cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota adm. jakarta selatan,
Dki jakarta
INDONESIA
Prima Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir
ISSN : -     EISSN : -     DOI : -
Core Subject : Science,
Jurnal Prima Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir, Jurnal ilmiah diterbitkan oleh Pusat Rekayasa Perangkat Nuklir - BATAN Alamat Rekaksi: Pusat Rekayasa Perangkat Nuklir (PRPN) - BATAN
Arjuna Subject : -
Articles 228 Documents
DESAIN KONSEP SISTEM INSTRUMENTASI DAN KENDALI IRADIATOR GAMMA SERBA GUNA 2 X 250 kCi Dian Fitri Atmoko; Sutomo Budihardjo; Ikhsan Shobari
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 6, No 12 (2009): Nopember 2009
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (406.249 KB)

Abstract

ABSTRAK DESAIN KONSEP SISTEM INSTRUMENTASI DAN KENDALI IRADIATOR GAMMA SERBA GUNA 2 X 250 kCi. Telah dilakukan desain konsep sistem instrumentasi dan kendali (SIK) iradiator gamma serba guna 2 x 250 kCi. Permasalahan utama SIK terdapat pada cara mendapatkan dosis serap yang sama dan mekanisme start-up/shut-down dengan faktor keselamatan tinggi. Dari hasil desain konsep, SIK terbagi atas tiga bagian yaitu safety, operasi dan security. Ketiga bagian tersebut digunakan sebagai parameter start-up dan shut-down pada instalasi iradiator yang terkoneksi secara interlock untuk menjamin keselamatan. Keseragaman dosis diperoleh melalui pengaturan waktu penyinaran dengan cara  menghentikan gerakan cerrier  pada  titik  tertentu  dan  selama  selang  waktu  tertentu,  dengan  kecepatan  motor penggerak carrier dibuat konstan. Kata kunci : interlock, instrumentasi, kendali  ABSTRACT CONCEPTUAL DESIGN OF MULTY PURPOSE GAMMA IRRADIATOR 2 X 250 kCi INSTRUMENTATION AND CONTROLL SYSTEM. It has been made a conceptual designed of multi purpose 2 x 250 kCi gamma irradiator instrumentation and controll system (ICS). The problem in  ICS  of  the  irradiator is  how to  get the same dose rate and start-up/shut down mechanism with highest safety factor. The conceptual designed of ICS has  tree  parameters such as safety, operation and security. The tree of parameters used to start-up and shut-down in irradiator installation with interlock system connection to guaranted of safety. The equality of dose rate is obtained by controlling the exposured time with stopped of carrier conveyor in point of stopped carrier and for delay time, with   the constant speed of prime mover carrier the equality. Key word : interlock, instrumentation, control
Pembuatan Detektor Neutron Termal Gas lsian 8F3 Gunarwan Prayitno
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 3, No 5 (2006): Juni 2006
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2468.02 KB)

Abstract

Abstrak Detektor   proporsional   neutron   termal  dengan   tekanan  gas  isian  BF3   54  cmHg  telah   dibuat dilaboratorium  instrumentasi  dan Elektronika reaktor Atom  Yogyakarla (BATAN).  Sebagai katoda terbuat dari bahan aluminium dan anoda dari bahan kawat tungsten, masing-masing berdiameter 3 cm dan 0,3 mm. Pendeteksian neutron termal  melalui  reaksi  sekunder yaitu  reaksi  neutron dengan  inti  atom Boron akan  menghasilkan partikel α partikel   ini  .kemudian  akan  mengionisasi gas  BF3.. Dengan adanya medan listrik yang sangat tinggi antara katoda dan anoda, maka pasangan ion yang terbentuk akan terlarik menuju elektroda yang bersesuaian.. Penumpukan  pasangan ion pada elektroda  akan menghasilkan pulsa keluaran detektor yang sebanding dengan energi neutron yang dating.. Dari pengujian karakteristik detektor neutron didapalkan efisiensi detektor sebesar 15, 54 %, dengan cacahan 6,41 x 1010  panjang Plateau 120 volt, dengan tegangan operasi terbaik 1285 volt.. Abstract A  thermal  neutron proportional  detector containing  BF-3 gas  with pressure  of 54 cm Hg has been made in the electronics and instrumentation   laboratory at Yogyakarta nuclear research center (BATAN). The cathode and anode of the detector are made of aluminum and tungsten with 3 cm and 0,3  mm of diameter respectively.   The thermal neutron detection  is made through secondary reactions  of neutron with boron nucleus that produce alpha particle for ionization  of BF-3 gas.   The high electric field between  the cathode and the anode will attract  those pairs of ions to their  respective  electrodes.   The collected  ion pairs  at  the  cathode  will produce  output pulse  detector  which  is equivalent  to the in coming neutron energy.  The neutron detector characteristics test shows that  the detector efficiency is I 5..54  %.  which counts 6.41 x  1010.   Plateau  length to I 20 volt, with optimal voltage operational is 1285 volt.
ANALISIS TEGANGAN STATIK PADA GRID PLATE REAKTOR TRIGA PELAT Petrus Zacharias; Putut Hery Setiawan; Muhammad Ganjar Putra
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 16, No 1 (2019): Juni 2019
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (428.633 KB)

