cover
Contact Name
Triwiyanto
Contact Email
triwiyanto123@gmail.com
Phone
+628155126883
Journal Mail Official
triwiyanto123@gmail.com
Editorial Address
Pucang Jajar Timur No. 10, Surabaya, Indonesia
Location
Kota surabaya,
Jawa timur
INDONESIA
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics
ISSN : -     EISSN : 26568624     DOI : https://doi.org/10.35882/ijeeemi
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics (IJEEEMI) publishes peer-reviewed, original research and review articles in an open-access format. Accepted articles span the full extent of the Electronics, Biomedical, and Medical Informatics. IJEEEMI seeks to be the world’s premier open-access outlet for academic research. As such, unlike traditional journals, IJEEEMI does not limit content due to page budgets or thematic significance. Rather, IJEEEMI evaluates the scientific and research methods of each article for validity and accepts articles solely on the basis of the research. Likewise, by not restricting papers to a narrow discipline, IJEEEMI facilitates the discovery of the connections between papers, whether within or between disciplines. The scope of the IJEEEMI, covers: Electronics: Intelligent Systems, Neural Networks, Machine Learning, Fuzzy Systems, Digital Signal Processing, Image Processing, Electromedical: Biomedical Signal Processing and Control, Artificial intelligence in biomedical imaging, Machine learning and Pattern Recognition in a biomedical signal, Medical Diagnostic Instrumentation, Laboratorium Instrumentation, Medical Calibrator Design. Medical Informatics: Intelligent Biomedical Informatics, Computer-aided medical decision support systems using heuristic, Educational computer-based programs pertaining to medical informatics
Articles 5 Documents
Search results for , issue "Vol. 5 No. 2 (2023): May" : 5 Documents clear
Flatness and Alignment Analysis of Conformity Measuring Instrument Design in X-Ray Modality Hermawan, Aska Putri; Pudji, Andjar; Mak’ruf, Muhammad Ridha
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 5 No. 2 (2023): May
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v5i2.168

Abstract

A surface's verticality or horizontalness can be determined as well as its flatness using a waterpass or spirit level. The alignment and flatness of the X-ray tube and bucky table, which determine the perpendicularity of the X-ray beam, is one of the factors for the Conformance Test, according to PERKA BAPETEN No. 2 of 2018. A traditional waterpass is typically used to obtain that conclusion, but the measurement outcome is still subject to human error because there is no set value. To aim for exact alignment, A digital waterpass using the MPU6050 sensor is made, which produces precise X-Ray images, reduces noise in the form of shadow magnification, and investigates the function of the waterpass in the compliance of the X-Ray unit. Arduino is used as the data processor in this investigation. The output is then shown on an LCD and transmitted over Bluetooth to a computer where it is displayed using Delphi before being saved in Excel. With the deviation standard value of 10 degrees, we have obtained an error value from this research between 2% and 3%, minimum, which is 0.04 for sensor 1 and 0.25 for sensor 2. Sensors 1 and 2 measure 14 degrees at 0.089 and 0.054, respectively. The MPU6050 sensor can be utilized in this study to determine how flat the X-Ray tube and bucky table are about one another. This study's contribution is anticipated to be more effective tool testing, and the data will be kept on file until the next testing session.
Analyzing the Relationship between Dialysate Flow Rate Stability and Hemodialysis Machine Efficiency Baharsyah, Baharudin Adi; Setioningsih, Endang Dian; Luthfiyah, Sari; Caesarendra, Wahyu
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 5 No. 2 (2023): May
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v5i2.169

Abstract

Chronic kidney disease (CKD) is a condition characterized by impaired kidney function, leading to disruptions in metabolism, fluid balance, and electrolyte regulation. Hemodialysis serves as a supportive therapy for individuals with CKD, prolonging life but unable to fully restore kidney function. Factors influencing urea and creatinine levels in hemodialysis patients include blood flow velocity, dialysis duration, and dialyzer selection. This research aims to establish a standard for calculating the dialysate flow rate, thereby enhancing dialysis efficiency. The study employs a pre-experimental "one group post-test" design, lacking baseline measurements and randomization, although a control group was utilized. The design's weakness lies in the absence of an initial condition assessment, making conclusive results challenging. Measurement comparisons between the module and the instrument yielded a 5.30% difference, while the difference between the hemodialysis machine and standard equipment was 4.02%. Furthermore, six module measurements against three comparison tools showed a 0.17% difference for the hemodialysis machine with standard equipment, and a 0.18% difference for the module with standard equipment, with a 0.23% discrepancy between the two. Further analysis is necessary to understand the clinical significance and implications of these measurement variations on overall dialysis efficacy
Analysis of Temperature Distribution in Blood Banks Through Storage of Measurement Results with IoT Monitoring in the Blood Donation Unit of Indonesian Red Cross Surabaya Wardhana, Farisy Azis Satria; Maghfiroh, Anita Miftahul; Titisari, Dyah; Sumber, Sumber; Abdullayev, Vugar
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 5 No. 2 (2023): May
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v5i2.170

