cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
,
INDONESIA
Journal of Medical Physics and Biophysics
ISSN : 23552727     EISSN : 23552719     DOI : -
Core Subject : Health, Science,
Journal of Medical Physics and Biophysics is a gold open-access journal and serves as official publication media of the Indonesian Association of Physicists in Medicine, IAPM (Aliansi Fisikawan Medik Indonesia, AFISMI). JMPB publishes articles with the general concern on the application of physics in medicine and the biological system. The role of physics highlighted in the journal can be of theoretical, experimental, or clinical nature. Review and original articles in radiation oncology, diagnostic and interventional radiology, nuclear medicine, biomaterial, physical biology, physical modeling of biological system, and other related sciences are welcome. Any opinions stated on the articles published in JMPB are those of the author(s) and do not necessarily reflect the policy of IAPM/AFISMI unless otherwise stated.
Arjuna Subject : -
Articles 9 Documents
Search results for , issue "Vol 5, No 1 (2018)" : 9 Documents clear
Associate Medical Physicists: our bridge towards fulfilling national demand of Clinically Qualified Medical Physicists Supriyanto Ardjo Pawiro
Journal of Medical Physics and Biophysics Vol 5, No 1 (2018)
Publisher : Indonesian Association of Physicists in Medicine (AIPM/AFISMI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (267.9 KB)

Abstract

Virtual study to investigate the detectability of breast abnormalities on 2D mammography and digital breast tomosynthesis Kristina Tri Wigati; Hannah Manssens; Liesbeth Vancoillie; Cockmartin Lesley; Djarwani Soeharso Soejoko; Hilde Bosmans; Kristina Bliznakova
Journal of Medical Physics and Biophysics Vol 5, No 1 (2018)
Publisher : Indonesian Association of Physicists in Medicine (AIPM/AFISMI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1576.455 KB)

Abstract

This paper describes the use of virtual clinical trial software, as developed and improved in the frame of the Horizon2020 MaXIMA project, to study particular aspects of 2D mammography and digital breast tomosynthesis. A voxel-based breast phantom with inserted mathematical models of an irregular mass and two microcalcifications was created. Image acquisition was simulated by using XRAYImagingSimulator, while image reconstruction was accomplished with FDKR software. Series of images were created for different angular ranges with an identical total dose. Detectability of the abnormalities was investigated using visual assessment and quantitative measurements. The results agree with other studies in literature studying the same aspects and therefore confirm the value of the new framework for other future applications.
The lateral shift effect of gamma index evaluation on tomotherapy Yosi Sudarsi Asril; Nuruddin Nasution; Wahyu Edy Wibowo; Supriyanto Ardjo Pawiro
Journal of Medical Physics and Biophysics Vol 5, No 1 (2018)
Publisher : Indonesian Association of Physicists in Medicine (AIPM/AFISMI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (592.99 KB)

Abstract

Fourteen patients with different cases have been planned and treated using helical Tomotherapy HI-ART system. To investigate the lateral shift effect on gamma index, the planning verification was evaluated for a point dose and a fluence dose measurement using ion chamber and Gafchromic EBT3 film, respectively. As a result, the difference between a measured and calculated point dose was under 3% for all interest organs, which account for 1.46±0.71% (parotid), 1.97±0.56% (pelvis and abdomen), 2.27±0.24% (brain), 1.56±0.51% (nasopharynx), and 1.43±1.3% (breast). In addition, Gamma index criteria used to evaluate fluence dose was 3mm (distance-to-agreement) and 3% (dose-difference) with 90% passed rate. Overall, the results, found in this study, shows that a lateral shift of the patient table resulted in an error beyond an acceptable tolerance if the table was shifted at more than 3mm. Gamma index criteria, then, is met if the lateral shift was within 3mm.
Kuantisasi dan analisis citra computed radiography pada pemeriksaan sinus paranasal pasien pediatrik dengan metode line profile Sari Yuliani; Lukmanda Evan Lubis; Nurlely Nurlely; Djarwani Soeharso Soejoko
Journal of Medical Physics and Biophysics Vol 5, No 1 (2018)
Publisher : Indonesian Association of Physicists in Medicine (AIPM/AFISMI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1009.67 KB)