Abstract

Bahan bakar reaktor riset Bandung akan diubah dari bentuk pelet uranium zirconium hydrideTriga Mark II ke tipe pelat U3Si2-Al seperti yang digunakan pada RSG-GAS. Karena geometri dan dimensi bundel bahan bakar pelat berbeda dengan Triga Mark II, maka grid plate harus didesain ulang, tapi harus sesuai dengan kondisi eksisting teras reaktor. Dari hasil desain ini dilakukan analisis tegangan akibat beban statik yang diterima grid plate dengan menggunakan prosedur analisis circular perforated area Article A-8000 ASME Section III 2004. Untuk menggunakan metode ini, grid plate diasumsikan sebagai circular perforated flat plate, kemudian dianalisis dengan menggunakan konsep equivalent solid plate. Konsep ini memodifikasi nilai konstanta elastik bahan untuk menggantikan konstanta elastik bahan grid plate. Dengan konstanta baru ini, analisis tegangan dilakukan berdasarkan konsep teori klasik pelat. Hasil analisis menunjukkan bahwa tegangan maksimum yang terjadi pada grid plate sebesar 48,123 KPa, nilai ini jauh lebih rendah dari nilai tegangan yang diijinkan yaitu 165,5 MPa. Demikian juga dengan defleksi maksimum yang terjadi yaitu 0,0004 mm, nilai ini juga lebih kecil dari nilai defleksi yang diijinkan yaitu 0,00585 mm. Dengan demikian desain grid plate ini memenuhi syarat aman. Kata kunci : Grid plate, circular perforated flat plate, tegangan maksimum, defleksi maksimum.
PENGUKURAN KINERJA BIAYA DAN WAKTU PROYEK UNTUK MENCAPAI SASARAN MUTU PRPN Harno Garnito; Ari Satmoko
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 9, No 2 (2012): Nopember 2012
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (341.13 KB)

Abstract

A MEASUREMENT OF PROJECT COST AND SCHEDULE PERFORMANCE TO ACHIEVE PRPN’S QUALITY OBJECTIVES (Case Study on Improvement and Function Test of Medium Dose Brachytherapy Cervical Cancer Devices). Establishment of PRPN’s quality objectives requiring to know the success rate of projects being implemented. Earned Value method provides information on the position of project progress and to estimate the progress of the next period, in terms of cost and completion schedule. In the case of Improvement and Function Test of Medium Dose Brachytherapy Cervical Cancer Devices, at 3th months showed good cost performance (CV > 0), there is no cost variance, and be estimated 32.46% of budget or 73.297.273 IDR cost savings up to the end of project. Good schedule performance (SV > 0), there is no schedule variance, and the project will be completed by 2 months ahead of schedule.PENGUKURAN KINERJA BIAYA DAN WAKTU PROYEK UNTUK MENCAPAI SASARAN MUTU PRPN (Studi Kasus pada Program Penyempurnaan dan Uji Fungsi Perangkat Brakiterapi Dosis Sedang Kanker Servik). Ditetapkannya sasaran mutu PRPN menuntut untuk dapat diketahui tingkat keberhasilan proyek yang sedang dilaksanakan. Metode Earned Value memberikan informasi mengenai posisi kemajuan proyek serta dapat memperkirakan kemajuan pada periode selanjutnya, dalam hal biaya dan waktu penyelesaian. Pada kasus Program Penyempurnaan dan Uji Fungsi Perangkat Brakiterapi Dosis Sedang Kanker Servik, pada bulan ke-3 menunjukkan kinerja biaya yang baik (CV > 0), tidak ada penyimpangan biaya, sampai dengan akhir kegiatan diperkirakan ada penghematan sebesar 32,46% dari Rincian Anggaran Biaya semula, atau sebesar Rp. 73.297.273,-. Kinerja waktu juga baik (SV > 0), tidak ada penyimpangan jadual, dan diperkirakan proyek akan diselesaikan dengan waktu 2 bulan lebih cepat dari rencana.
PERANCANGAN KONTAINER ISOTOP Ir-192 10 Ci DARI BAHAN TUNGSTEN SERBUK UNTUK BRAKITERAPI Tri Harjanto; Kristiyanti Kristiyanti; Maradu Sibarani
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 10, No 2 (2013): November 2013
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2946.943 KB)