Abstract

Temperature or temperature is an indicator of the degree of heat of an object. Cold chain or cold chain is a supply chain system that considers the temperature level in the process. Cold chain to keep frozen or chilled products in an environment with a certain temperature during production, storage, transportation, processing and sales. This is intended to maintain product quality. The purpose of this study was to determine the temperature distribution in the Blood bank at Blood Transfusion Unit Indonesian Red Cross Surabaya City which was used for storage of blood products. By using the ESP32 system and the DS18B20 temperature sensor which will then be monitored via IoT, it will make it easier for users to monitor. The results of these measurements will be stored in a micro SD card for analysis. The data is processed by Non-Parametric Test resulting in an interpretation that the temperature of each shelf is different due to the difference in the location of the sensor placement. The temperature difference is also influenced by the pattern of use and the process of heat transfer from the bottom to the top of the shelf. This research was considered successful with the result of the highest temperature distribution being 3°C and the lowest being 2°C. The location of these racks can be useful in determining day-to-day monitoring measuring points. This value has met the standard for storage of blood products, which is in the range of 2°C-6°C.
Comparative Analysis of Water and Oil Media on Temperature Stability in PID Control-Based Digital Thermometer Calibrator Sofyan, Mochammad; Syaifudin, Syaifudin; Pudji, Andjar; Utomo, Bedjo; Nugraha, Anggara Trisna
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 5 No. 2 (2023): May
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v5i2.171

Abstract

Digital thermometers are measuring instruments needed to perform temperature measurement actions and must be calibrated periodically according to standard measurement methods. The purpose of developing this tool is to add PID control to the calibration media where PID control aims to regulate the stability of the temperature setting to be achieved. This is achieved by studying and evaluating the effect of temperature stability on the heater and LM35DZ temperature sensor. This research method uses the Arduino Nanosystem for data processing and PID system control. The LM35DZ temperature sensor on the heater is regulated by a 2 Channel SSR module using a PID system then the temperature generated by the heater will be read by the LM35DZ and displayed on the LCD. The results of this study, digital thermometer calibrator measurements have been successfully carried out by comparing 3 digital thermometers with different brands, namely Omron 343F, Omron 245, and ThermoOne. The difference in error values in oil media is 3-4% and in water media 2-4% with the value of time stability in water media for 3-3.3 minutes and in oil media for 1-2 hours. With this comparison of calibration media, it is hoped that it can help in measuring temperature with better and more effective results. find methods, results, conclusions.
Experimental Measurement and Analysis: Collimation and Illumination for Conformity Measuring Instrument Design in X-ray Modality Fajar, Fathul; Mak’ruf, Muhammad Ridha; Pudji, Andjar; Rizal, Achmad
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 5 No. 2 (2023): May
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v5i2.172

Abstract

Manual illumination and collimation testing can be affected by subjectivity. Human interpretation and judgment in measuring and adjusting illumination and collimation can vary between individuals, potentially resulting in inconsistent results. The aim of this research is to develop the simplest method for measuring illumination at four points simultaneously and directly storing the measurement data. This objective aims to address the subjectivity issues and improve the reliability and consistency of the testing process, which measures illumination at four points simultaneously and stores the measurement data directly. The method of this study was an experimental measurement and analysis that involved capturing illumination and collimation data using a suitable measuring instrument in an X-ray environment. The collected data is then analyzed to evaluate the suitability of the instrument to the established compliance standards. The module is designed using HC-SR04 sensor as a distance meter and TSL2561 sensor as a light meter. This module is designed using HC-SR04 sensor as a distance meter and TSL2561 sensor as a light meter. In this research, the module has been tested and compared with the results of the comparison tool (Digital Light Meter) and obtained an error value of 1.55% with a module efficiency of 98.45% in the illumination test, and an error of 1.8% with a module efficiency of 98.2% in the collimator test. From this research, it can be concluded that the TSL2561 light sensor can be used to measure the illumination area of the collimator lamp. The contribution of this research is expected to be as follows consistent results from tool testing, provides accuracy of results, is more efficient in cost and energy, and the data will be stored until the next testing time.

Page 1 of 1 | Total Record : 5