Abstract

Pada penelitian ini dilakukan pengujian dari metode line profile, suatu metode kuantisasi citra CR yang memiliki potensi penggunaan sebagai alat bantu bagi ahli radiologi dalam interpretasi citra radiologi. Metode line profile memberikan pertimbangan referensi kuantitatif tambahan dengan obyektivitas tinggi, serta mendeteksi abnormalitas yang mungkin tidak terlihat secara visual. Sampel berupa citra CR dari 45 pasien pediatrik dengan rentang usia 1-5 tahun, 5-10 tahun, dan 10-15 tahun dibagi berdasarkan anatomi yang dijadikan objek kuantisasi yaitu konka nasalis inferior, sinus maksilla, sinus frontal, sinus sphenoid, dan sinus ethmoid, dan dianalisa menggunakan metode line profile. Garis uji (line profile) dibuat dengan posisi dan ukuran tetap terhadap acuan berupa tulang (bony landmark) dengan menggunakan perangkat lunak ImageJ. dan kuantitatif; yakni membandingkan line profile pasien terdiagnosa abnormal dengan baseline dari line profile pasien terdiagnosa normal. Hasil penelitian menunjukkan bahwa secara kualitatif metode ini menunjukkan efektivitas untuk anatomi objek konka nasalis inferior, sinus maksilla, dan sinus frontal dengan kecocokan antara kuantisasi dan hasil diagnosa radiolog sebesar 82%, 81%, dan 100% berturut-turut.  Sedangkan secara kuantitatif metode ini efektif untuk objek sinus maksilla dan sinus frontal dengan tingkat kecocokan 89% pada sinus maksilla dan 50% pada sinus frontal.
Point dose measurement on center and peripheral target for stereotactic treatment using Helical Tomotherapy Hi-Art Laras Ati Nur Fatimah; Nuruddin Nasution; Wahyu Edy Wibowo; Supriyanto Ardjo Pawiro
Journal of Medical Physics and Biophysics Vol 5, No 1 (2018)
Publisher : Indonesian Association of Physicists in Medicine (AIPM/AFISMI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (530.313 KB)

Abstract

Stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) using tomotherapy were advanced radiotherapy technique with prescribing high dose on the peripheral target to get as steep as possible fall-off dose criteria on the target. These technique need an accurate and high precision treatment delivery also passing the criteria for patient specific quality assurance. Point dose measurement was a simple verification to ensure these goals. However, there are many issues for point dose measurement with ionisation chamber related to the problem of high dose gradient area on the peripheral target. Therefore, the purpose of this study was to verify the assessment criteria of ±3% discrepancies for center and peripheral target measurement. The work has been done by point dose verification for 11 patient with brain cancer using Helical Tomotherapy Hi-Art. Point dose measurement were done on the center and peripheral PTV, also brainstem for organ parameter in the off-axis area, using Exradin A1SL. The measurement results show that highest discrepancy compared to the dose plan for center and peripheral target reach 1.95% and 2.81%, respectively. The Higher discrepancies shows for peripheral target compared to the center target measurement. The measurement on the brainstem show a highest discrepancies reach 5.29%. This result occur because of the off-axis area of the brainstem location. In conclusion, the center and peripheral target measurement are meet the criteria ±3% by the dose plan with peripheral target measurement shows higher discrepancies influences by volume averaging effect and lack of particle equilibrium of the condition related to the chamber size.
Metode line profile: pendekatan terhadap evaluasi kuantitatif citra Computed Radiography thoraks pada pasien pediatrik Halimah Harfah; Lukmanda Evan Lubis; Kristina Tri Wigati; Djarwani Soeharso Soejoko
Journal of Medical Physics and Biophysics Vol 5, No 1 (2018)
Publisher : Indonesian Association of Physicists in Medicine (AIPM/AFISMI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1887.327 KB)