Abstract

ABSTRAK PERANCANGAN  KONTAINER  ISOTOP   Ir-192   10  Ci  DARI  BAHAN  TUNGSTEN SERBUK  UNTUK BRAKITERAPI.  Telah  dilakukan  perancangan kontainer dari bahan tungsten serbuk untuk  transportasi isotop   Ir-192  dengan aktivitas  10  Ci  yang   akan   digunakan untuk brakiterapi. Bahan  tungsten  memungkinkan untuk  dipergunakan dalam   pembuatan kontainer yang  aman dan  handal dengan volume dan  berat  lebih kecil dibandingkan menggunakan bahan timbal. Permasalahan yang  timbul adalah  pembentukan logam  tungsten yang mempunyai suhu leleh    3422  °C,  sulit  dilakukan dengan teknologi sederhana.  Solusinya digunakan   teknologi serbuk di mana serbuk tungsten dibentuk  dengan proses pemadatan dingin  di  dalam  casing besi  yang  mampu menahan tekanan sampai   mencapai 800  MPa.  Lingkup  perancangan ini meliputi penentuan tebal  dinding kontainer, bentuk  dan  dimensi  umum  kontainer untuk  wadah sumber Ir-192.  Sumber  Ir-192  disimpan dalam   kapsul dengan  ukuran   diameter 1  mm  dan panjang 5 mm. Kapsul  tersebut dirangkai dengan seling  berdiameter 0,9 mm dan  panjang 1500 mm.  Berdasarkan  perhitungan diperoleh bahwa untuk  sumber Ir-192  dengan aktivitas  10  Ci, tebal  dinding  yang   diperlukan adalah  62  mm.  Casing disesuaikan dengan  standar  pipa  5” schedule 40  dengan diameter dalam  126,6  mm.  Dengan teknologi  ini maka  tungsten serbuk yang   dibutuhkan   sebesar    32,516 kg.  Perhitungan teoritis  serapan  radiasinya   memenuhi ketentuan dari  BAPETEN  yaitu  paparan radiasi  sebesar 0,05  mRem/jam pada jarak  1 m dari permukaaan kontainer. Kata kunci : Isotop  Ir-192, kontainer, tungsten, serbuk, tebal ABSTRACT THE DESIGN OF 10 Ci Ir-192  ISOTOPE CONTAINER  IN TUNGSTEN  POWDER  FOR BRACHYTHERAPY. The container in tungsten powder  to transport Ir-192 isotope with activity of 10 Ci for brachytherapy has been designed. Tungsten material  can  be  formed  into a safe  and reliable container reducing volume  and  weight compared to the lead  materials. The problem  that arises is  the  establishment of tungsten metal  which  has melting  temperature of 3422  ° C  is difficult to be processed using  simple  technology. The solution  is to use  the powder  technology. Tungsten  powder   is  formed   using   cold  compaction process  in  the  iron  casing  capable  to withstand a pressure at 800 MPa.  The scope of this design is to determine wall thickness, shape and  its general dimensions of the containers for Ir-192 source. The source is wrapped in capsule with a diameter of 1  mm  and a length  of 5  mm.  The  capsule is  combined with wire  having diameter of 0,9  mm and   length  of 1500  mm. Calculation showed that  container for Ir-192 with activity of 10 Ci required a wall  thickness of 62 mm.  The  case uses the  standard pipe  5" with schedule 40 having  inside diameter of 126,6  mm. This technology needs 32,516 kg of tungsten material.  The   theoritical  calculation  of  the   radiation   absorption meets  well  the   BAPETEN requirement which  states 0.05  mrem/hr of radiation  exposure at  the  distance of 1 m from the container surface. Kata kunci : Isotope Ir-192, container, tungsten, powder, thickness
TINJAUAN PRA OPERASIONAL PEMBANGUNAN GEDUNG NTC DENGAN ALTERNATIF LOKASI YOGYAKARTA Hasriyasti Saptowati Saptowati
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 7, No 13 (2010): Juni 2010
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (853.141 KB)

