Pengaruh Beban Non-Linier dengan Harmonisa pada Sistem Kelistrikan Gedung Perkantoran terhadap Efisiensi dan Suhu Trafo Distribusi 2500 kVA dengan Simulasi Software ETAP (Studi Kasus PT Pamapersada Nusantara JIEP) Prian Gagani Chamdareno; I Putu Arsa Adi Nugraha; Budiyanto Budiyanto
RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer) Vol. 9 No. 1 (2026): RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer)
Publisher : Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24853/resistor.9.1.47-54

Abstract

ABSTRAK Gedung perkantoran modern memiliki ketergantungan tinggi terhadap peralatan elektronik seperti sistem pendingin udara (AC), komputer, power converter, serta uninterruptible power supply (UPS). Peralatan tersebut umumnya tergolong beban non-linier yang menjadi penyebab utama timbulnya distorsi harmonisa pada sistem tenaga listrik. Distorsi harmonisa dapat menurunkan kualitas daya dan berdampak serius terhadap komponen vital, khususnya transformator distribusi. Efek negatif yang ditimbulkan antara lain penurunan efisiensi operasi, peningkatan suhu kerja, serta berpotensi memperpendek umur pakai transformator. Penelitian ini bertujuan untuk menganalisis pengaruh beban non-linier dan harmonisa terhadap efisiensi serta kondisi termal transformator distribusi berkapasitas 2500 kVA di PT. Pamapersada Nusantara JIEP. Metodologi yang digunakan meliputi pendekatan kuantitatif melalui pengukuran langsung di lapangan serta simulasi berbasis perangkat lunak Electrical Transient Analyzer Program (ETAP). Hasil pengukuran menunjukkan bahwa pada kondisi beban puncak, total distorsi harmonisa arus (THDi) mencapai 21,07%, melebihi batas yang ditetapkan oleh standar IEEE 519-2014. Sementara itu, total distorsi tegangan (THDv) masih berada dalam kategori aman dengan nilai 0,99%. Tingginya THDi secara langsung meningkatkan rugi-rugi daya hingga 16,5 kVA dan menyebabkan kenaikan suhu transformator sebesar 54°C. Melalui simulasi, penerapan filter pasif single-tuned pada harmonisa orde ke-5 dan ke-7 terbukti mampu menurunkan THDi hingga 1,34% serta mengurangi rugi-rugi daya sebesar 70%. Dengan demikian, instalasi filter harmonisa dapat menjadi solusi efektif untuk meningkatkan efisiensi serta keandalan operasi transformator distribusi pada lingkungan gedung perkantoran modern. Kata Kunci : Beban Non-linier, Harmonisa, Transformator Distribusi, Efisiensi, ETAP ABSTRACT Modern office buildings are highly dependent on electronic equipment such as air conditioning (AC) systems, computers, power converters, and uninterruptible power supply (UPS) units. These devices generally represent nonlinear loads that serve as the main source of harmonic distortion in electrical systems. Harmonic distortion reduces power quality and poses significant negative impacts on critical components, particularly distribution transformers. The adverse effects include decreased operational efficiency, elevated operating temperature, and potential reduction of transformer lifespan. This study aims to analyze the influence of nonlinear loads and harmonics on the efficiency and thermal performance of a 2500 kVA distribution transformer at PT. Pamapersada Nusantara JIEP. The research methodology applied a quantitative approach through direct field measurements combined with simulation using the Electrical Transient Analyzer Program (ETAP) software. Measurement results revealed that under peak load conditions, the total harmonic distortion of current (THDi) reached 21.07%, which significantly exceeds the IEEE 519-2014 standard. Meanwhile, total harmonic distortion of voltage (THDv) remained within safe limits at 0.99%. The high THDi value directly contributed to additional power losses of up to 16.5 kVA and caused an increase in transformer temperature by 54°C. Simulation results further demonstrated that the implementation of a single-tuned passive filter targeting the 5th and 7th harmonic orders was highly effective, reducing THDi to 1.34% and lowering power losses by approximately 70%. Therefore, the application of harmonic filters represents an effective solution to enhance efficiency and reliability of distribution transformer operation in modern office building environments. Keywords: Nonlinear Load, Harmonics, Distribution Transformer, Efficiency, ETAP
Peningkatan Kehandalan Trafo Gardu Induk 150/20 kV terhadap Gangguan Through Fault Current dari Sisi Penyulang 20 kV di Wilayah PT PLN (Persero) UIT JBB Nowo Wicaksono; Prian Gagani Chamdareno; Budiyanto Budiyanto; Erwin Dermawan
RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer) Vol. 8 No. 1 (2025): RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer)
Publisher : Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24853/resistor.8.1.37-42