Abstract

Tujuan dari penelitian ini adalah untuk menunjukkan fisibilitas metode line profile sebagai metode evaluasi kuantitatif citra computed radography thoraks pasien pediatrik. Sampel berupa 36 citra thoraks pediatrik yang terdiri dari 26 citra thoraks normal dan 10 citra thoraks abnormal, diperoleh dengan menggunakan sistem CR. Line profile dibuat dengan menggunakan perangkat lunak imageJ dan dikuantisasi menggunakan fortran 90. Setiap line profile diberi enam perlakuan (metode) yang berbeda, yakni tanpa modifikasi nilai piksel (metode I), modifikasi nilai piksel menjadi kontras region of interest (ROI) tulang (metode II), modifikasi nilai piksel menjadi kontras ROI thoraks (metode III), normalisasi rentang nilai piksel (metode IV), normalisasi rentang nilai piksel dan modifikasi kontras ROI tulang (metode V), serta normalisasi rentang nilai piksel dan modifikasi kontras ROI thoraks (metode VI). Verifikasi metode dilakukan dengan menggunakan coefficient of variation (CoV). Metode terbaik dipilih dan digunakan sebagai acuan line profile normal yang akan dibandingkan dengan line profile citra abnormal. Untuk membandingkan secara kuantitatif line profile normal dan abnormal, diskrepansi (δ) digunakan sebagai parameter. Hasil penelitian menunjukkan bahwa metode line profile dengan menggunakan normalisasi rentang nilai piksel adalah metode yang memiliki fisibilitas untuk membedakan citra normal dan abnormal. Dari metode ini, kelainan dengan δ terkecil adalah bronchitis dan δ terbesar adalah effusion. Penelitian lanjutan diperlukan untuk meningkatkan fisibilitas metode ini untuk kasus abnormalitas lain.
Lateral setup error analysis of dosimetric impact for nasopharynx carcinoma using intensity modulated radiotherapy treatment Syarifatul Ulya; Nuruddin Nasution; Wahyu Edy Wibowo; Supriyanto Ardjo Pawiro
Journal of Medical Physics and Biophysics Vol 5, No 1 (2018)
Publisher : Indonesian Association of Physicists in Medicine (AIPM/AFISMI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (596.253 KB)

Abstract

Patients with nasopharyngeal carcinoma have been analyzed for lateral setup error. Systematic and randomized inter-fractional setup errors were evaluated in 48 patients with this case. Based on these errors, the margin was drawn from CTV to obtain the delineation of PTV structure, called PTV margin. MVCT system in tomotherapy has been used to get the number of error with four-degree direction setup. Moreover, the biggest error direction value was evaluated with in 6 patients and analyzed at D98 in each PTV and OARs. The result of PTV margin for the lateral, longitudinal, vertical, and rotation was 4.91 mm, 4.27 mm, 3.37 mm and 3.53 mm, respectively. According to the result of the PTV margin, a lateral direction showed the biggest value of error. So, achievable dose coverage of PTVs on the effect of the lateral shift were 87.04%, 60.19%, and 50% for 2, 4 and 6 mm, respectively. Furthermore, OAR dose in the right position is increasing with larger shift setup direction.
Karakteristik berkas foton lapangan kecil setengah lapangan (half beam) dengan menggunakan wedge Elsa Angelina; Wahyu Edy Wibowo; Riana Dian Pertiwi; Supriyanto Ardjo Pawiro
Journal of Medical Physics and Biophysics Vol 5, No 1 (2018)
Publisher : Indonesian Association of Physicists in Medicine (AIPM/AFISMI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (574.737 KB)

