass and blocking diodes can be determined. Shading effect gave in a decrease in power in the PV module. From the results of this study note that the bypass diode and blocking diode output power generated by the PV module can be optimal.
Analysis of SCADA Application on Distribution System Reliability Marpaung, Noveri Lysbetti; Ervianto, Edy; Amri, Rahyul; Illahi, Hayatul
International Journal of Electrical, Energy and Power System Engineering Vol. 3 No. 2 (2020): International Journal of Electrical, Energy and Power System Engineering (IJEEP
Publisher : Electrical Engineering Department, Faculty of Engineering, Universitas Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31258/ijeepse.3.2.46-52

Abstract

Reliability of Electrical Power Distribution to consumer is strongly influenced by its distribution system. Therefore, electrical power distribution system with high reliability is needed. In distribution of electrical power, reliability level of distribution system is very necessary, because it is influential strongly factor towards continuity of electrical energy distribution to consumers. Parameters can be used to determine reliability level of Electrical Power Distribution System are SAIDI, SAIFI, and CAIDI. SCADA on Electrical Power Ditribution System is needed because it can monitor, control, configure and record working system real time. Besides it, SCADA also can handle interruption temporary or permanently in short time by using remote. Aim of this research is to compare distribution system reliability indexes such as SAIFI, SAIDI and CAIDI before and after integrated with SCADA in Bukittinggi Rayon of PT PLN (Persero), Western Sumatera, Indonesia. This research uses Distribution System Data from 2015 and 2016. Result of this rresearch is Realibility Indexes before Integrated with SCADA(2015) are 15.40 hours/customer, 46.36 interruption/year, 0.33 hour/year, while after Integrated with SCADA(2016) are 2.14 hours/customer, 22.41 interruption/year, 0.10 hour/year. for SAIDI, SAIFI CAIDI Indexes respectivel y. It can be concluded that The increase of Reliability Index after integrated with SCADA are 86.1% for SAIDI, 51.66% for SAIFI, 69.7% for CAIDI.
Cryptography with Layered Algorithms for Text Security on Android Safrianti, Ery; Fitriansyah, Fernanda
International Journal of Electrical, Energy and Power System Engineering Vol. 3 No. 2 (2020): International Journal of Electrical, Energy and Power System Engineering (IJEEP
Publisher : Electrical Engineering Department, Faculty of Engineering, Universitas Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31258/ijeepse.3.2.35-39

Abstract

Android phone is one of the most widely used telecommunications devices today. The exchange of various forms of information ranging from text, sound, images and video through this media is inseparable from the threat of criminal crime through digital data theft. Data security aspects are very important to be considered, one of which is data in the form of text. Text data is commonly used in short message services (SMS), chat in various Android applications or in the use of logins and passwords. This research will create an application on Android for securing text data through cryptographic techniques with a layered algorithm using three types of algorithms namely Caesar, Blowfish and AES Algorithms (Advanced Standard Encryption). This application can run on Android 5.0 (lollipop) or above, which can be used to encrypt and decrypt text messages. The test results show that the results of the initial text that was encoded through the encryption process can be safely returned by the decryption process without the slightest mistake with the original text. The encryption test for capital letters, numbers, and punctuation can be completely decrypted.
The Characteristics of Five Ceramics and Two Granites as Solid Dielectrics for An Ozone Generator: The Characteristics of Five Ceramics and Two Granites as Solid Dielectrics for An Ozone Generator Murdiya, Fri; Hardiwika, Ericko
International Journal of Electrical, Energy and Power System Engineering Vol. 3 No. 2 (2020): International Journal of Electrical, Energy and Power System Engineering (IJEEP
Publisher : Electrical Engineering Department, Faculty of Engineering, Universitas Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31258/ijeepse.3.2.53-56

