Claim Missing Document
Check
Articles

Found 3 Documents
Search

Box-Behnken Experimental Design for Electrochemical Aptasensor Optimization on Screen Printed Carbon Electrode/Silica-Ceria Zakiyyah, Salma Nur; Eddy, Diana Rakhmawaty; Firdaus, Muhammad Lutfi; Subroto, Toto; Hartati, Yeni Wahyuni
Jurnal Kimia Valensi Jurnal Kimia VALENSI Volume 9, No. 1, May 2023
Publisher : Syarif Hidayatullah State Islamic University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15408/jkv.v9i1.27493

Abstract

This study aims to optimize the epithelial sodium channel (ENaC) electrochemical aptasensor with the Box-Behnken experimental design. ENaC is a protein that plays a role in sodium ion transport in several epithelial tissues and is associated with hypertension. The ENaC protein aptamer is held in place in the electrochemical aptasensor by a modified screen-printed carbon electrode (SPCE) of silica-ceria composite (SiO2-CeO2). The unique structure of a silica matrix with high biocompatibility can form composites through a hydrothermal process. The Box-Behnken (BBD) experimental design is an efficient optimization method of factors that affect the experiment at three levels. The FTIR results of the silica-ceria composites were 549.35 cm-1 (Ce-O), 1095.3 cm-1 (Si-O-Si), and 491.28 cm-1 (Si-O). Meanwhile, SPCE/silica-ceria characterized by differential pulse voltammetry (DPV) showed an increase in peak current [Fe(CN)6]3-/4- from 3.190 μA to 9.073 μA. Three experimental factors, aptamer concentration, streptavidin incubation time, and aptamer incubation time, were optimized with BBD and obtained at 0.5 μg.mL-1, 30 minutes, and 1 hour. The optimum conditions observed resulted in a selective current response for ENaC protein detection. The optimization results can be applied to aptamer-based ENaC protein detection in samples.
Electrochemical Sensor and Biosensor Detection of Ethanol in Beverage Samples: Irkham, Irkham; Zalfadilah, Faizal Nur; Zein, Muhammad Ihda Hamlu Liwaissunati; Khaerani, Wulan; Zakiyyah, Salma Nur; Hartati, Yeni Wahyuni
Journal of Advanced Technology and Multidiscipline Vol. 4 No. 1 (2025): Journal of Advanced Technology and Multidiscipline
Publisher : Faculty of Advanced Technology and Multidiscipline Universitas Airlangga

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20473/jatm.v4i1.71985

Abstract

Ethanol detection is critical in the beverage industry, where it is essential to monitor alcohol concentrations for quality control and compliance with regulatory standards. Traditional analytical methods, such as gas chromatography and distillation, offer accuracy but are often labor-intensive, time-consuming, and require sophisticated equipment. In contrast, electrochemical sensors and biosensors have emerged as promising alternatives due to their rapid response, portability, cost-effectiveness, and potential for real-time monitoring. Electrochemical sensors, particularly those enhanced with metal nanoparticles like platinum, palladium, or gold, have shown significant improvements in sensitivity, selectivity, and response time. These sensors offer the advantage of miniaturization, making them ideal for on-site analysis, although issues such as electrode stability, susceptibility to interference, and long-term reliability remain. On the other hand, biosensors, which leverage biorecognition elements like alcohol dehydrogenase (ADH) or alcohol oxidase, provide high specificity for ethanol, reducing interference from other compounds commonly found in beverage samples. Recent advancements in biosensor technology have focused on improving sensor stability, enzyme immobilization techniques, and reducing production costs. While biosensors offer high selectivity and sensitivity, they may still face challenges related to enzyme denaturation and environmental factors such as temperature and pH fluctuations. Both electrochemical sensors and biosensors are continuously evolving, with recent developments including the use of nanomaterials and novel biorecognition elements to enhance performance. This review will explore recent advances in electrochemical sensors and biosensors for ethanol detection in beverage samples, highlighting their potential, challenges, and future directions in this field.
Direct Electrochemical Detection of Carbaryl in Water using Boron-Doped Diamond Electrodes Fransisca, Natasha; Putra, Chico Permana; Zakiyyah, Salma Nur; Zein, Muhammad Ihda Hamlu Liwaissunati; Hartati, Yeni Wahyuni; Irkham, Irkham
Chimica et Natura Acta Vol 14, No 2 (2026)
Publisher : Departemen Kimia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24198/cna.v14.n2.72780

Abstract

Carbaryl (1-naphthyl methylcarbamate) is a carbamate pesticide used to cause adverse environmental and health effects when misused through water contamination. Therefore, this research aimed to develop a direct electrochemical detection method for carbaryl in aqueous media using boron-doped diamond (BDD) electrodes. In this context, BDD electrodes exhibited superior electrochemical performance compared to conventional materials such as gold (Au), platinum (Pt), and glassy carbon electrodes (GCE) due to a wide potential window, low background current, and excellent chemical stability. Cyclic and differential pulse voltammetry reported a well-defined oxidation peak for carbaryl at 1.30 V, with significantly enhanced sensitivity. The results showed that there was a linear response in the concentration range of 10–100 μM, with a detection limit of 5.30 μM, quantification limit off 100.69 μM, excellent reproducibility (RSD = 2.35%) and recovery (100.97%). Furthermore, SEM and Raman analyses confirmed the polycrystalline structure and high boron doping level of BDD surface. The method was validated using tap water samples, confirming the applicability for real-world environmental monitoring. These results suggested the potential of BDD electrodes for sensitive, rapid, and direct detection of carbaryl in water without the need for complex sample preparation.