cover
Contact Name
Rudy Kurniawan
Contact Email
rudy14k@gmail.com
Phone
+6285267099660
Journal Mail Official
rudy14k@gmail.com
Editorial Address
Kampus Terpadu Balunijuk, Kecamatan Merawang, Kabupaten Bangka, Provinsi Kepulauan Bangka Belitung
Location
Kab. bangka,
Kepulauan bangka belitung
INDONESIA
Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering)
ISSN : 23555068     EISSN : 26224852     DOI : https://doi.org/10.33019/jurnalecotipe
This scientific journal is called Jurnal Ecotipe (Electronic, Control, Telcommunication, Information, and Power Engineering) with clusters of science in the field of Electrical Engineering covering the field of Electronics, Control, Telecommunications, Information/Informatics, and Power Electricity. The schedule of scientific journal publication is planned 2 times / volume in a year, ie April and October. The author can come from institutions outside the Department or from within the Department of Electrical Engineering University of Bangka Belitung. Aim and Scope : Electronics, Electronic Materials, Microelectronic System, Control System Engineering, Instrumentation and Control Engineering, Robotics, Telecommunication, Modulation and Signal Processing, Antenna and Wave Propagation, Information Technology, Information Theory and Coding, Computer Engineering and Informatics, Electrical and Power Engineering, Transmission and Distribution, Renewable Energy.
Articles 235 Documents
Performance Comparison of RTL-SDR and HackRF as ADS-B Signal Receivers at 1090 MHz Sholihin Sholihin; Siswandi; Eka Susanti; Herman Yani; Sopian Soim; Hotmauli Gracia Simatupang
Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering) Vol 13 No 2 (2026): Jurnal Ecotipe, October 2026
Publisher : Jurusan Teknik Elektro, Universitas Bangka Belitung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33019/jurnalecotipe.v13i2.4620

Abstract

The development of Software Defined Radio technology enables flexible reception and analysis of communication signals using software-based devices. One of its applications is the Automatic Dependent Surveillance-Broadcast (ADS-B) system, which operates at a frequency of 1090 MHz to digitally transmit flight information. This compare the performance of RTL-SDR and HackRF in receiving ADS-B signals at 1090 MHz. The research was conducted using an experimental method by testing both SDR devices under the same testing conditions and configurations. Signal reception was performed using SDR software and ADS-B decoding software to obtain flight data that could be successfully received and decoded. The test results were used to evaluate the capability of each device to receive and display ADS-B data at 1090 MHz. Based on the experimental results, both devices were capable of receiving ADS-B signals at 1090 MHz but exhibited different performance characteristics. These differences were influenced by device capabilities, receiver configurations, and environmental conditions during signal reception. RTL-SDR offers advantages in terms of cost and ease of use, while HackRF provides greater device flexibility for signal configuration and testing. The results indicate that both devices can be utilized as ADS-B signal receivers, with device selection depending on the specific requirements and intended application. Expected to serve as a reference for the use of SDR devices in receiving and monitoring ADS-B signals at 1090 MHz.
Optimal Solar PV Capacity Planning in Bangka Power System Using Grey Wolf Optimizer Wahri Sunanda; Rika Favoria Gusa; Euis Asriani; Firlya Rosa
Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering) Vol 13 No 2 (2026): Jurnal Ecotipe, October 2026
Publisher : Jurusan Teknik Elektro, Universitas Bangka Belitung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33019/jurnalecotipe.v13i2.4624

Abstract

This study develops a simplified optimization-based framework to determine the optimal Solar Photovoltaic (PV) capacity for the Bangka power system by combining an annual cost-minimization model with the Grey Wolf Optimizer (GWO). Annual electricity demand is supplied by PV and system-level fossil-based generation, while total annual cost comprises annualized PV investment, PV operation and maintenance (O&M), and fossil generation costs. Three scenarios are evaluated: a baseline without PV, a fixed-PV capacity of 50 MW, and a GWO-optimized PV capacity bounded between 0 and 150 MW. The calculations and GWO procedure are implemented in Python 3.10 using 30 wolves, 100 iterations, and 20 independent runs. All runs converge to the upper feasible capacity of 150 MW. At this capacity, PV generation reaches 236.52 GWh/year, representing 15.6% of annual electricity demand, compared with 78.84 GWh/year or 5.2% in the fixed-PV scenario. Fossil generation cost decreases from 181.73 to 153.35 million USD/year. After including 13.75 million USD/year in annualized PV investment and 2.25 million USD/year in PV O&M costs, the total annual system cost reaches 169.35 million USD/year, yielding net savings of approximately 12.38 million USD/year relative to the baseline. Annual CO2 emissions decrease from 1211.54 to 1022.32 ktCO2/year, corresponding to a reduction of approximately 189.22 ktCO2/year. Within the adopted annual model assumptions, the 150 MW configuration provides the lowest cost and emissions among the evaluated alternatives and represents a boundary optimum.
Evaluation of STIESIA E-Learning User Experience Using User Experience Questionnaire in the Implementation of Blended Learning Achmad Fakhri Dzulfiqar
Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering) Vol 13 No 2 (2026): Jurnal Ecotipe, October 2026
Publisher : Jurusan Teknik Elektro, Universitas Bangka Belitung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33019/jurnalecotipe.v13i2.4626

