cover
Contact Name
Kusdiantoro Mohamad
Contact Email
kusdiantoro@apps.ipb.ac.id
Phone
-
Journal Mail Official
currbiomed@apps.ipb.ac.id
Editorial Address
Jalan Agatis, Kampus IPB Dramaga, Bogor 16680, Jawa Barat, Indonesia
Location
Kota bogor,
Jawa barat
INDONESIA
Current Biomedicine
ISSN : 29628490     EISSN : 29854784     DOI : https://doi.org/10.29244/currbiomed
Core Subject : Health, Science,
Aim. Current Biomedicine aims to publish scientific article in the biomedical fields. Scope. Current Biomedicine will publish widely relevant topic in the field of biology (life science), directly or indirectly, support the improvement of human health. These fields include, but are not limited to: anatomy, physiology, histology, embryology, genetics, pharmacology, toxicology, pharmacy, parasitology, pathology, microbiology, clinics, radiology and imaging, surgery, experimental surgery, reproduction, ethnomedicine, phytopharmaceuticals, biotechnology, biomedical engineering, bioinformatics, public health, epidemiology, legislation and bioethics, and one health.
Articles 64 Documents
Front Matter Vol 4 No 2 Current Biomedicine
Current Biomedicine Vol. 4 No. 2 (2026): July
Publisher : School of Veterinary Medicine and Biomedical Sciences, IPB University, Bogor, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Preliminary comparison of respiratory rate estimation methods using simultaneous dual- position under-mattress millimeter-wave radar Masanobu Tsurumoto
Current Biomedicine Vol. 5 No. 1 (2027): January (In Progress)
Publisher : School of Veterinary Medicine and Biomedical Sciences, IPB University, Bogor, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29244/currbiomed.5.1.1

Abstract

Background Under-mattress millimeter-wave radar may provide unobtrusive respiratory sensing, but signal morphology can vary with sensor position and estimation method. This study aimed to compare frequency-domain and time-domain respiratory rate estimation using simultaneous dual-position under-mattress radar measurements. Methods Three healthy adult volunteers underwent supine instructed breathing at 10, 12, and 15 breaths/min. Two XM125 60-GHz-class radar modules were operated simultaneously beneath an 8-cm non-coil medical mattress at positions aligned with the sternal angle and xiphoid process. Each condition was repeated three times, yielding 27 paired trials and 54 radar recordings. The respiratory rate was estimated using a power spectral density method and time-domain peak detection. Mean absolute error, root mean square error, paired position differences, and exploratory harmonic characteristics of peak-detection failures were examined. Results Estimation based on power spectral density yielded a mean absolute error of 0.472 breaths/min and a root mean square error of 0.479 breaths/min, compared with 1.710 and 2.250 breaths/min for peak detection. The mean paired difference between sensor positions was +0.037 breaths/min for power spectral density estimation and +0.164 breaths/min for peak detection. Power spectral density estimates differed by no more than 0.05 breaths/min in 26 of 27 paired trials. Recordings with peak-detection errors greater than 1.0 breaths/min showed higher second- and third-harmonic ratios. Conclusion Under controlled instructed-breathing conditions, power spectral density-based estimation showed smaller deviations from the instructed breathing rates than simple peak detection, whereas the two positions generally yielded similar frequency-domain estimates. These findings are technical results relative to instructed breathing rates and do not constitute clinical validation.
Design-consistent statistical learning for rare survey outcomes: a cardiovascular-kidney-metabolic multimorbidity plasmode benchmark in women Sunday A Adetunji; Rhoda O Oyewusi; Tomiisin Balogun; Bukola Adetunji; Oluwatimileyin C Adetunji
Current Biomedicine Vol. 5 No. 1 (2027): January (In Progress)
Publisher : School of Veterinary Medicine and Biomedical Sciences, IPB University, Bogor, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29244/currbiomed.5.1.7