Abstract

TlNJAUAN PRA OPERASIONAL PEMBANGUNAN GEDUNG NTC DENGAN ALTERNATIF LOKASI YOGYAKARTA. Gedung NTC (Nuclear Training Centre) direncanakan akan dibangun dilokasi PTAPB (Pusat Teknologi Akselerator dan Proses Bahan) diperlukan sebagai wadah bagi pendidikan dan pelatihan untuk menjadikan profesional muda yang kompeten dalam mengoperasikan PL TN. Sebelum pembangunan dilaksanakan kita perlu meninjau kelayakan lokasi sebagai sarana dan salah satu persyaratan dari pra operasional pembangunan gedung. Dengan tinjauan ini diharapkan kita dapat meminimalis biaya baik yang akan direncanakan maupun biaya tak terduga. Tinjauan pra operasional ini berdasarkan peraturan pemerintah PP no: 4711997. PRE OPERA TlONAL REVIEW OF DEVELOPMENT BUILDING WITH AL TERNA TIVE LOCA TlONS YOGYAKARTA NTC. NTC Building (Nuclear Training Centre) which is planned to be built in site of PTAPB (Center for Materials and Process Technology Accelerator) is required as a forum for education and training to make young professionals who are competent in operating nuclear power plants. Prior to the construction carried out we need to review the feasibility of a location as one of the facilities and operational requirements of the pre construction of the building. With this review we can expect to minimize both the cost of planned or unexpected costs. This pre-operational review is based on the government regulation no: 4711997.
PERHITUNGAN SEBARAN OZON DARI CEROBONG IRADIATOR GAMMA PRFN Rissa Damayanti; Iwan Roswandi; Petrus Zacharias
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 12, No 2 (2015): November 2015
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2068.386 KB)

