cover
Contact Name
Danang
Contact Email
lpkdgeneration2022@gmail.com
Phone
+6285726173515
Journal Mail Official
danang@stekom.ac.id
Editorial Address
Jln. Senopati Arcawinagun Purwokerto 53113 Telp (0281) 6572636 Purwokerto 53121 Tlp. (0281) 6577111, 575222, 6575333,
Location
Kab. banyumas,
Jawa tengah
INDONESIA
Jurnal Ilmu Kedokteran dan Kesehatan Indonesia
ISSN : 28278488     EISSN : 2827797X     DOI : 10.55606
Core Subject : Health,
Jurnal Ilmu Kedokteran dan Kesehatan Indonesia diterbitkan 3 kali dalam setahun, yaitu pada bulan Maret, Juli dan November. Jurnal Ilmiah Kedokteran dan Kesehatan Indonesia menyajikan hasil penelitian yang bermanfaat bagi dokter, pengambil kebijakan, tenaga kesehatan, dosen serta mahasiswa yang tertarik dengan publikasi ilmiah terkait Ilmu Kedokteran dan Kesehatan
Articles 206 Documents
Perbandingan Hasil Radiografi Efusi Pleura Pada Proyeksi Right Lateral Decubitus (RLD) Dan Left Lateral Decubitus (LLD) Pada Klinis Dengue Haemoragic Fever (DHF) Di RSU. Wisata Universitas Indonesia Timur Akhmadi Akhmadi; Rini Hatma Rusli; Muhamad Rudiansyah; Amelia Niwele; Yohannes Hursepunny
Jurnal Ilmu Kedokteran dan Kesehatan Indonesia Vol. 2 No. 2 (2022): JULI : Jurnal Ilmu Kedokteran dan Kesehatan Indonesia
Publisher : Pusat Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/jikki.v2i2.4171

Abstract

Dengue Hemorrhagic Fever (DHF) is an infectious disease that can be fatal in a relatively short time. This disease is classified as "difficult to differentiate" from other dengue fever diseases. If without quick and appropriate treatment, the sufferer could fall into an even more fatal condition. And generally the supporting action taken is an X-ray examination of the chest to assess the presence of fluid in the pleura as a result of the Aedes Aegypti mosquito virus. The purpose of this research is to know the Comparison of Radiographic Results of Pleura Effusion on Right Lateral Decubitus Projection and LLD ( Left Lateral Decubitus ) in DHF ( Dengue Haemoragic Fever ) case. This research was conducted in RSU.Wisata Radiology installation of Universitas Indonesia Timur with quantitative research method with experimental design approach. Data collection is done by finding literature, observation, interview, and documentation. From the results of the research that the image of pleural effusion with RLD projection ( Right Lateral Decubitus ) shows better radiographic picture in assessing the level of pleural effusion with clinical DHF ( Dengue Haemoragic Fever ).
Pengaruh Variasi Nilai mA (Mili Ampere) dan s (Second) yang Berbeda Dengan Nilai mAs yang Sama Terhadap Paparan Medik yang Diterima Pasien Maritje S. J. Malisngorar; Ira Sandi Tunny; Amelia Niwele; Akhmadi Rini Hatma Rusli; Iksan Soumena; Bambang Ariyanto
Jurnal Ilmu Kedokteran dan Kesehatan Indonesia Vol. 2 No. 2 (2022): JULI : Jurnal Ilmu Kedokteran dan Kesehatan Indonesia
Publisher : Pusat Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/jikki.v2i2.4172

Abstract

This study aims to find out how to measure exposure dose medical techniques which accepted the patients with a variety of ma and s at the same mas value and the effect of variations in the value of mili ampere and second different with the same mas value to medical exposure dose received by patients. This type of study is an observational descriptive with the approach of the experimental or trial. using gauges medic exposure dose, x-ray multimeter with research indicator mili ampere and second are different but the same mas. From these results it can be concluded the highest medical exposure dose received by patients is the variation of 200 ma and 0.05 s with a dose value of 5.533 mgy / s. this is due to the amount of flow tube (ma). it can be concluded that the greater ma is used, the greater the dose the patient received medical.
Literature Review Dosis Radiasi pada Pemeriksaan Radiografi Thorax Anak Akhmadi Akhmadi
Jurnal Ilmu Kedokteran dan Kesehatan Indonesia Vol. 2 No. 3 (2022): NOVEMBER : Jurnal Ilmu Kedokteran dan Kesehatan Indonesia
Publisher : Pusat Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/jikki.v2i3.4173

