Dammar, Irfan
Department Of Prosthodontic, Faculty Of Dentistry, Hasanuddin University, Makassar, Indonesia

Published : 23 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 23 Documents
Search

The difference maximum bite force and mastication ability in patients wearing metal framework and acrylic removable partial dentures : Perbedaan kekuatan gigit maksimal dan kemampuan mastikasi pasien pengguna gigi tiruan sebagian lepasan kerangka logam dengan akrilik Hastinawaty; Wahyuni, Nurimah; Habar, Ike Damayanti; Jubhari, Eri Hendra; Dammar, Irfan
Makassar Dental Journal Vol. 14 No. 1 (2025): Volume 14 Issue 1 April 2025
Publisher : Makassar Dental Journal PDGI Makassar

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35856/mdj.v14i1.980

Abstract

Dentures are expected to restore masticatory function, which is an indicator of the functional complex of mastication influenced by elevator muscle activation from craniomandibular biomechanics. The level of bite force is important to determine the effec-tiveness of mastication in denture-using patients. This study evaluated the differences in maximal bite force values and mastica-cation ability in metal and acrylic partial denture patients. Subjects were RPD users; 12 metal frame patients and 12 acrylic pa-tients. The bite force values the patients were measured using a byte gauge. Mastication ability was assessed using a mastica-cation ability questionnaire. The age groups of 46-55 years and 56-65 years used the RPD the most. The mean maximal bite force of metal-frame RPD patients was 260.92 N and 90.67 N in acrylic. All of the metal frame users had good mastication ability and only 5% of acrylic RPD users had good ability. Only 66.7% of metal frame RPD patients had a high quality of life and 8.3% of acrylic. It was concluded that the maximal bite force value of metal frame RPD patients was greater than acrylic.
Improving the nutritional quality of patients with edentulous totalis accompanied by severe lingir resorption using complete dentures: Meningkatkan kualitas gizi penderita edentulus totalis disertai resorbsi parah lingir menggunakan gigi tiruan lengkap Tresnawati, Indah; Jubhari, Eri Hendra; Dammar, Irfan
Makassar Dental Journal Vol. 14 No. 2 (2025): Volume 14 Issue 2 August 2025
Publisher : Makassar Dental Journal PDGI Makassar

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35856/mdj.v14i2.983

Abstract

Severe alveolar bone resorption is a challenge in the fabrication of complete dentures. Loss of all teeth often leads to impaired masticatory function, which can affect the digestive system and nutritional intake. The close mouth moulding technique is sug-gested to overcome the limitations of conventional techniques in flat ridge cases, in order to obtain a denture that is firm and comfortable to use, especially when chewing. This article describes the treatment of a flat ridge case in a patient with digestive and nutritional disorders, using the close mouth moulding technique. A 65-year-old woman came to RSGMP Unhas with com-plaints of loose dentures making it difficult to chew, and even had to undergo hospitalisation due to complaints of heartburn so that it was recommended to use a denture by an internal medicine doctor. The patient wanted to make a denture that was firm, comfortable, and improved his appearance. The patient was made an acrylic CD with a close mouth moulding technique. It was concluded that the close mouth moulding technique was effective in producing CDs that were firm, stable, and could restore masticatory function in patients with flat ridge.
Implant supported overdenture using magnetic retention in mandible rehabilitation: Overdenture dukungan implan dengan retensi magnet pada rehabilitasi rahang bawah Muthia Mutmainnah Bachtiar; Irfan Dammar; Eri Hendra Jubhari; Irsal Wahyudi
Makassar Dental Journal Vol. 12 No. 3 (2023): Volume 12 Issue 3 Desember 2023
Publisher : Makassar Dental Journal PDGI Makassar

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Komplikasi sering terjadi pada gigi tiruan lengkap rahang bawah sehingga untuk mengatasi masalah retensi dan stabilitas digunakan implan sebagai dukungan implan overdenture. Sistem attachment yang menghubungkan implan dan overdenture sangat bervariasi, salah satunya dengan sistem magnet. Artikel ini melaporkan penggunaan retensi magnet pada overdenture dukungan implan sebagai rehabilitasi edentulus totalis pada rahang bawah. Seorang laki-laki berusia 53 tahun datang ke Departemen Prostodontik RSGM Unhas dengan keluhan sulit mengunyah makanan karena kehilangan seluruh gigi RA dan RB, pasien ingin dibuatkan gigi tiruan yang tidak mudah lepas sehingga dapat berfungsi dengan baik saat makan. Dilakukan pemasangan implan pada kedua sisi RB sebagai dukungan overdenture, oseointegrasi implan dinilai dan dilanjutkan dengan pemasangan attachment magnet pada bagian implan dan permukaan dalam GTL. 2-IOD memberikan hasil yang dapat meningkatkan fungsi rongga mulut pasien, memberikan stabilitas dan retensi yang baik bagi tiruan sehingga performa mastikasi meningkat. Disimpulkan bahwa penggunaan dua implan pada RB ditambah dengan sistem attachment magnet dapat meningkatkan retensi dan stabilitas pada penggunaan gigi tiruan overdenture.