Passive magnetic coil design for electromagnetic interference evaluation of axle counters Yoppy, Yoppy; Yudhistira, Yudhistira; Nugroho, Hutomo Wahyu; Trivida, Elvina; Wahyu Wijanarko, Tyas Ari; Bakti, Aditia Nur; Mandaris, Dwi
International Journal of Electrical and Computer Engineering (IJECE) Vol 14, No 1: February 2024
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijece.v14i1.pp166-174

Abstract

Measurement of magnetic fields near the railway tracks is crucial to ensure compatibility with the operation of axle counters. According to EN 50592 standard, the magnetic field is detected with a passive magnetic coil and an oscilloscope. From previous studies, in general, there has been no in-depth analysis of how the choice of coil winding parameters could affect the coil output voltage, which then affect the measurement sensitivity, in particular the coil design based on the standard and it is applicability for electromagnetic interference (EMI) evaluation of axle counters. Therefore, this paper will explore the design of a passive magnetic coil to obtain the optimum coil output voltage within the frequency range. Simulations showed that for 10-100 kHz and 100 kHz–1.3 MHz range, the optimum number of turns happened at 60-100 and 15-60 turns, respectively. Based on that, two example coils had been built. Simulations and measurements of their frequency response were in good agreement, with a deviation less than 1.0 dB.
Estimating the Differential Mode Noise of a DC-DC Converter Yoppy, Yoppy; Mandaris, Dwi; Bakti, Aditia Nur; Nugroho, Hutomo Wahyu; Yudhistira, Yudhistira; Hamdani, Deny
Jurnal Elektronika dan Telekomunikasi Vol 23, No 2 (2023)
Publisher : National Research and Innovation Agency

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55981/jet.558

Abstract

Electromagnetic noise emission is inevitable in a DC-DC converter due to the employed switching technique. In low frequency, the noise propagating through cabling and conductive media is called a conducted emission. A conducted emission consists of differential mode and common mode noise. It is advantageous to know an estimate of emission level for each mode during the design phase so that suitable mitigation can be included earlier.. This paper aims to focus on a method to estimate the differential mode noise emission of a DC-DC converter. The estimation is computed using the input capacitor complex impedance and the current that flows through it. As a study case, a boost and buck converters are used for evaluation. The estimation and measurement results are compared. Despite differences at some frequencies, the estimated and measured results generally  agree well. Because of its simplicity, the proposed method can be used as a practical tool in the EMC aspect of DC-DC converter design.
Catalytic Hydroconversion of Lauric Acid Over Poly(N-vinyl-2-pyrrolidone)-Coated Pd Nanoparticles on ZIF-8 Dahnum, Deliana; Ramadhita, Holanda; Andreas, Andreas; Prasetyo, Joni; Bakti, Aditia Nur; Dang, Huyen Tran
Bulletin of Chemical Reaction Engineering & Catalysis 2024: BCREC Volume 19 Issue 1 Year 2024 (April 2024)
Publisher : Masyarakat Katalis Indonesia - Indonesian Catalyst Society (MKICS)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.9767/bcrec.20114

Abstract

A subclass of Metal-Organic Frameworks, Zeolitic Imidazole Frameworks-8 (ZIF-8) is known as an emerging material that has the characteristic of a large surface area, good thermal stability as well as a high porosity. Instead of having extraordinary properties, ZIF-8 consists of Lewis acid and Lewis base site on its Zn metals and 2-methylimidazole which are the important components for the catalyst. In this study, Pd-Poly(N-vinyl-2-pyrrolidone) coated on ZIF-8 (Pd-PVP@ZIF-8) was synthesized by mixed Pd-PVP solution and ZIF-8 precursors at room temperature. The Pd-PVP solution was varied from 10 to 50 ml to differentiate the Pd concentration in ZIF-8. As-synthesized 50 ml of Pd-PVP on ZIF-8 (50Pd-PVP@ZIF-8) showed catalytic activity in the conversion of 98.6% lauric acid to produce 78.2% of 1-dodecanol at optimum condition 320 °C for 6 h. The synergy between Pd-PVP as metal and ZIF-8 as metal support as well as high dispersion of Pd particles could enhance performance in the conversion of lauric acid. Copyright © 2024 by Authors, Published by BCREC Publishing Group. This is an open access article under the CC BY-SA License (https://creativecommons.org/licenses/by-sa/4.0).
Electromagnetic interference risk from electrostatic discharge in infant incubators Trivida, Elvina; Sudrajat, Muhammad Imam; Ardiatna, Wuwus; Prananto, Haryo Dwi; Nugroho, Hutomo Wahyu; Yoppy, Yoppy; Anam, Mohamad Khoirul; Bakti, Aditia Nur; Mandaris, Dwi; Arjadi, R Harry
Bulletin of Electrical Engineering and Informatics Vol 14, No 2: April 2025
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eei.v14i2.8882

Abstract

This paper proposes an improved electromagnetic compatibility (EMC) risk analysis approach for medical equipment related to the effect of electrostatic discharge (ESD). This approach not only focuses on the risk of ESD from the susceptibility aspect but also investigates its conducted electromagnetic interference (EMI) characteristics. This study combines the standardized ESD test and conducted emission (CE) measurement simultaneously, applying it to the infant incubator and analyzing the spectrum of ESD current in the phase line in the time and frequency domain. The result shows that an ESD exposure caused current spikes with an average level of 13.8 A. Moreover, it also causes a broad spectral CE noise on the phase line of the infant incubator. Furthermore, the CE noise in the low-frequency range was also detected on the phase line during ESD exposure, indicating the risk of interference with other sensitive medical equipment connected to the same power network. The approach of proposed risk analysis in this study can be used to identify the risks of EMI due to ESD events in implementing the latest IEC 60601-1-2.