Claim Missing Document
Check
Articles

Found 2 Documents
Search

IDENTIFIKASI SOIL TRANSMITTED HELMINT PADA FESES TERNAK BABI MENGGUNAKAN METODE DIRECT SLIDE Solikah, Monika Putri; Widyastuti, Havida
Jurnal Analis Laboratorium Medik Vol 8 No 1 (2023): JURNAL ANALIS LABORATORIUM MEDIK
Publisher : UNIVERSITAS SARI MUTIARA INDONESIA

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/jalm.v8i1.3880

Abstract

Until now, parasitic diseases that infect humans and animals have not been considered in Indonesia because these diseases do not cause clinical symptoms (subclinical). Gastrointestinal disease caused by worm parasites is a systemic disease that attacks the digestive tract of cattle. Traditional pig farming methods and poor hygiene are the main reasons for the spread of zoonoses that can be transmitted from pigs to humans. This study aims to identify nematode hosts by examining worm eggs in pig feces using the direct slide method. From a total of 20 stool samples, 3 samples were positive for nematode worm eggs. A stool sample that is identified as positive for worm eggs determines the level of parasitic infestation. Worm egg detection was carried out in the laboratory of the Faculty of Health Sciences University and analyzed descriptively, then the number of worm eggs was counted to determine the prevalence of endoparasites.
Analisis IQC dan Sigma Metrik Pemeriksaan Bilirubin Total Level Normal di RS Tipe C Kota Yogyakarta Wulandari, Nia; Widyastuti, Havida; Agustin Amalia, Arifiani
TRILOGI: Jurnal Ilmu Teknologi, Kesehatan, dan Humaniora Vol 7, No 3 (2026)
Publisher : Universitas Nurul Jadid

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33650/trilogi.v7i3.16588

Abstract

Background: The implementation of Internal Quality Control is crucial in clinical laboratories to ensure the accuracy and precision of test results, particularly for total bilirubin, which serves as an indicator of hepatobiliary disorders. Objective: This study aimed to analyze Internal Quality Control and sigma metrics for normal-level total bilirubin testing at a Type C hospital in Yogyakarta City by evaluating accuracy, precision, Levey-Jennings charts based on Westgard rules, and sigma metric values. Methods: This was a descriptive study with a quantitative approach utilizing secondary data from A total of 181 daily QC results from January–June 2025 were analyzed. Total sampling was employed. Data were processed using Microsoft Excel to calculate the mean, standard deviation (SD), Coefficient of Variation (CV%), bias (d%), and sigma metric values based on the 2024 CLIA Total Allowable Error (TEa) of 20%. Results: The Coefficient of Variation (CV%) values from January to June were 16.66%, 9.80%, 11.76%, 5.88%, 13.72%, and 10.78%, respectively. Only April met the precision criterion (CV ≤7%). Bias (d%) values were 8.62%, 9.80%, 8.82%, 10.59%, 11.76%, and 7.84%, respectively; all values fell below the Total Allowable Error (TEa) limit, indicating acceptable testing accuracy. Levey-Jennings charts revealed violations of the Westgard 1₂s rule from February to June and the 1₃s rule in May. Sigma metric values from January to June were 0.72, 1.04, 0.95, 1.56, 0.60, and 0.85, respectively. All results fell into the <3 sigma category. Conclusion: Total bilirubin testing demonstrated acceptable accuracy, yet precision was suboptimal. Evaluation of Levey-Jennings charts and sigma metric values indicates that the Internal Quality Control process requires improvement.