Claim Missing Document
Check
Articles

Found 18 Documents
Search

IMPLEMENTASI SOLAR TRACKER PADA PLTS OFF GRID UNTUK SISTEM PENDETEKSI BANJIR Faturrachman, Luthfi; Rozak, Ojak Abdul; Multi, Abdul; Samiaji, Ghani
Electro Luceat Vol 10 No 2 (2024): Elektro Luceat- November 2024
Publisher : LPPM Poltek ST Paul

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32531/jelekn.v10i2.822

Abstract

Solar energy is an inexhaustible renewable energy resource. This can also be used as energy that can be converted into electricity. Due to the importance of using electrical energy, electricity network management companies in Indonesia continue to experience price per kwh increases in proportion to the increasing amount of electrical energy consumption. Therefore, alternative energy is needed which functions as an energy generator. On this basis, the author tries to design a power plant using solar power. This test uses two methods, before using the solar tracker and after using the solar tracker. The results of calculating the average power value for ten days of testing before using the solar tracker were 44.3 watts, and the results of calculating the average power value for ten days of testing after using the solar tracker were 53.1 watts. The results of comparing the average power value before and after the implementation of the solar tracker showed an increase in power value of 8.8 watts. The off-grid solar system is able to meet the needs of the system load. The implementation of the use of solar trackers on solar panels is able to increase the value of the generated power.
ANALISIS PERBANDINGAN KUALITAS DAYA LISTRIK BERDASARKAN HARMONISA PADA MOTOR LISTRIK DENGAN SUPLAI TENAGA SURYA DAN PLN Samiaji, Ghani; Multi, Abdul; Rozak, Ojak Abdul; Faturrachman, Luthfi
Jurnal Informatika dan Teknik Elektro Terapan Vol 12, No 3 (2024)
Publisher : Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/jitet.v12i3.4876

Abstract

PLTS off-grid adalah pembangkit listrik yang tidak terhubung ke jaringan dan menggunakan media penyimpanan seperti baterai untuk menyimpan daya pada malam hari atau pada saat intensitas matahari berkurang serta pada saat listrik padam dari PLN.  Penelitian ini membahas tentang THD pada beban motor listrik dengan sumber yang digunakan untuk melakukan pengukuran serta analisis plts off-grid dan sumber pln, setelah itu, dilakukan perbandingan pada harmonisa arus dan tegangan, lalu kemudian disimulasikan menggunakan software ETAP 12.6. Hasil penelitian dan analisis nilai harmonisa dengan mengambil nilai rata-rata THDv dan THDi pada motor listrik 1 fasa, lalu dilakukan perbandingan dengan standard yang berlaku yaitu Standard Institute of Electrical and Electronic Engineers (IEEE) 519: 2014). Kemudian dihitung menggunakan persamaan. Hasil analisis menunjukkan nilai THDv pada motor listrik yang bersumber dari PLN dan PLTS sebesar 2,3 % yang berarti masih dalam batas standar dan hasil deviasi sebesar 0%. Sedangkan nilai THDi pada motor listrik yang bersumber dari PLN sebesar 7,7 % serta sumber dari PLTS sebesar 7,2 % yang berarti dari kedua pengukuran masih dalam batas standar IEEE dan terjadi perbandingan pengukuran THDi tersebut dengan nilai sebesar 6,4 %. Nilai perbandingan tersebut dapat mempengaruhi kualitas daya listrik
Increasing the Reliability of Distribution Systems By Utilizing Mobile Transformer Units Multi, Abdul; Cahyadi, Muhammad Rijal
International Journal of Advanced Multidisciplinary Vol. 4 No. 1 (2025): International Journal of Advanced Multidisciplinary (April-June 2025)
Publisher : Green Publisher

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.38035/ijam.v4i1.804

Abstract

Maintenance of electrical installations continues to be carried out in maintaining reliability of continuity of electricity distribution. Distribution transformer maintenance activities are carried out in a state without voltage. Of course, with condition without voltage, it has an impact on power outages which can reduce reliability value of the distribution system. In 2024, PT PLN (Persero) UP3 Cempaka Putih has carried out transformer maintenance activities at 7 distribution substations with an average outage duration is 155 minutes. At Distributon Substation TP117, transformer maintenance has been carried out using a minimal outage method, namely by utilizing Mobile Transformer Units as mediator for temporary load transfer during maintenance. Total duration of the outage was only 44 minutes with value of SAIDI is 0.035 minutes/customer and value of ENS is 245,084.07 Wh. By calculating the SAIDI and ENS values based on the pure duration of maintenance work, SAIDI value is calculated to be greater, amount 0.102 minutes/customer and the ENS value is 708,515.77 Wh. So it can be determined that the potential reduction for SAIDI value is 65.69% and ENS value is 65.41%. This means that the reliability of the distribution system can increase because the SAIDI and ENS values can be reduced.
Plasma Generator Design For Citarum River Water Purification and Sterilization After Initial Filterization Multi, Abdul; Purnomo, Agung Sigit; Wahyuningsih, Eko Sri
International Journal of Advanced Multidisciplinary Vol. 4 No. 1 (2025): International Journal of Advanced Multidisciplinary (April-June 2025)
Publisher : Green Publisher

