Prananto, Haryo Dwi
Unknown Affiliation

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

KARAKTERISTIK MAGNETIC LOOP PROBE POLIGONAL SEBAGAI APLIKASI PENGUKURAN NEAR FIELD Prananto, Haryo Dwi; Wibowo, Priyo; Wijanarko, Tyas Ari Wahyu; Ardiatna, Wuwus; Arjadi, R. Harry
Simetris: Jurnal Teknik Mesin, Elektro dan Ilmu Komputer Vol 11, No 1 (2020): JURNAL SIMETRIS VOLUME 11 NO 1 TAHUN 2020
Publisher : Fakultas Teknik Universitas Muria Kudus

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (773.096 KB) | DOI: 10.24176/simet.v11i1.3941

Abstract

Pada pengujian kompatibilitas elektromagnetik khususnya pada pengukuran near field, pengukuran medan magnet sangat diperlukan. Salah satu alat pengukuran yang digunakan adalah magnetic loop probe.  Penelitian ini dilakukan untuk membandingkan loop probe pada jumlah sisi geometrinya, dan belum ada referensi yang membahas tentang topik ini. Magnetic loop probe didesain dalam tujuh bentuk geometri yaitu bentuk segi 3 (ada dua model), segi 4, segi 6, segi 8, segi 10, dan segi tak hingga (lingkaran) dimana parameter keliling geometrinya sama. Magnetic loop probe didesain dengan menggunakan perhitungan sebagai small loop antenna Karateristik kelima desain probe dianalisis dengan mengukur S21 sebagai sensitivitas menggunakan Vector Network Analyzer. Karateristik bentuk probe maupun gain dan sensitivitasnya  dibahas dalam makalah ini.
Electromagnetic interference risk from electrostatic discharge in infant incubators Trivida, Elvina; Sudrajat, Muhammad Imam; Ardiatna, Wuwus; Prananto, Haryo Dwi; Nugroho, Hutomo Wahyu; Yoppy, Yoppy; Anam, Mohamad Khoirul; Bakti, Aditia Nur; Mandaris, Dwi; Arjadi, R Harry
Bulletin of Electrical Engineering and Informatics Vol 14, No 2: April 2025
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eei.v14i2.8882

Abstract

This paper proposes an improved electromagnetic compatibility (EMC) risk analysis approach for medical equipment related to the effect of electrostatic discharge (ESD). This approach not only focuses on the risk of ESD from the susceptibility aspect but also investigates its conducted electromagnetic interference (EMI) characteristics. This study combines the standardized ESD test and conducted emission (CE) measurement simultaneously, applying it to the infant incubator and analyzing the spectrum of ESD current in the phase line in the time and frequency domain. The result shows that an ESD exposure caused current spikes with an average level of 13.8 A. Moreover, it also causes a broad spectral CE noise on the phase line of the infant incubator. Furthermore, the CE noise in the low-frequency range was also detected on the phase line during ESD exposure, indicating the risk of interference with other sensitive medical equipment connected to the same power network. The approach of proposed risk analysis in this study can be used to identify the risks of EMI due to ESD events in implementing the latest IEC 60601-1-2.