Abstract

ABSTRAKPERHITUNGAN SEBARAN OZON DARI CEROBONG IRADIATOR GAMMA PRFN, Analisis perhitungan meliputi estimasi seberapa banyak ozon yang tersebar di area sekitar instalasi iradiator gamma PRFN yang dihasilkan selama proses iradiasi berlangsung. Ozon yang terbentuk selama proses iradiasi akan disirkulasi oleh blower ozon dan dibuang ke udara bebas lewat cerobong buangan dengan sistem pertukaran udara ruangan iradiasi tipe basah yang membutuhkan minimal 20 kali pergantian udara per jam atau konsentrasi ozon di udara tidak melebihi nilai batas yang diizinkan yaitu 0,1 ppm. Pergerakan ozon di atmosfer / udara bebas terjadi dalam tiga dimensi secara horizontal maupun transversal, sesuai dengan arah angin (adveksi) maupun vertikal, ke lapisan atas atmosfer bumi. Untuk melakukan perhitungan tersebut dilakukan dengan menggunakan Model Dispersi Gauss. Data yang digunakan dalam melakukan pehitungan adalah kecepatan angin minimal pada ketinggian cerobong 11 meter sebesar 0.1 m/detik dan kecepatan angin maksimal sebesar 6 m/detik pada saat pagi, siang dan malam hari. Laju emisi ozon (Q) adalah 0.000707 gram/detik, dengan variasi jarak pemaparan menurut arah angin dari 1 meter hingga 6 meter (0.001 – 0.00 Km). Dari hasil perhitungan yang telah dilakukan diperoleh kondisi paparan ozon tertinggi, yaitu : pada kecepatan angin 0.1 m/s, kestabilan udara kelas A (sangat tidak stabil) pada pagi/siang dengan intensitas matahari kuat. Pada nilai-nilai paparan ozon tersebut pada jarak x ≤ 1 m, y = 0, z = 1,1.5,2,2.5,3,…17 m nilai konsentrasi paparan ozon > 0,1 ppm (lebih dari nilai batas yang diizinkan), namun kondisi pada lokasi dengan koordinat lain x ≥ 1 m, y = 0, z = 1,1.5,2,2.5,3,…17 m, dan x = 1,2,3,4,5,6 m, y 0.5,1,1.5,2,2.5,3 m, z = 0 nilai konsentrasi paparan ozon < 0,1 ppm (tidak lebih dari nilai batas yang diizinkan). Sehingga dapat dikatakan yang mempengaruhi besar dari konsentrasi paparan ozon ke lingkungan antara lain: kecepatan angin, kecepatan emisi gas buang, kecepatan linear gas buang dalam cerobong, percepatan gravitasi, kelas kestabilan udara, serta selisih antara temperatur gas buang dan temperatur udara lingkungan.Kata kunci: Iradiator Gamma, Sebaran Ozon, Cerobong Iradiator, Dispersi. ABSTRACTA CALCULATION OF OZONE DISTRIBUTION FROM THE CHIMNEY GAMMA IRRADIATOR PLANT OF PRFN. Calculation includes estimation of ozone scattered in the area around the installation of the PRFN gamma irradiator generated during irradiation process. Ozone which is formed during irradiator in operation will be circulated by the blower and discharged into the atmosphere through the exhaust chimney of the wet type air exchange system irradiation room that requires a minimum of 20 times the air changes per hour or the concentration of ozone in the air does not exceed the allowed limit is 0.1 ppm. The movement of ozone in the atmosphere occurs in three dimensions horizontally and transverse, in accordance with the direction of the wind (advection) or vertically, to the top layer of the earth's atmosphere. To perform these calculations the Gaussian Dispersion Model has been used. The data used in the calculation are the minimum wind speed at the height of the chimney 11 meters of 0.1 m / sec and a maximum wind speed of 6 m / sec during the morning, afternoon and evening. Ozone emission rate (Q) is 0.000707 grams / sec, with a variation of exposure downwind distance of 1 meter to 6 meters (0.001 - 00:00 Km). From the results of the calculations have been done obtained the highest ozone exposure conditions, ie: at a wind speed of 0.1 m / s, air stability classes A (very unstable) in the morning / afternoon with strong solar intensity. At the values of ozone exposure are at a distance x ≤ 1 m, y = 0, z = 1,1.5,2,2.5,3, ... 17 m value exposure to ozone concentrations> 0.1 ppm (over limit values allowed) , but the conditions at other locations with coordinates x ≥ 1 m, y = 0, z = 1,1.5,2,2.5,3, ... 17 m, and x = 1,2,3,4,5,6 m, y 0.5,1,1.5,2,2.5,3 m, z = 0 value exposure to ozone concentrations <0.1 ppm (no more than the permitted limit values). So it can be said that influence of the concentration of ozone exposure to the environment, among others: the wind speed, the speed of exhaust emissions, exhaust gas linear velocity in the chimney, the acceleration of gravity, air stability classes, as well as the difference between the temperature of the exhaust gas and ambient air temperature.Keywords : Gamma Irradiator, Distribution of Ozone, Chimney Irradiator, Dispersion
UJI KIT RADIOIMMUNOASSAY (RIA) DENGAN MENGGUNAKAN PERANGKAT RIA MEDIA SAMPEL MANUAL Riswal Siregar
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 5, No 9 (2008): Juni 2008
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2348.281 KB)

