Claim Missing Document
Check
Articles

Found 12 Documents
Search

Evaluation of optimal time blending process on medripal 412 And Prima XP SAE 20W – 50 samples with homogenity test Asminah, Ninin; Prasetyo, Elli; Dhamayanthie, Indah
Gema Wiralodra Vol. 14 No. 2 (2023): gema wiralodra
Publisher : Universitas Wiralodra

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31943/gw.v14i2.431

Abstract

Prima XP SAE 20W - 50 is a multigrade lubricant used for gasoline and Medripal 412 engine lubricants used for marine industry engines which are non-carcinogenic and environmentally friendly. The main factor in testing lubricants is the Blending process, which is the process of mixing base oil with additives. In the blending process, an inhomogeneous lubricant was found which caused the lubricant test not to comply with specifications. This experiment aims to determine the optimal time of the blending process with the KAN homogeneity test method. Homogeneity testing can be seen from the viscosity value of the lubricant. So the optimum time for the blending process is needed for the continuity of the production process of this lubricant. Medripal 412 products have an optimum blending time of 30 minutes with a viscosity value at 100 C ranging from 14.79 mm2 / s based on the SNI 7069.1 Th. 2012, the product specification value of Medripal 412 is 12.5 - <16.3 mm2 / s and the Prima XP SAE 20W - 50 product has an optimum blending time of 45 minutes with a viscosity value at 100oC of 20.28 mm2 / s based on the SNI 7069.1 Th. 2012, the value of the Prima XP SAE 20W - 50 product specification is 5.6 - <21.9 mm2 / s. This shows that the lubricant is by the standard quality standards set by the company and the government so that the lubricant product is still suitable for use.
THE EFFECT OF TEMPERATURE AND WATER CONDUCTIVITY IN HOT BASIN TOWARD EFFECTIVENESS OF COOLING TOWER ON UTILITY UNIT PT. X Dhamayanthie, Indah; Mulyani, Yully
Journal of Green Science and Technology Vol 7 No 1 (2023): JOURNAL OF GREEN SCIENCE AND TECHNOLOGY VOL.7 NO.1 MARET 2023
Publisher : Faculty of Engineering, Universitas Swadaya Gunung Jati

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33603/jgst.v7i1.11

Abstract

PT X is one of the Reviews largest ethanol producing plant in Indonesia, PT X located ± 15 km the northeast of Solo or 110 Km to the south of Central Java, SeAprilang. Cooling Tower is a tower or building of water circulation directly or indirectly contact with hot water and then converted into cold water expected that a number of heat from a fluid to another fluid. The Cooling Tower operates According to the diffusion principle, where temperature changes can result in a difference in the rate of temperature displacement. From the process in the cooling tower unit there are Several variables contained in the cooling towers ranging from the temperature and water conductivity in the hot basin. Obtained from the variables can be used to analyze the effectiveness of the cooling tower unit. When the conductivity contained in the water in the basin of hot high then the effectiveness of cooling tower will Decrease, likewise vice versa. And the value of effectiveness Obtained range of 76.12% - 87.80%. Where the company's standard value is 75% effectiveness. There are Several factors Determining the high value of conductivity values such as chemical mixing, high temperature in the cooling tower, and the temperature around the cooling tower.