Claim Missing Document
Check
Articles

Found 3 Documents
Search

PENGARUH TINGKAT PENGETAHUAN DAN SIKAP PERAWAT TERHADAP PENERAPAN STANDAR PROSEDUR OPERASIONAL (SPO) PEMASANGAN INFUS DI RS PKU MUHAMMADIYAH BANTUL 'Aini, Qurratul; Firdaus, Muhammad
JMMR (Jurnal Medicoeticolegal dan Manajemen Rumah Sakit) Vol 3, No 1 (2014): January
Publisher : Universitas Muhammadiyah Yogyakarta in Clollaboration with ADMMIRASI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/jmmr.v3i1.967

Abstract

Most of action for infusion in the emergency department. Action of infusion more frequently performed by nurses and should be in accordance with standard operating procedures (SOP). The occurrence of plebitis incident, swollen, and trauma of due to repeated infusion is result of actions that do not prioritize of the patient safety. The purpose of research is knowing influence the level of knowledge and attitudes of nurses toward the implementation of Standard Operating Procedures in infusion. This research used descriptive quantitative research methods with cross sectional. The respondent of it is nurses working in the emergency department of PKU Muhammadiyah Hospital Bantul. Data was collected using a questionnaires and observation. The analytical tool used are univariate, bivariate, and multivariate. Results is the level of knowledge most of nurses in good category (80,00%), the attitude of most of the nurses has a good category (53,33%) and the application of standard operating procedures infusion majority of categories has been implemented (53,33%). There is a relationship between the level of knowledge and the application of standard operating procedures (p0,05). There is a relationship between the attitude and the application of standard operating procedures (p0,05). The magnitude of the influence level of knowledge and attitudes of nurses toward the implementation of SOP for 53,4% (R Square) while the remaining  46,6% is explained by other variables. Conclusion is there is influence between knowledge and attitude toward the implementation of standard operating procedures of infusion in RS PKU Muhammadiyah Bantul. The suggestion is the hospital should be providing the instrument of infusion accordance with the principles of safety and alertness in the application of standard operating procedures of infusion. Keyword: Level of Knowledge, Attitude, Implementation of Standard Operating Procedures of Infusion
PENGARUH KUALITAS JASA PELAYANAN TERHADAP CITRA INSTALASI RADIOLOGI DI RUMAH SAKIT GIGI DAN MULUT PENDIDIKAN UNIVERSITAS MUHAMMADIYAH YOGYAKARTA Umam, Shohibul; Handayani, Siti Dyah; 'Aini, Qurratul
JMMR (Jurnal Medicoeticolegal dan Manajemen Rumah Sakit) Vol 3, No 2 (2014): July
Publisher : Universitas Muhammadiyah Yogyakarta in Clollaboration with ADMMIRASI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/jmmr.v3i2.973

Abstract

Background : RSGM-P UMY already have tools such as the installation of radiological medical support enforcement destined diagnose oral disease. Problems that arise sometimes results are not as expected , and response less in service . The purpose of this study to analyze and explain the effect of partial and simultaneous quality radiology services to the installation image in RSGM-P UMY. Method : using quantitative methods , research subjects dentists and coass student in RSGM- P UMY . Installation of radiological research object . Types of studies using cross-sectional data was obtained from questionnaires and analyzed using multiple regression. Results: The regression equation based on existing variables positively influence the assurance (0.069), empathy (0.171), reliability (0.073), responsiveness (0,037), services (0.450), professionalism (0.326) and there was a negative , namely physical appearance (-0.016). Based on the t test of the quality of service simultaneously affect the installation image RSGMP UMY , based on the F test ( Anova : Sig . 0,000 ) is the quality of service simultaneously affect the image RSGMP UMY installation , and test results influence the determination coefficient percentage at 39.5 % . Conclusion: The services quality there are  assurance, empathy , reliability , responsiveness , physical appearance have partial can’t effect on image radiologi installation. Variable  service and professionalism have an influence on the image of radiological installations RSGMP UMY . The variable quality services have an simultan effect on the image of radiological installations RSGMP UMY.Keywords: Quality, Image Radiology Installation
Analysis of the Hydraulic Jump Characteristics in a Stilling Basin to Avoid Dam Failure Fatimah, Eldina; Azmeri, Azmeri; 'Aini, Qurratul; Fauzi, Muhammad; Rizalihadi, Maimun
International Journal of Disaster Management Vol 6, No 1 (2023)
Publisher : TDMRC, Universitas Syiah Kuala

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24815/ijdm.v6i1.31990

Abstract

Flooding may occur due to dam failure at downstream of the spillway. Stilling basin of the spillway plays an important role in reducing turbulence generated by hydraulic jumps. It can avoid flooding and local scouring as well. Therefore, this study aims to analyze hydraulic jump characteristics experimentally. Two series of structures namely initial (S0) and final (S1) were tested. The S0 model is the United States Bureau of Reclamation (USBR) III type, while S1 is set the adverse slope of 1:2 at the downstream and lowering the bottom elevation of the channel by 4 m. Measurements were taken on the length of hydraulic jumps, water level and high speed before-after hydraulic jumps at various return periods discharges (Q) of 2, 5, 10, 25, 50, 100 and 1000 years. It is found that at S1, the jump is submerged, causing the relative hydraulic jump height (y2-y1)/y1 to be 40-90% higher than S0. Furthermore, the compression of more than 50% of the hydraulic jump length ratio (Lj/y2) was indicated at S1. In addition, the energy dissipation efficiency (t) obtained for each discharge at S1 ranged from 58-84% (good absorption). On the other hand, at S0, the t produced was around 70-89% (Q2-Q50) and 45% (Q100 and Q1000). It can be concluded that the modification of USBR III can reduce the vulnerability of the bottom and downstream parts of the stilling basin. It is expected that the potential flood disaster due to the stilling basin failure of the dam can be eliminated. These results may be used as recommendation to the disaster management strategies, such as improving dam safety guidelines, informing emergency response plans, or guiding infrastructure design to withstand hydraulic forces.