Abstract

ABSTRAK Dalam penyaluran energi litrik, gangguan adalah sesuatu hal yang tidak dapat dihindari. Dalam berbagai macam sumber dan jenis gangguan, terdapat gangguan yang berpotensi merusak peralatan secara permanen. Salah satu gangguan tersebut adalah gangguan through fault current di sistem jaringan 20 kV yang berdampak terhadap trafo yang terpasang di Gardu Induk. Over Current Relay (OCR) sebagai proteksi eksisting di penyulang 20 kV, bertugas untuk memberikan perintah trip PMT Penyulang 20 kV ketika terjadi gangguan, namun ada potensi mala kerja PMT 20 kV yang berakibat menambah durasi gangguan yang dirasakan oleh Trafo. Di dalam penelitian ini akan membahas tentang perubahan skema proteksi antara penyulang dan incoming 20 kV terhadap gangguan Through Fault Current yang akan berdampak terhadap penurunan laju ketahanan trafo terhadap gangguan Through Fault Current. Kata Kunci: Over Current Relay, Through Fault Current, Penyulang, Incoming ABSTRACT In the distribution of electrical energy, disturbances are something that cannot be avoided. In various sources and types of disturbances, there are disturbances that have the potential to permanently damage equipment. One of these disturbances is through fault current disturbances in the 20 kV network system which has an impact on the transformer installed in the Substation. Over Current Relay (OCR) as existing protection in the 20 kV feeder, is tasked with providing a trip command to the 20 kV Feeder PMT when a disturbance occurs, but there is a potential for the 20 kV PMT to malfunction which results in increasing the duration of the disturbance felt by the Transformer. This study will discuss changes in the protection scheme between the feeder and incoming 20 kV against Through Fault Current disturbances which will have an impact on reducing the rate of transformer resistance to Through Fault Current disturbances. Keywords: Over Current Relay, Through Fault Current, Feeder, Incoming
Perancangan Prototipe Sistem Monitoring Status dan Kinerja Genset 5.5 KVA Genset 5.5 KVA Pada Fasilitas Di Tempat Terpencil Prian Gagani Chamdareno; Ilham Gilang Permana; Budiyanto Budiyanto; Eka Samsul Ma'arif; Sumardi Saidi
RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer) Vol. 8 No. 2 (2025): RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer)
Publisher : Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24853/resistor.8.2.119-128

Abstract

Genset adalah salah satu penyedia listrik sekunder pada fasilitas yang jauh dari kota, namun di beberapa tempat yang tidak terdapat akses ke jaringan listrik PLN, genset menjadi penyedia utama atau satu-satunya. Misalnya fasilitas menara Base Tranciever Station (BTS), proyek yang berlokasi di tengah hutan dan lainnya. karena peran pentingnya, maka genset harus dipastikan dalam kondisi baik, bahan bakar utama untuk menggerakkan genset harus terencana dengan baik dan komponen-komponen pendukung lainnya dipastikan bekerja dengan baik. Penelitian ini sebuah prototipe yang dapat mengetahui status pasokan daya listrik dari genset, status kapan dan berapa lama genset beroperasi dalam kurun waktu setiap bulan, sehingga dapat diperoleh data prediksi kebutuhan bahan bakar setiap bulan. Hal ini untuk menghindari bahan bakar habis di tengah operasional atau menumpuk di tempat operasi genset. Alat ini juga dilengkapi dengan PZEM 004T untuk mengetahui kualitas listrik yang dihasilkan genset terhadap beban, voltage sensor 0-25 Direct Current (DC) untuk mengetahui tegangan baterai starter genset, dan sensor fuel level magnetic untuk mengetahui ketersediaan bahan bakar yang ada pada tangki. Parameter-parameter di atas diakuisisi menggunakan mikrokontroler dan dikirimkan melalui jaringan Long Range (LoRa) menuju stasiun operasional atau pusat pemantauan terdekat. Sehingga data-data parameter dapat direkam dan dicatat sebagai laporan pemeliharaan dan pengawasan dengan perangkat lunak pendukung Node RED dan database XAMPP.
Pelatihan dan Perakitan Mesin Sanding dengan Penggerak Motor Listrik untuk Operator di PT Rekayasa Unggul Indonesia Eka Samsul Ma'arif; Budiyanto Budiyanto; Prian Gagani Chamdareno; Rohimi Zamzam; Eko Ari Wibowo
Jurnal Pengabdian Masyarakat Kesosi Vol. 8 No. 2 (2025): Juli: Jurnal Abdimas KESOSI
Publisher : Sekolah Tinggi Ilmu Kesehatan Kesetiakawanan Sosial Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.57213/abdimas.v8i2.337

Abstract

The demand for motor vehicle components continues to increase in line with the development of the automotive industry and high customer demand. This condition requires manufacturers to make various innovations in increasing production capacity, speeding up processes, and reducing defect values (Not Good) in order to remain competitive in the market. One of the important processes in making components is sanding, which is the stage of smoothing the surface using sandpaper, both by manual and machine methods. The manual sanding process has several limitations, including varying accuracy of results, relatively slow processing speed, and a higher risk of work accidents. Therefore, more efficient, safe, and consistent technology is needed in producing optimal product quality. In order to answer these challenges, PT. Reingeniería Unggul Indonesia held a training program as well as the assembly of sanding machines with electric motor drives. The result of this activity is in the form of one sanding machine unit with a production capacity of 250 pcs per shift, with the lowest defect rate of only 2.6%. The machine is designed to improve work efficiency, reduce reliance on manual processes, and provide more precise smoothing results. The success of this program not only improves the quality of production, but also contributes to the improvement of employees' technical skills in operating modern machines. With this innovation, the company can meet the increasingly high market demand, while maintaining consistent product quality. In the future, this electric motor-based sanding machine is expected to be a sustainable solution for the automotive component industry that prioritizes speed, quality, and work safety.