Abstract

Background Cardiovascular-kidney-metabolic (CKM) disease integrates metabolic, renal, and cardiovascular systems. Learning in probability samples is challenged by rare outcomes, unequal sampling, clustered dependence, and miscalibration. This study aimed to develop a design-consistent, calibration-first framework for concurrent CKM multimorbidity classification in complex surveys and quantify the consequences of ignoring survey design. Methods We analyzed the National Health and Nutrition Examination Survey (NHANES) 2017–March 2020 data for U.S. women aged 20–44 years. CKM multimorbidity was defined as the coexistence of at least two of the following: hypertension, diabetes mellitus, chronic kidney disease, and clinical cardiovascular disease. Five learners were compared using 20×5 whole-PSU design-aware cross-validation, fold-contained preprocessing, survey-weighted loss functions, and cross-fitted sigmoid recalibration. The evaluation used design-based and survey-bootstrap procedures across key performance metrics. A 6,000-replicate survey-plasmode benchmark was used to evaluate bias, RMSE, and 95% coverage against finite-population truth. Results Among 1,743 classifiable women, 44 unweighted cases yielded a survey-weighted prevalence of 1.97% (95% CI, 1.30%–2.65%). The elastic net minimized the calibrated weighted log loss (0.089) and achieved a ROC AUC of 0.797 (95% CI, 0.765–0.830), PR AUC of 0.062 (0.023–0.100), and calibration slope of 0.90. Naive random cross-validation yielded an absolute log-loss bias of 0.0539 and 30.2% coverage; weighted design-aware cross-validation with recalibration achieved 95.0% coverage. Conclusion For rare CKM outcomes in complex surveys, valid population-level performance estimation requires survey-aware resampling, proper scoring rules, cross-fitted calibration, and design-consistent uncertainties. The framework distinguishes investigator-defined multimorbidity from guideline-aligned CKM staging.
Serum circITCH and lncRNA HOTAIR expression signatures: Novel diagnostic and metastatic biomarkers for colorectal cancer Aghras S. Nawar; Eman Redha Omran
Current Biomedicine Vol. 5 No. 1 (2027): January (In Progress)
Publisher : School of Veterinary Medicine and Biomedical Sciences, IPB University, Bogor, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29244/currbiomed.5.1.24

Abstract

Background Colorectal cancer (CRC) remains one of the leading causes of death worldwide because of its late detection which results from being asymptomatic in the early stages and poor adherence to the invasive screening procedure such as colonoscopy. The existing biomarkers used in the blood for early detection of this disease include carcinoembryonic antigen (CEA) and carbohydrate antigen 19-9 (CA19-9), but they have poor sensitivity. Non-coding RNAs have proven to be key epigenetic factors for CRC progression and metastasis, including circular RNA ITCH (circITCH) and long non-coding RNA HOTAIR (lncRNA-HOTAIR). Methods In a case-control study on 200 subjects (120 CRC patients and 80 healthy controls) whose specimens were histopathologically confirmed, the expressions of circITCH and lncRNA-HOTAIR were analyzed using qRT-PCR along with CEA and CA19-9. There were conducted clinicopathological correlations, ROC curves and multiple logistic regression analysis. Results Serum levels of circITCH were significantly lower in CRC patients than in healthy control group (0.54 ± 0.24 vs. 1.03 ± 0.31, P<0.001), whereas the level of lncRNA-HOTAIR was significantly higher (3.21 ± 1.38 vs. 1.06 ± 0.42, P<0.001). The individual AUCs of the biomarkers HOTAIR and circITCH were 0.941 (95% CI: 0.909–0.974) and 0.889 (95% CI: 0.840–0.938), respectively. The combined panel (circITCH + lncRNA-HOTAIR) showed superior diagnostic efficacy with the highest AUC of 0.969 (95% CI: 0.947–0.990; sensitivity= 93.3%; specificity= 91.3%), surpassing significantly the traditional protein biomarkers. Conclusion Circulating levels of circITCH + lncRNA-HOTAIR display complementary expression profiles and, when combined serve as effective, minimally invasive diagnostic biomarkers for CRC.