Kajian Unjuk Kerja Beban Tidak Seimbang Pada Trafo Open Delta Pelpinus Sinay
JURNAL SIMETRIK Vol 7, No 1 (2017)
Publisher : Pusat Penelitian dan Pengabdian Kepada Masyarakat (P3M) Politeknik Negeri Ambon

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (216.354 KB) | DOI: 10.31959/js.v7i1.174

Abstract

Transformator (trafo) adalah suatu alat yang dapat memindahkan (menyalurkan) dan mengubah energi listrikdari satu rangkaian ke rangkaian listrik yang lain dengan frekuensi yang sama berdasarkan prinsip induksielektromagnetik.Trafo yang akan digunakan dalam penelitian ini adalah trafo tiga fasa hubungan open delta,yang disambung dengan beban terhubung delta. Jika salah satu dari belitan tiga fasa pada trafo hubungan deltamengalami kerusakan, maka sisa dua belitan lainnya dapat diimplementasikan atau dirancang menjadi tiga fasahubungan open delta, yang dapat difungsikan untuk menyalurkan daya listrik tiga fasa ke beban. Unjuk kerjayang dimiliki dari pengaruh beban tidak seimbang pada trafo open delta, saat dibebani dengan beban tidakseimbang yang tidak sama besar pada setiap fasa, menyebabkan terjadi kenaikan arus pada setiap fasa, sehinggaterjadi kenaikan daya input yang diserap oleh beban tidak seimbang mengakibatkan rugi daya (loses) yang lebihbesar dengan efisiensi yang mengecil.Tujuan penelitian adalah kajian unjuk kerja beban tidak seimbang padatrafo open delta dan Metode penelitian adalah metode eksperimen pada laboratorium, yang meliputi pengujianpada trafo tiga fasa hubungan open delta dalam keadaan beban tidak seimbang. Hasil pengukuran menunjukanbahwa terdapat perbedaan unjuk kerja (hasil keluran) pengaruh dari beban tidak seimbang antara rata- rata arusdengan loses maupun dengan efisiensi pada trafo open delta.
KAJIAN INVESTASI PEMAKAIAN SUMBER SOLAR CELL DIBANDINGKAN DENGAN GENSET MENGGUNAKAN LAMPU COMPECT FLUORESCENT Pelpinus Sinay
Jurnal ELKO (Elektrikal dan Komputer) Vol 4, No 1 (2023)
Publisher : Politeknik Negeri Ambon

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54463/je.v4i1.76

Abstract

Teknologi penerangan jalan umum dengan menggunakan lampu compect fluorescent dengan  sumber solar cell yang dibandingkan dengan sumber genset  menjadi sebuah alternatif khusus yang perlu dibahas, karena belum tersedianya rencana anggaran oleh pihak PLN untuk pengadaan penerangan jalan umum secara merata, agar dapat membantu aktifitas masyarakat dimalam hari. Penerapan Penerangan Jalan Umum (PJU) dengan genset memerlukan biaya baban bakar sedangkan  solar cell dari energi matahari dapat diperoleh dalam jumlah yang cukup besar, tidak menimbulkan polusi, dan dapat mengatasi krisis energi listrik  pada masyarakat di daerah terpencil yang belum menikmati penerangan jalan umum. Oleh karena itu dilakukan penelitian untuk mengetahui efisiensi penggunaan pemakaian lampu compect fluorescent menggunakan sumber solar cell yang dibandingkan dengan genset. Setelah dilakukan kajian investasi dari segi bebannya, maka efisiensi PJU dengan sumber solar cell menggunakan lampu compact fluorescent  lebih sedikit bila dibandingkan dengan lampu compact fluorescent dengan sumber genset. Sehingga dapat dijadikan sebagai acuan untuk perencanaan pemasangan lampu penerangan jalan dan menjadi solusi yang tepat dalam mengatasi kebutuhan penerangan jalan umum, bagi masyarakat di daerah pedesaan.
KAJIAN UNJUK KERJA BEBAN TIDAK SEIMBANG PADA TRAFO DELTA Pelpinus Sinay; Marselin Jamlaay
Jurnal ELKO (Elektrikal dan Komputer) Vol 4, No 1 (2023)
Publisher : Politeknik Negeri Ambon

