Pengaruh Variasi Arus Tabung (mA) Terhadap Kualitas Citra Pada Pesawat Computed Tomography (CT) Scan di RSUD Bali Mandara Sintiya Biantari, I Dewa Ayu; Sutapa, Gusti Ngurah; Alit Paramarta, Ida Bagus; Sandi, I Nengah; Suardana, Putu; Tri Suandayani, Ni Komang; Setiawan, Hendra
Kappa Journal Vol 9 No 1 (2025): April
Publisher : Universitas Hamzanwadi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29408/kpj.v9i1.29378

Abstract

Computed Tomography (CT) Scan is one of the essential diagnostic tools in the medical field. CT scan image quality is represented by the Signal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR). This study was conducted to understand the effect of tube current variation on image quality in CT scan examinations. The CT scan parameters were set at an X-ray tube voltage of 120 kV, an exposure time of 1 second, and tube current variations of 100 mA, 200 mA, 300 mA, 400 mA, and 500 mA. From 25 image data obtained from scanning the Tos phantom on the CT scan, data were collected on the average signal intensity of the material, the average signal intensity of the background, and the standard deviation of the background signal intensity obtained from the Region of Interest (ROI) readings on each scanned phantom image. The Pearson correlation test results between tube current and SNR values showed that the Pearson correlation coefficient for polypropylene, nylon, acrylic, delrin, and air were 0.993, 0.992, 0.993, 0.992, and 0.992, respectively. The linear regression correlation coefficient (r) for polypropylene, nylon, acrylic, delrin, and air were also 0.993, 0.992, 0.993, 0.992, and 0.992, respectively. Similarly, the Pearson correlation test results between tube current and CNR values showed that the Pearson correlation coefficient for polypropylene, nylon, acrylic, delrin, and air were 0.992, 0.992, 0.993, 0.992, and 0.992, respectively. The linear regression correlation coefficient (r) for polypropylene, nylon, acrylic, delrin, and air were also 0.992, 0.992, 0.993, 0.992, and 0.992, respectively. These results indicate that for all phantom materials, the tube current value has a strong positive correlation with both SNR and CNR. The SNR and CNR values increase linearly with increasing tube current, suggesting that a higher tube current can improve CT scan image quality.  
Analisis Dosis Serap pada Pemeriksaan Thorax Pasien Anak dengan Pesawat Sinar-X di Instalasi Radiologi RSUD Sanjiwani Gianyar Br Barus, Ema Vinesia; Ratini, Ni Nyoman; Trisnawati, Ni Luh Putu; Sandi, I Nengah; Wendri, Nyoman; Alit Paramarta, Ida Bagus
Kappa Journal Vol 9 No 2 (2025): Agustus
Publisher : Universitas Hamzanwadi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29408/kpj.v9i2.30101

Abstract

Telah dilakukan penelitian mengenai analisis dosis serap pada pemeriksaan thorax pasien anak dengan pesawat sinar-X di Instalasi Radiologi RSUD Sanjiwani Gianyar. Penelitian ini bertujuan untuk menganalisis dosis serap yang diterima oleh pasien anak pada pemeriksaan thorax serta membandingkannya dengan batas dosis yang direkomendasikan oleh United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). Penelitian ini dilakukan dengan metode kuantitatif menggunakan data sekunder dari hasil pemeriksaan thorax pasien anak berusia 1-15 tahun yang meliputi faktor eksposi (tegangan tabung, kuat arus, dan waktu eksposi). Data ini yang kemudian digunakan untuk menghitung dosis paparan dan dosis serap. Analisis statistik dilakukan dengan uji Kruskall-Wallis untuk menentukan signifikansi perbedaan dosis serap di RSUD Sanjiwani Gianyar dengan dosis serap yang ditetapkan oleh UNSCEAR. Hasil penelitian menunjukkan bahwa terdapat variasi dosis serap berdasarkan kelompok usia, di mana semakin tinggi usia pasien, semakin besar dosis serap yang diterima. Didapatkan dosis serap untuk kelompok usia 1-4 tahun yaitu:  mGy untuk pasien laki-laki dan  mGy untuk pasien perempuan. Untuk kelompok usia 5-9 tahun didapatkan sebesar mGy untuk pasien laki-laki dan  mGy untuk pasien perempuan. Sedangkan dosis serap kelompok usia 10-15 didapatkan sebesar  mGy untuk pasien laki-laki dan  mGy untuk pasien perempuan. Dosis serap yang diperoleh di RSUD Sanjiwani masih berada di bawah batas dosis maksimum yang ditetapkan oleh UNSCEAR yaitu: untuk kelompok usia 1-4 tahun sebesar 0,0300 mGy, kelompok usia 5-9 tahun sebesar 0,0400 mGy, dan kelompok usia 10-15 sebesar 0,0500 mGy.