UJI KESESUAIAN CT NUMBER IN WATER PADA PESAWAT CT SCAN MERK PHILIP DI INSTALASI RADIOLOGI RSU. BMC PADANG : THE COMPATIBILITY TEST OF CT NUMBER IN WATER ON CT SCAN AIRCRAFT BRAND PHILIP IN RADIOLOGY INSTALLATION OF BMC PADANG GENERAL HOSPITAL Nansih, Livia Ade; Artitin, Cicilia
JURNAL TERAS KESEHATAN Vol 6 No 1 (2023): Jurnal Teras Kesehatan
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat (LPPM) Politeknik Al Islam Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.38215/jtkes.v6i1.105

Abstract

CT number is the value of the X-ray attenuation coefficient determined by the average energy of X-rays and the absorber atomic number is expressed by the attenuation coefficient. The role of the CT number on a CT scan machine to assess and differentiate abnormalities in human organs. Compliance tests are carried out to ensure that the CT-Scan aircraft meets radiation safety requirements and provides precise and accurate diagnostic information. This research is a quantitative research with an experimental approach, carried out at the Radiology Installation of RSU Bunda Padang in June 2022 for 5 days. The population of all CT number tests, samples at five measurement points with ROI in the center of the image, at 12 o'clock, 3 o'clock, 6 o'clock and 9 o'clock directions. Research data was taken by observing, experimenting and documenting. Data analysis was compared with PERKA BAPETEN Number 9 of 2011 concerning quality assurance of QA and QC of CT Scan aircraft. The results showed that the CT number value in the middle of the image on the first day was 4.83 HU, the second was 4.83 HU, the third was 4.14 HU, the fourth was 5.15 HU and the fifth was 5.16 HU while the average standard deviation on the first day was 3, 48 HU, the second day 3.42 HU, the third day 3.41 HU, the fourth day 3.43 HU and the fifth day 3.50 HU, the ROI uniformity results at the image and noise center show that it has exceeded the tolerance limits set by PERKA BAPETEN No. 9 of 2011.
Increasing Radiographers' Knowledge Through Socialization of Research Results Pocket Book in The Radiology Unit of Reksodiwiryo Hospital in Padang Nansih, Livia Ade; Sari, Oktavia Puspita; Chairunnisa, Chairunnisa; Mareta, Santa; Dewilza, Nerifa; Hanifah, Wahdini; Artitin, Cicilia; Yudha, Sagita
MSJ : Majority Science Journal Vol. 2 No. 3 (2024): MSJ-AUGUST
Publisher : PT. Hafasy Dwi Nawasena

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61942/msj.v2i3.234

Abstract

Radiology is a medical science that focuses on imaging technology. with results in the form of images /images for. to establish a diagnosis by looking at parts of the human body using X-rays so as to be able to provide professional examination services. The results of research that have been conducted at Aulia Hospital regarding the selection of CT scanogram settings for head scans with clinical chepalgia using the upper limit of the vertex and the lower limit of the mandibular because the location of the abnormality in the patient is not known whether in the nerve or sinus, if the scanogram is made to the lower limit of the petrous pars it still cuts the cerebrum so that the sinuses are still cut. whereas in the Radiology installation of Reksodiwiryo Padang Hospital uses a scanogram of the lower limit of the cranii base and the upper limit of the vertex to minimize the radiation received by the patient. Based on this, socialization activities through a pocket book of research results were carried out at Reksodiwiryo Padang Hospital on August 10, 2023 starting at 08.00 - 12.00 WIB, with participants being radiographers in the Radiology installation of Reksodiwiryo Padang Hospital.  The methods used were lecture, discussion and question and answer. With communication that is two way traffic, there is a direct reciprocal relationship between the speaker and the participants or vice versa. This method applied can focus the attention of participants in training to develop thinking power and skills to express opinions in the form of exchanging information in solving a problem. The results of the socialization of the pocket book of research results on the effectiveness of CT scan management of the head with clinical chepalgia were 98% able to increase radiographers' knowledge in the selection of scanogram settings on CT scans of the head with chepalgia able to produce images that enforce dignosa
Analisis Faktor Internal Yang Mempengaruhi Kejadian Burnuot Radiografer Di Rumah Sakit Kota Padang Sari, Oktavia Puspita; Mareta, Santa; Rahmadhani, Putri; Artitin, Cicilia
Jurnal Ilmu Kedokteran dan Kesehatan Vol 12, No 8 (2025): Volume 12 Nomor 8
Publisher : Prodi Kedokteran Fakultas Kedokteran Universitas Malahayati

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33024/jikk.v12i8.22017

Abstract

Penelitian ini bertujuan untuk menganalisis faktor-faktor internal yang mempengaruhi kejadian burnout pada radiografer di beberapa rumah sakit di Kota Padang. Burnout merupakan sindrom kelelahan fisik, emosional, dan mental yang sering terjadi pada tenaga kesehatan, termasuk radiografer, akibat dari beban kerja yang berat dan stres berkepanjangan. Penelitian ini menggunakan desain kuantitatif dengan pendekatan cross-sectional yang dilakukan di empat rumah sakit, yaitu Rs A, RS B, RS C, RS D in Padang. Penelitian ini menggunakan sampel sebanyak 58 orang radiografer dengan teknik total sampling. Analisis data dilakukan secara univariat dan bivariat dengan uji chi-square untuk melihat hubungan antara variabel independen (umur, jenis kelamin, pendidikan, lama bekerja, dengan variabel dependen (burnout). Hasil penelitian menunjukkan bahwa 52,2% responden mengalami tingkat burnout yang tinggi. Faktor-faktor yang memiliki hubungan signifikan dengan kejadian burnout adalah umur (p = 0,004), lama bekerja (p = 0,000), desain organisasi/beban kerja (p = 0,002), dukungan rekan kerja (p = 0,017), dan kepemimpinan (p = 0,012). Sementara itu, jenis kelamin dan pendidikan tidak memiliki hubungan yang signifikan dengan burnout. Kesimpulan dari penelitian ini adalah bahwa faktor umur, lama bekerja, beban kerja, dukungan sosial, dan kepemimpinan berpengaruh signifikan terhadap burnout pada radiografer. Penelitian ini dapat menjadi dasar sebagai pembuat kebijakan untuk meningkatkan kualitas kerja dan menurunkan kejadian burnout pada radiografer.
Uji Kesesuaian CT Number In Water Pada Pesawat CT Scan Merk Philip Di Instalasi Radiologi RSU BMC Padang Nansih, Livia Ade; Artitin, Cicilia
JURNAL TERAS KESEHATAN Vol 6 No 1 (2023): Jurnal Teras Kesehatan
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat (LPPM) Politeknik Al Islam Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.38215/jtkes.v6i1.105

Abstract

CT number is the value of the X-ray attenuation coefficient determined by the average energy of X-rays and the absorber atomic number is expressed by the attenuation coefficient. The role of the CT number on a CT scan machine to assess and differentiate abnormalities in human organs. Compliance tests are carried out to ensure that the CT-Scan aircraft meets radiation safety requirements and provides precise and accurate diagnostic information. This research is a quantitative research with an experimental approach, carried out at the Radiology Installation of RSU Bunda Padang in June 2022 for 5 days. The population of all CT number tests, samples at five measurement points with ROI in the center of the image, at 12 o'clock, 3 o'clock, 6 o'clock and 9 o'clock directions. Research data was taken by observing, experimenting and documenting. Data analysis was compared with PERKA BAPETEN Number 9 of 2011 concerning the quality assurance of QA and QC of CT Scan aircraft.