Abstract

Local wisdom enhances building aesthetics and imparts philosophical values. Bioclimatic architecture has become popular among architects and designers because it reduces energy consumption without harming the environment. A study at the Universitas Diponegoro Campus Mosque applied bioclimatic design using a traditional joglo roof model simulated with Autodesk Ecotect. Measurements showed the maximum suhue on the second floor reached 28°C. Simulations indicated that bioclimatic design could reduce indoor suhues by 4.3°C - 5.2°C to 24.5°C. This result shows a lower suhue difference compared to the existing design by 7.5°C. This design can be a prospective solution for improving thermal comfort and providing an environmentally friendly design.