Abstract

The utilization of ozone is commonly applied in various fields, for instance, it is used as a disinfectant for water treatment, disinfecting, sterilizing medical devices and preserving foodstuffs. Ozone is a nearly colorless gas with a characteristic odor that can be detected by humans up to 0.01 ppm. It can be produced by the dielectric barrier discharge method,which is generally used as a method of generating ozone supplied by high voltage or also called high voltage plasma generators. High voltage plasma occurs in the dielectric barrier discharge air gap, as a result of the air failed in maintaining its insulator properties. The power supply used in this study is a parallel resonant pushpull inverter using a flyback transformer. Furthermore, this study did not use an additional magnetic loudspeaker and used ceramic dielectrics instead. 5 types of ceramics and 2 different types of granite and combined the range of air gap were used during examination and research. The research indicates that the best plasma was found in ceramics 3, 5, granite 1 and 2 with an air gap of 2mm. The current discharge in ceramic 1 with an air gap of 2 mm was higher than the others. The highest voltage discharge was on granite 2 with an air gap of 2 mm. Ceramics 3, 5, granite 1 and 2 with an air gap of 2mm had better ozone concentrations than ceramics 1, 2 and 4.
Decision Support System for Selecting University in Pekanbaru Based on Android Dewi Nasien; M. Hasmil Adiya; Mulyadi, Ahmad; Sukabul, Ahmad; Rianda, Gilang; Yulianti, Deni
International Journal of Electrical, Energy and Power System Engineering Vol. 3 No. 2 (2020): International Journal of Electrical, Energy and Power System Engineering (IJEEP
Publisher : Electrical Engineering Department, Faculty of Engineering, Universitas Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31258/ijeepse.3.2.30-34

Abstract

Nowadays development of technology is growing fast, especially Android Operating System (OS). Android is a technology that can help human to improve their works both quality and quantity, e.g. making decisions. This study discusses the application of decision support systems to select university. Many students are still confused to select the best university for them. Hence, this application aims to assist students for making decisions using weighted product (WP) method. It exploits some criteria namely, distance, university accreditation and number of lecturers. The research methodology are used namely problem analysis, analysis both hardware and software requirements, design system, implementation and testing. Ultimately, application can be utilized. This application is built on Android Studio and Java Development Kit. It is implemented in Universities in Riau. This application can help students to choose the best university quickly and accurately.
Case Service System at the Child Welfare Institution using the Case-Based Reasoning Method Gigih, Priyandoko; Andriani , Citra; Istiadi , Istiadi; Abd Wahab , Mohd Helmy
International Journal of Electrical, Energy and Power System Engineering Vol. 3 No. 2 (2020): International Journal of Electrical, Energy and Power System Engineering (IJEEP
Publisher : Electrical Engineering Department, Faculty of Engineering, Universitas Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31258/ijeepse.3.2.40-45

Abstract

The Child Social Welfare Institution (LKSA) is an institution tasked with providing relief services to meet the standards of living, health, education, and the social needs of both individuals and groups. An LKSA Robbani is one of the institutions that help in handling family and child cases by National Standards for Child Care. In solving child problems, the institution must open the previous case data to determine the appropriate solution, such that the service process becomes long. Therefore, an application software is needed that can help the institution to be faster. The developed system is using the Case-Based Reasoning (CBR) Method. The advantage of this method is how to adapt the solutions of the previous case, as well as in seeking similarity in each case that the most significant similarity value is considered the most similar case. The method is very suitable for building the application. The system that was built had to do a trial before being used by the user. The trial result was carried out of the system with manual calculations using the case-based reasoning method. Furthermore, from the results of the trial, it was produced by 87.5%.
Performance Analysis of DSR and TORA Model Routing Protocols In Vehicular Ad Hoc Network Sari, Linna Oktaviana; Azmi, Agusurio; Safrianti, Ery; Jalil, Feranita
International Journal of Electrical, Energy and Power System Engineering Vol. 3 No. 3 (2020): International Journal of Electrical, Energy and Power System Engineering (IJEEP
Publisher : Electrical Engineering Department, Faculty of Engineering, Universitas Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31258/ijeepse.3.3.94-99