Abstract

This study evaluates user experience (UX) of STIESIA Surabaya’s e-learning platform within its blended learning program, with the aim of identifying specific strengths and gaps. Using a quantitative descriptive-evaluative design, researcher distributed User Experience Questionnaire (UEQ) to 90 Accounting and Management students, each with at least one semester of platform use. After screening 96 initial submissions, researcher analyzed 90 verified responses against a UEQ benchmark of more than 20.000 products. All six dimensions scored positively in absolute terms.  Perspicuity rated highest (1.33 Above Average), followed by Attractiveness (1.20) and Efficiency (1.13), and Stimulation (1.13), all above average. Dependability (1.00) and Novelty (0.43) fell Below Average against benchmark. An independent t-test found no significant differences between programs. Platform handles core pragmatic tasks well but shows relative weakness in novelty and dependability, which points to a need for user-centered investigation before any institution-wide redesign.
Design and Development of a Smart Energy Management System Based on Hybrid Demand Side Management For 1100 Wp Off Grid Solar Power Plant Battery Optimization Rivael Glenvil; Henry Candra; Dianing Novita Nurmala Putri
Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering) Vol 13 No 2 (2026): Jurnal Ecotipe, October 2026
Publisher : Jurusan Teknik Elektro, Universitas Bangka Belitung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33019/jurnalecotipe.v13i2.4632

Abstract

Off-Grid solar power plant systems often face battery life degradation due to deep discharge cycles. This research aimed to design a Smart Energy Management System (SEMS) based on an ESP32 microcontroller and PZEM-017 sensors to monitor and control load dispatch. The system supplied a 3,420 Wh daily load using 1,100 Wp solar panels and a 25.6V 100Ah (2,560 Wh) LiFePO4 battery. The applied strategy was Hybrid Demand Side Management (DSM), integrating Load Shifting and Load Shedding. Test results indicated the sensors operated exceptionally well with an average error rate of 1.44%. The system successfully executed Load Shifting by directly powering heavy loads during abundant solar production . Conversely, it executed priority Load Shedding by disconnecting non-essential loads during power-saving mode . Furthermore, the system automatically switched the power source to the utility grid when the battery reached a critical condition . The evaluation proved this system effectively prevented 100% deep discharge and limited the maximum Depth of Discharge (DoD) to 80%, significantly extending the LiFePO4 battery's cycle life.
Intelligent Mobile-Spatial System for Small Business Digital Innovation in Lubuk Linggau A Taqwa Martadinata; Joni Karman; Herman Paleni; Aptrilia Nadiella; Ariel Pratama
Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering) Vol 13 No 2 (2026): Jurnal Ecotipe, October 2026
Publisher : Jurusan Teknik Elektro, Universitas Bangka Belitung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33019/jurnalecotipe.v13i2.4636

Abstract

Micro, small, and medium enterprises (MSMEs) in Lubuklinggau City face digitalization barriers caused by the absence of an integrated, location-based business database and an objective basis for prioritizing digitalization programs. This study designed, built, and tested a mobile- and spatial-based information-system prototype integrating a Geographic Information System, a mobile-first responsive web application, and a Simple Additive Weighting (SAW)-based decision-support module with five digital-readiness criteria, deployed and populated with 50 MSME records across six sub-districts (about 0.51% of the 9,746 MSMEs on the city’s official business portal). Three kinds of evidence are reported separately: computational verification, in which system-generated preference values agreed exactly with an independent manual recalculation for all 50 records; software testing, in which 18 functional cases and 8 role-based access-control scenarios passed after two defects found in development-team testing were corrected and re-verified; and preliminary, non-generalizable feedback from a single development-team respondent. Because the active weights are an unelicited uniform placeholder, a sensitivity analysis recomputed rankings under four alternative weight scenarios: 66% of MSMEs changed maturity class under at least one scenario, and one cost-priority scenario retained only 2 of the baseline top-10 MSMEs, showing that the ranking is materially sensitive to weight choice. These results demonstrate implementation correctness and functional behavior under the tested conditions; they do not establish the criteria, weights, or thresholds as a validated policy instrument, nor system-wide technical readiness, both requiring further evaluation described in the conclusion.