Abstract

ABSTRAK Telah dilakukan pengujian  Kit RIA dengan menggunakan perangkat  RIA media sampel manual. Pada uji kit ini assay yang  digunakan  untuk menentukan  kadar  T4 ( thyroxine  ) dalam suatu sampel berupa plasma  darah seorang pasien.  Untuk mendapatkan  hasil yang cepat dan tepat, penanganan  dan pengolahan  hasil pendeteksian  ini digunakan  perangkat  RIA media  manual dengan  antarmuka  devasys  USB  yang  telah  menerima  data  digital  parallel.  Data  ini  telah dikonversi  oleh  modul  elektronik  perangkat  RIA dari bentuk  sinyal  keluaran  dari  hasil reaksi menjadi berupa sederetan pulsa serial. Kit RIA ini baik dan stabil karena telah memenuhi syarat maksimum binding (%BIT) dan non spesifik binding ( % NSB) Kata Kunci:  kit RIA,  perangkat  RIA  ABSTRACT It Has been tested  a RIA   Kit by using RIA  peripheral from manual sample media.  The  test of this RIA kit uses assay  to determine the rate of T4 (thyroxine)  in a sample in the form of blood plasma of a patient.  To get    very quickly result and precisely,  the handling  and processing  of this detection usus RIA result,  peripheral of manual media with interface of devasys USB which accepts  paralel  digital  data.   This  data  have  been  converted  by  electronic   module  of  RIA peripheral  from its output signal shape  which  is the  result of a reaction   into sequence     of serial format. It has been  concluded  that    This RIA kit is stable  and good  because  it has achieved  the  standard maximum binding ( % B It)  and non  specific  binding ( % NSB ).Keyword:  RIA kit,  RIA of peripheral
PERANCANGAN KAIT (HOOK) DENGAN KAPASITAS ANGKAT 10 TON Syamsurijal Ramdja
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 3, No 6 (2006): November 2006
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2690.823 KB)

Abstract

ABSTRAK                                     .                                                                                                                                               PERANCANGAN KAIT (HOOK)  DENGAN  KAPASITAS ANGKAT 10 TON.  Telah  dilakukan perancangan kait dengan kapasitas angkat 10 ton yang digunakan pada  Kren (Crane).  Perancangan berdasarkan standar yang berlaku dan dengan faktor keamanan yang konservatif. Pemeriksaan kekuatan bahan dilakukan pada penampang yang paling kritis yaitu tegangan tarik pada penampang yang  terkecil. Bantalan yang  digunakan adalah jenis  bantalan peluru  aksial. Pemilihan dan perhitungan juga dilakukan untuk gantungan kait, pemikul kait dan mur serta  sackel. Kata kunci :  kait, penampang kritis, kekuatan bahan
PEMBUATAN KARET BORON UNTUK PROTEKSI RADIASI NEUTRON Sri Mulyono Atmojo; Tri Harjanto
PRIMA - Aplikasi dan Rekayasa dalam Bidang Iptek Nuklir Vol 1, No 2 (1999): Oktober 1999
Publisher : BATAN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1775.226 KB)

Abstract

ABSTRAKPEMBUATAN KARET BORON  UNTUK PROTEKSI  RAD/AS/  NEUTRON.  Suatu laboratorium  neutron radiografi diperlukan shielding elastis yang terbuat dari karet boron. Untuk maksud tersebut. dilakukan penelitian pembuatan karet boron dari karet alam  fase padat dengan serbuk senyawa boron H2B03 dan Na2B407.  Komposisinya adalah 40 pphr (part per one hundred rubber) H2B03.  serta 50 pphr dan 100 pphr Na2B407. Metoda pembuatan sampel mengikuti proses pengolahan karet secara klasik..  Hasil pengujian daya serap terhadap neutron termal untuk masing-masing sampel adalah 94. 95 % untuk karet boron dari H2BO33.   80.77 % untuk karet boron Na2B407  Hasil ini cukup baik namun sifat fisik masih perlu perbaikan. ABSTRACTBORON RUBBER AS A NEUTRON RADIATION PROTECTION MANUFACTURE. The neutron radiography laboratory. need an elastic shield.  which is made from a boron rubber.. To solve this problem. the experiment of boron rubber manufacture was investigated..Boron rubber is made of the natural rubber solid phase and some of boron compounds. They have some composition as follow.·  40 pphr H2BO3.    50 pphr and 100 pphr Na2B407. The classical methode is used in the rubber processing.. By this experiment show that the absorption strength of H2BO3.  natural  rubber  is  94. 95  %.   the  Na2B407.,   natural  rubber absorption strength are 80. 77  % and 84.95  %.   This results are very good.  but their physics properties should have to development

Page 2 of 23 | Total Record : 228