Abstract

Pekanbaru city is a large area, therefore traffic congestion often occurs due to the density of society’s vehicles. From this problem, it is needed a technology that can exchange information between vehicles. Information Technology that can involve many vehicles with special network types without dependence on an infrastructure is Ad Hoc Network. One type of this network is Vehicular Ad Hoc Network (VANET). VANET is a new concept in enabling communication between Vehicle to Vehicle (V2V). For efficient data packet delivery, VANET requires a routing protocol. In this research, for simulated and analyzed performance is used the Dynamic Source Routing (DSR) and Temporally Ordered Routing Algorithm (TORA) protocol. NS-2 is used to simulated a moved nodes, SUMO software is used to simulated real map of SKA Mall crossroad and parameter the quality of performance routing protocol DSR can determined by End to End Delay, Packet Delivery Ratio (PDR) and Routing Overhead (RO). This simulation uses scenario 100 nodes, 150 nodes, 200 nodes and 250 nodes. The simulation results with the scenario of changing the number of nodes, the DSR routing protocol produces better performance with an average of End to End Delay is 0.1066 s, average of PDR is 95.45% and average of RO is 1.0076. While the TORA routing protocol has an average of End to End Delay is 0.1163s, average of PDR is 93.49% and average of RO is 1.0801. And in the scenario of node speed changes, the TORA routing protocol produces better performance with an average of End to End Delay is 0.0861 s and average of PDR 97.37%. While the DSR routing protocol is better with an average of RO is 1.0076.
Optimization of PV Power Capacity of 10 KWp Capacity Based on P&O Algorithm and Boost Converter Rajagukguk, Antonius; Aritonang, Maryani
International Journal of Electrical, Energy and Power System Engineering Vol. 3 No. 3 (2020): International Journal of Electrical, Energy and Power System Engineering (IJEEP
Publisher : Electrical Engineering Department, Faculty of Engineering, Universitas Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31258/ijeepse.3.3.57-64

Abstract

Using solar panels as a power plant can reduce the dependence of fuel oil. To work always on maximum power points (MPP), Photovoltaic (PV) requires optimization method. Therefore, the authors are interested in discussing the optimization method of the PV array model using Maximum Power Point Traking (MPPT) with the Perturbation & Observation (P & O) Algorithm and Boost Converter. In this case, PV capacity will be simulated on 10 kWp. That PV consists of 4 strings, which is each strings consist of 10 PV modules. The output of PV modules will be forwarded to the Boost Converter circuit. Boost Converter want is controlled by P&O Algorithm. The voltage and current generated from the PV array modeling will be used by the P&O Algorithm as a reference. The function of P&O Algorithm is to track the Maximum Power Point (MPP) of the PV model. The result of tracking power by P&O Algorithm will be forwarded to Pulse Width Modulation (PWM) circuit as a duty cycle generator. Duty cycle signal will be forwarded to the switching tool contained in the converter circuit. By that control system, PV model expected has maximum power according to the voltage. Based on the results of power test by 1000 W/m2 radiation, maximum power obtained is equal to 9967 Wp with 99.6 % efficiency at a voltage level of 400 volt. Therefore,it can be concluded that the design of the PV Array System using P&O Algorithm and the Boost Converter can work well.
Analysis of Lightning Performance on 345 kV Transmission Lines Using Python Programming: Analysis of Lightning Performance on 345 kV Transmission Lines Using Python Programming Murdiya, Fri; Hariadi, Rofi
International Journal of Electrical, Energy and Power System Engineering Vol. 3 No. 3 (2020): International Journal of Electrical, Energy and Power System Engineering (IJEEP
Publisher : Electrical Engineering Department, Faculty of Engineering, Universitas Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31258/ijeepse.3.3.65-76

Abstract

One of main causes of interruption of electrical power supply is the lightning strike on overhead power transmission lines. The lightning performance of transmission line can be determined by value of shielding failure flashover rate (SFFOR) and back flashover rate (BFOR). The object of this study is to create a computer application to compute lightning performance on the transmission lines using Python programming. Pythons package tkinter used for program interface window. Application programming is done by using the concept of object-oriented programming (OOP) using Pythons keyword class. Validation shows that the application has applied the method correctly with a percentage error 0 % for SFFOR and 3.14 % for BFOR. The application can do analysis on the factors that affecting SFFOR and BFOR such as the effect of thunder day, tower foot resistance, and number of isolator disk. The results obtained in this study is computer application that can perform lightning performance analysis and analysis of factors that can affect it, such as thunder day, tower foot resistance and the number of isolator disk.
Discovery Routing Time Speed Comparison of AODV, OLSR and ZRP protocols on MANET Safrianti, Ery; Oktaviana Sari, Linna; Rahayu, Tulus
International Journal of Electrical, Energy and Power System Engineering Vol. 3 No. 3 (2020): International Journal of Electrical, Energy and Power System Engineering (IJEEP
Publisher : Electrical Engineering Department, Faculty of Engineering, Universitas Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31258/ijeepse.3.3.100-106