Abstract

Penelitian ini bertujuan untuk mengetahui profil berkas foton lapangan kecil setengah lapangan (half beam) dengan menggunakan wedge yang dapat menjawab tantangan radioterapi tumor sino-nasal yang diketahui memiliki lokasi yang sangat kompleks. Pengukuran dilakukan dengan berkas foton 6MV menggunakan dosimeter film Gafchromic EBT3 yang dilakukan pada kedalaman 1.5 cm, 5 cm dan 10 cm untuk setiap lapangan penyinaran 0.8 × 0.8 cm2, 1.6 × 1.6 cm2, 2.4 × 2.4 cm2, 3.2 × 3.2 cm2 dan 4 × 4 cm2 dengan menggunakan physical wedge dengan besar sudut 15°, 30°, 45° dan 60° serta dilakukan variasi penyinaran yaitu daerah penyinaran wedge tipis dan tebal. Hasil pengukuran didapatkan bahwa nilai FWHM dan penumbra cenderung naik seiring dengan semakin dalamnya pengukuran. Selain itu, nilai FWHM cenderung lebih besar 1.59% saat daerah penyinaran wedge tipis. Penumbra memiliki rentang nilai 0.15 – 0.36 cm dengan anomali sebesar 80% (n=135) jika definisi penumbra merupakan jarak level isodosis 80% - 20% dan 0.24% (n=135) jika definisi penumbra merupakan jarak level isodosis 50% - 20%. Kesimpulannya, dari hasil pengukuran nilai deviasi FWHM dan penumbra (80% - 20%) terkecil masing-masing 0.92% dan 0.33 cm pada lapangan 0.8×0.8 cm2 wedge 60°, namun tidak ada hubungan yang pasti antara wedge dengan nilai FWHM dan penumbra pada lapangan kecil.
Perbandingan profil berkas wedge lapangan kecil foton 6 MV terhadap pengaruh jaw dan MLC sebagai pembentuk lapangan Riana Dian Pertiwi; Wahyu Edy Wibowo; Elsa Angelina; Supriyanto Ardjo Pawiro
Journal of Medical Physics and Biophysics Vol 5, No 1 (2018)
Publisher : Indonesian Association of Physicists in Medicine (AIPM/AFISMI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (397.328 KB)

Abstract

Kanker sinonasal memiliki karakteristik yang unik berkaitan dengan anatomi yang berdekatan dengan OAR, sehingga memerlukan gradien dosis yang tinggi untuk melakukan treatment yang dapat diamati dengan melihat FWHM dan penumbra yang dihasilkan pada profil berkas pada lapangan wedge yang dihasilkan dengan menggunakan jaw dan MLC. Wedge yang digunakan merupakan physical wedge [L1] dengan sudut 15o, 30o, 45o, dan 60o  yang dilakukan di kedalaman 1.5 cm, 5 cm dan 10 cm pada lapangan 1 × 1 cm2, 2 × 2 cm2, 3 × 3 cm2 dan 4 × 4 cm2  dengan menggunakan film Gafchromic EBT3. Hasil menunjukkan nilai penumbra dan FWHM terbesar diperoleh dengan MLC sebagai pembentukan lapangan dan nilai terkecil dengan MLC (edge) sebagai pembentukan lapangan. Perbedaan hasil tersebut dikarenakan adanya perbedaan faktor transmisi jaw dan faktor transmisi MLC, dan adanya pengaruh dari kebocoran interleaf dan transmisi pada bagian tepi dari MLC. Penggunaan wedge pada profil berkas dapat mempengaruhi nilai FWHM dan penumbra yang dihasilkan sebagai akibat adanya efek beam hardening yang muncul dengan penggunaan physical wedge. Hasil studi ini menunjukkan pembentukan lapangan dengan menggunakan MLC (edge) merupakan pembentukan lapangan secara optimal, sedangkan penggunaan wedgedapat mempengaruhi nilai FWHM yang dihasilkan. [L1]Hindari kata berulang 

Page 1 of 1 | Total Record : 9