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54463/je.v4i1.78

Abstract

Transformator (trafo) adalah suatu alat yang dapat memindahkan (menyalurkan) dan mengubah energi listrik dari satu rangkaian ke rangkaian listrik yang lain dengan frekuensi yang sama berdasarkan prinsip induksi elektromagnetik. Trafo yang akan digunakan dalam penelitian ini adalah trafo tiga fasa hubungan  delta., yang dapat difungsikan untuk menyalurkan daya listrik tiga fasa ke beban, yang tersambung dengan beban terhubung delta. Unjuk kerja yang dimiliki dari pengaruh beban tidak seimbang pada  trafo open delta, saat dibebani dengan beban tidak seimbang yang tidak sama besar pada setiap fasa, menyebabkan terjadi kenaikan arus pada setiap fasa, sehingga terjadi kenaikan daya input yang diserap oleh beban tidak seimbang mengakibatkan rugi daya (loses) yang lebih besar dengan efisiensi yang mengecil. Tujuan penelitian adalah kajian unjuk kerja  beban tidak seimbang pada trafo delta dan Metode penelitian adalah metode eksperimen pada laboratorium, yang meliputi pengujian pada trafo tiga fasa hubungan delta dalam keadaan beban tidak seimbang. Hasil pengukuran menunjukan bahwa terdapat perbedaan unjuk kerja (hasil keluran) pengaruh dari beban tidak seimbang antara rata- rata arus dengan loses maupun dengan efisiensi pada trafo delta.
Kajian Investasi Pemakaian Lampu Led Dibandingkan Dengan Lampu Flourescent Menggunakan Solar Cell Sinay, Pelpinus
Jurnal Penelitian Multidisiplin Bangsa Vol. 1 No. 9 (2025): Februari
Publisher : Amirul Bangun Bangsa Publishing

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59837/jpnmb.v1i9.326

Abstract

Teknologi penerangan jalan umum dengan sumber solar cell menjadi sebuah alternatif  khususnya untuk daerah–daerah yang jauh dari jalur PLN atau dengan sumber genset yang  masih membutuhkan biaya untuk bahan bakarnya. Penerapan PJU solar cell memiliki banyak keuntungan, karena energi matahari  dapat diperoleh dalam jumlah yang cukup besar, tidak menimbulkan polusi, dan tidak memerlukan biaya untuk mendapatkannya. Oleh karena itu dilakukan penelitian untuk membandingkan nilai ekonomis dari biaya investasi dan operasional pemakaian solar cell dan mengetahui efisiensi penggunaan energi lampu LED dibandingkan dengan lampu flurorescent. Setelah dilakukan kajian, maka untuk perhitungan biaya investasi dan operasional pemakaian PJU lampu Led dengan sumber Solar Cell lebih ekonomis, sehingga dapat dijadikan sebagai acuan untuk perencanaan pemasangan lampu penerangan jalan dan menjadi solusi yang tepat dalam mengatasi kebutuhan penerangan jalan umum.
Kajian Motor Tak Serempak Tiga Phasa sebagai Generator Satu Phasa dalam Penerapan Teknologi Efisiensi Energi Pelpinus Sinay
Mars : Jurnal Teknik Mesin, Industri, Elektro Dan Ilmu Komputer Vol. 3 No. 4 (2025): Agustus : Jurnal Teknik Mesin, Industri, Elektro Dan Ilmu Komputer
Publisher : Asosiasi Riset Teknik Elektro dan Informatika Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61132/mars.v3i4.1023

Abstract

Asynchronous motors, commonly known as induction motors, are widely utilized due to their robustness, reliability, and efficiency in both industrial and household applications. These motors typically operate by converting electrical energy into mechanical energy through the interaction between a rotating magnetic field and the rotor. Under normal operating conditions, the rotor speed is always slightly less than the speed of the magnetic field, which is known as "slip." However, when the slip becomes negative, meaning that the rotor speed exceeds the speed of the rotating magnetic field, the motor begins to function as a generator. This condition occurs when the motor is driven above its synchronous speed by an external mechanical force, causing the rotor to generate electrical power. Using an asynchronous motor as a generator offers several notable advantages. One of the key benefits is its ability to produce a pure sine wave voltage, which is crucial for various applications that require stable and high-quality electrical power. Since these motors do not use brushes, they are free from the problems associated with brush wear and maintenance. Moreover, they do not generate radio frequency interference (RFI), making them suitable for environments sensitive to electromagnetic disturbances. The use of an asynchronous motor as a generator also provides the ability to function as a rotary phase converter. This is especially beneficial in applications where three-phase power is unavailable, but the load requires it. To facilitate this process, a capacitive voltage is required to induce excitation in the rotor. The capacitive current is supplied by an additional capacitor, which is installed in parallel with the motor output. This capacitor helps maintain the necessary phase shift and enables the motor to generate the required three-phase power.
PERFORMANCE STUDY OF UNBALANCED LOAD ON OPEN DELTA TRANSFORMERS Pelpinus Sinay
International Journal Multidisciplinary Science Vol. 2 No. 3 (2023): October: International Journal Multidisciplinary Science
Publisher : Asosiasi Dosen Muda Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56127/ijml.v2i3.1252