Abstract

Mobile Ad hoc Network (MANET) is a wireless network that contains a collection of nodes without infrastructure and interconnected to communicate. MANET works dynamically when a group of nodes moves spontaneously, so the network topology can change quickly and cannot be predicted. It causes changes in wireless network topology according to existing conditions. The node functions in determining the route to be selected. Ad Hoc networks have limited transmission range, so routing is needed to send data over the network. The problem with mobile nodes is that routing must provide a path when the node changes. The speed of a node obtaining information is affected by the routing protocol used in the network. Each routing protocol has different capabilities in network speed, so the discovery routing time for each routing is also different. The selected routing protocols are Ad Hoc On-Demand Distance Vector (AODV), Optimized Link-state (OLSR), and Zone Routing Protocol (ZRP). The study will conduct a comparative analysis of ad hoc network initialization speeds on AODV, OLSR, and ZRP routing protocols. The parameter tested is the speed of routing discovery. After the data is collected, an analysis is carried out by looking at the routing discovery speed of each routing protocol. The test results show that each of the routing protocols examined, the AODV routing protocol, has a faster routing discovery time than the OLSR and ZRP routing protocols.

Page 4 of 12 | Total Record : 111


Filter by Year

2018 2025


Filter By Issues
All Issue Vol. 8 No. 3 (2025): The International Journal of Electrical, Energy and Power System Engineering (I Vol. 8 No. 1 (2025): The International Journal of Electrical, Energy and Power System Engineering (I Vol. 7 No. 2 (2024): The International Journal of Electrical, Energy and Power System Engineering (I Vol. 7 No. 1 (2024): The International Journal of Electrical, Energy and Power System Engineering (I Vol. 6 No. 3 (2023): The International Journal of Electrical, Energy and Power System Engineering (I Vol. 6 No. 2 (2023): The International Journal of Electrical, Energy and Power System Engineering (I Vol. 6 No. 1 (2023): The International Journal of Electrical, Energy and Power System Engineering (I Vol. 5 No. 3 (2022): The International Journal of Electrical, Energy and Power System Engineering (I Vol. 5 No. 2 (2022): International Journal of Electrical, Energy and Power System Engineering (IJEEP Vol. 5 No. 1 (2022): International Journal of Electrical, Energy and Power System Engineering (IJEEP Vol. 4 No. 3 (2021): International Journal of Electrical, Energy and Power System Engineering (IJEEP Vol. 4 No. 2 (2021): International Journal of Electrical, Energy and Power System Engineering (IJEEP Vol. 4 No. 1 (2021): International Journal of Electrical, Energy and Power System Engineering (IJEEP Vol. 3 No. 3 (2020): International Journal of Electrical, Energy and Power System Engineering (IJEEP Vol. 3 No. 2 (2020): International Journal of Electrical, Energy and Power System Engineering (IJEEP Vol. 3 No. 1 (2020): International Journal of Electrical, Energy and Power System Engineering (IJEEP Vol. 2 No. 3 (2019): International Journal of Electrical, Energy and Power System Engineering (IJEEP Vol. 2 No. 2 (2019): International Journal of Electrical, Energy and Power System Engineering (IJEEP Vol. 2 No. 1 (2019): International Journal of Electrical, Energy and Power System Engineering (IJEEP Vol. 1 No. 2 (2018): International Journal of Electrical, Energy and Power System Engineering (IJEEP Vol. 1 No. 1 (2018): International Journal of Electrical, Energy and Power System Engineering (IJEEP More Issue