Abstract

Thorax radiology examination in children is one of the most frequently performed examinations in hospitals. However, the radiation used in this examination can potentially disrupt the growth and function of the child's imperfect organs. Therefore, patient radiation protection is very important to optimize the radiation dose received. The Nuclear Energy Regulatory Agency (BAPETEN) has set reference level values ​​in the form of IDRL (Indonesia Reference Level) for Diagnostic Radiology, including CT-Scan, Mammography and Fluorescence, as well as DRL (Diagnostic Reference Level) values ​​for children's thorax. The radiation dose received by the patient must be considered to avoid negative effects on the child's growth. This study aims to determine the measurement of radiation dose on chest radiography examinations of children. In this study, we will compare the radiation dose received by pediatric thorax patients based on the radiation dose standards set by UNSCEAR in 2000. Apart from that, we will also compare the radiation dose received by pediatric thorax patients with other studies. It is hoped that the results of this research will provide useful information and input for hospital diagnostic services in optimizing the radiation dose received by pediatric patients.
Literature Review Kesehatan dan Keselamatan Kerja Pelayanan Radioterapi pada Penggunaan Pesawat Linac Ira Sandi Tunny; Rini Hatma Rusli; Maritje S. J. Malisngorar; Iksan Soumena; Miranda Waas
Jurnal Ilmu Kedokteran dan Kesehatan Indonesia Vol. 2 No. 2 (2022): JULI : Jurnal Ilmu Kedokteran dan Kesehatan Indonesia
Publisher : Pusat Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/jikki.v2i2.4174

Abstract

Occupational Health and Safety are conditions in work that are healthy and safe, both for the job, the company and for the community and environment around the factory or workplace. One of the K3 Standards according to the Ministry of Health as intended in paragraph (1) is aimed at preventing and reducing occupational diseases and other illnesses, as well as work accidents among employees, and creating safe, comfortable and efficient offices to encourage work productivity.The research method used in this research is library research which uses literature as the main object. This research carried out descriptive analysis, namely trying to describe the Occupational Health and Safety of Radiotherapy services when using LINAC aircraft. To find out Occupational Health and Safety in Radiotherapy services, researchers reviewed several literature including books, articles and journals related to Occupational Health and Safety in Radiotherapy services in several hospitals in Indonesia. The research results show that creating occupational health and safety in radiodiagnostic and radiotherapy services requires component compatibility. Good equipment, examination room design that complies with the rules, appropriate procedures, security systems, health monitoring of officers and policies from the highest responsible persons.
Prosedur Pemeriksaan Dacryocystografi Pada Kasus Dacryosistitis Kronis Di Instalasi Radiologi RSUP. Dr.Wahidin Sudirohusodo Makassar Bambang Ariyanto; Rini Hatma Rusli; Akhmadi Akhmadi; Miranda Waas; Amelia Niwele
Jurnal Ilmu Kedokteran dan Kesehatan Indonesia Vol. 2 No. 3 (2022): NOVEMBER : Jurnal Ilmu Kedokteran dan Kesehatan Indonesia
Publisher : Pusat Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/jikki.v2i3.4175

Abstract

Dacryocystography examination is the examination of the radiologist to show the nasolacrimal duct by using a positive contrast medium. The purpose of this examination is to describe the system of tear duct blockage and the level of blockage. This research method is descriptive with aproachcase study conducted in RSUP. Dr. WahidinSudirohusodo Makassar on Juni 2019. The inspection technique is done by using the projection Antero Posterior (AP), which contrast material is inserted throught the tear duct in the lacrimal punctum which empties into the concha nasalis inferior. From the result of the examination has been done, it can be concluded that the contrast as much as 1 cc inserted throught the superior lacrimal punctum, contrast restrained and spilled out. Contrast as much as 1 cc inserted throught the inferior lacrimal punctum, the contrast seems to fill out the inferior palpebra area. From the research, lacrimal duct obstruction impression superior and inferior.
Perbandingan Kualitas Citra Radiograf Kepala Menggunakan Grid dan Tanpa Grid pada Computed Radiografi Rini Hatma Rusli; Ira Sandi Tunny; Maritje S. J. Malisngorar; Akhmadi Akhmadi; Yohannes Hursepunny
Jurnal Ilmu Kedokteran dan Kesehatan Indonesia Vol. 2 No. 2 (2022): JULI : Jurnal Ilmu Kedokteran dan Kesehatan Indonesia
Publisher : Pusat Riset dan Inovasi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55606/jikki.v2i2.4176

Abstract

One factor that plays an important role in the quality of radiodiagnostic examination results is radiographic contrast. When examining thick objects, radiographic contrast will decrease as a result of the large amount of scattered radiation originating from the object and reaching the film. To obtain optimal radiographic contrast on thick objects such as the head, it can be done in various ways, including using a grid. The grid is a tool that functions to absorb scattered radiation but can still transmit primary radiation. Examination of the head is done to get the head radiograph and to determine any abnormalities or diseases of the head. This examination was performed using the grid and without grid to compare the better results of radiographs. Radiographs results were obtained using processing film, Computed Radiography (CR). This research used descriptive study conducted at Hospital Tk. II Pelamonia Makassar on January 2020. Based on the results of the research which conducted for examination of the head using grid and without grid on CR cassette obtained that the result of radiograph examination of the head using a grid was better.