Abstract

A transformer is a device that can transfer (transmit) and change electrical energy from one electrical circuit to another with the same frequency based on the principle of electromagnetic induction. The transformer that will be used in this research is a three-phase open delta connection transformer, which is connected to a delta connected load. If one of the three phase windings in the delta connection transformer is damaged, then the remaining two windings can be implemented or designed into three phase open delta connections, which can be used to distribute three phase electrical power to the load. The performance of the unbalanced load influence on the open delta transformer, when it is loaded with an unbalanced load that is not the same size on each phase, causes an increase in current on each phase, resulting in an increase in the input power absorbed by the unbalanced load resulting in power loss. larger (losses) with reduced efficiency. The aim of the research is to study the performance of unbalanced loads on open delta transformers and the research method is an experimental method in the laboratory, which includes testing on three-phase open delta transformers in unbalanced load conditions. The measurement results show that there are differences in performance (output results) in the influence of unbalanced loads between the average current and losses and the efficiency of the open delta transformer.
Performance Study of Unbalanced Load on Delta Transformer Sinay, Pelpinus
International Journal Multidisciplinary Science Vol. 5 No. 1 (2026): February: International Journal Multidisciplinary Science
Publisher : Asosiasi Dosen Muda Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56127/ijml.v5i1.2592

Abstract

A transformer is a device that can transfer (channel) and convert electrical energy from one circuit to another at the same frequency based on the principle of electromagnetic induction. The transformer to be used in this study is a three-phase delta connection transformer, which can be used to transmit three-phase electrical power to the load, which is connected to the delta-connected load. The performance of the unbalanced load on the open delta transformer, when loaded with an unbalanced load that is not the same size in each phase, causes an increase in current in each phase, so that there is an increase in input power absorbed by the unbalanced load resulting in greater power losses (loses) with reduced efficiency. The purpose of the study is to study the performance of unbalanced loads in delta transformers and The research method is an experimental method in the laboratory, which includes testing on three-phase transformers of delta connection in an unbalanced load state. The measurement results showed that there was a difference in the performance (yield of the discharge) effect of the unbalanced load between the average current with the loss and with the efficiency of the delta transformer.
Kajian Unjuk Kerja Beban Tidak Seimbang Pada Trafo Open Delta Sinay, Pelpinus
JURNAL SIMETRIK Vol 7 No 1 (2017): Jurnal Simetrik (Sipil, Mesin, Listrik)
Publisher : Pusat Penelitian dan Pengabdian Kepada Masyarakat (P3M) Politeknik Negeri Ambon

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31959/js.v7i1.174

Abstract

Transformator (trafo) adalah suatu alat yang dapat memindahkan (menyalurkan) dan mengubah energi listrikdari satu rangkaian ke rangkaian listrik yang lain dengan frekuensi yang sama berdasarkan prinsip induksielektromagnetik.Trafo yang akan digunakan dalam penelitian ini adalah trafo tiga fasa hubungan open delta,yang disambung dengan beban terhubung delta. Jika salah satu dari belitan tiga fasa pada trafo hubungan deltamengalami kerusakan, maka sisa dua belitan lainnya dapat diimplementasikan atau dirancang menjadi tiga fasahubungan open delta, yang dapat difungsikan untuk menyalurkan daya listrik tiga fasa ke beban. Unjuk kerjayang dimiliki dari pengaruh beban tidak seimbang pada trafo open delta, saat dibebani dengan beban tidakseimbang yang tidak sama besar pada setiap fasa, menyebabkan terjadi kenaikan arus pada setiap fasa, sehinggaterjadi kenaikan daya input yang diserap oleh beban tidak seimbang mengakibatkan rugi daya (loses) yang lebihbesar dengan efisiensi yang mengecil.Tujuan penelitian adalah kajian unjuk kerja beban tidak seimbang padatrafo open delta dan Metode penelitian adalah metode eksperimen pada laboratorium, yang meliputi pengujianpada trafo tiga fasa hubungan open delta dalam keadaan beban tidak seimbang. Hasil pengukuran menunjukanbahwa terdapat perbedaan unjuk kerja (hasil keluran) pengaruh dari beban tidak seimbang antara rata- rata arusdengan loses maupun dengan efisiensi pada trafo open delta.