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.38035/ijam.v4i1.960

Abstract

Mountain water is the main raw material in drinking water depots and water from drinking water companies is known as healthy water and good for consumption, people think this water is the best, while the population, costs increase every year, and transportation terrain is increasingly difficult, how long can this condition last. River water and soil that are properly processed, namely filtration and ozone disinfection, can be a substitute for mountain water, by designing, creating, and implementing appropriate technology to process river water and soil so that it is suitable for consumption. Plasma Generator is a tool for producing Ozone, which is used as a strong disinfectant and without residue in water. This tool uses a spiral cylinder electrode method with Dielectric Barrier Discharge (DBD). Corona release occurs between high voltage electrodes of 13.28 kV from a distance between electrodes of 0.5 mm, capable of producing ozone that can purify dirty water and sterilize water containing E. coli bacteria.
IMPLEMENTASI SOLAR TRACKER PADA PLTS OFF GRID UNTUK SISTEM PENDETEKSI BANJIR Faturrachman, Luthfi; Rozak, Ojak Abdul; Multi, Abdul; Samiaji, Ghani
Electro Luceat Vol 10 No 2 (2024): Elektro Luceat- November 2024
Publisher : LPPM Poltek ST Paul

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32531/jelekn.v10i2.822

Abstract

Solar energy is an inexhaustible renewable energy resource. This can also be used as energy that can be converted into electricity. Due to the importance of using electrical energy, electricity network management companies in Indonesia continue to experience price per kwh increases in proportion to the increasing amount of electrical energy consumption. Therefore, alternative energy is needed which functions as an energy generator. On this basis, the author tries to design a power plant using solar power. This test uses two methods, before using the solar tracker and after using the solar tracker. The results of calculating the average power value for ten days of testing before using the solar tracker were 44.3 watts, and the results of calculating the average power value for ten days of testing after using the solar tracker were 53.1 watts. The results of comparing the average power value before and after the implementation of the solar tracker showed an increase in power value of 8.8 watts. The off-grid solar system is able to meet the needs of the system load. The implementation of the use of solar trackers on solar panels is able to increase the value of the generated power.
ANALISIS PERBANDINGAN KUALITAS DAYA LISTRIK BERDASARKAN HARMONISA PADA MOTOR LISTRIK DENGAN SUPLAI TENAGA SURYA DAN PLN Samiaji, Ghani; Multi, Abdul; Rozak, Ojak Abdul; Faturrachman, Luthfi
Jurnal Informatika dan Teknik Elektro Terapan Vol. 12 No. 3 (2024)
Publisher : Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/jitet.v12i3.4876

Abstract

PLTS off-grid adalah pembangkit listrik yang tidak terhubung ke jaringan dan menggunakan media penyimpanan seperti baterai untuk menyimpan daya pada malam hari atau pada saat intensitas matahari berkurang serta pada saat listrik padam dari PLN.  Penelitian ini membahas tentang THD pada beban motor listrik dengan sumber yang digunakan untuk melakukan pengukuran serta analisis plts off-grid dan sumber pln, setelah itu, dilakukan perbandingan pada harmonisa arus dan tegangan, lalu kemudian disimulasikan menggunakan software ETAP 12.6. Hasil penelitian dan analisis nilai harmonisa dengan mengambil nilai rata-rata THDv dan THDi pada motor listrik 1 fasa, lalu dilakukan perbandingan dengan standard yang berlaku yaitu Standard Institute of Electrical and Electronic Engineers (IEEE) 519: 2014). Kemudian dihitung menggunakan persamaan. Hasil analisis menunjukkan nilai THDv pada motor listrik yang bersumber dari PLN dan PLTS sebesar 2,3 % yang berarti masih dalam batas standar dan hasil deviasi sebesar 0%. Sedangkan nilai THDi pada motor listrik yang bersumber dari PLN sebesar 7,7 % serta sumber dari PLTS sebesar 7,2 % yang berarti dari kedua pengukuran masih dalam batas standar IEEE dan terjadi perbandingan pengukuran THDi tersebut dengan nilai sebesar 6,4 %. Nilai perbandingan tersebut dapat mempengaruhi kualitas daya listrik
Desain Ulang Implementasi Jaringan Fiber To The Home (FTTH) Berbasis GPON Untuk Meningkatkan Kepuasan Pelanggan Resdinanto, Resdinanto; Multi, Abdul; Harfi, Razul; Supriadi, Eddy
Proceeding Mercu Buana Conference on Industrial Engineering Vol 4 (2022): RENEWABLE ENERGY TOWARD SUSTAINABILITY OF SUPPLY CHAINS IN THE I4.0 ERA
Publisher : Universitas Mercu Buana

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22441/MBCIE.2022.009

Abstract

Industri Telekomunikasi GPON di Indonesia berkembang sangat pesat, ditandai oleh persaingan yang ketat antara penyedia layanan paket internet, yang membuat setiap pelaku bisnis di industri telekomunikasi GPON berusaha mempertahankan pelanggannya dan menjangkau pelanggan baru untuk memastikan kelangsungan hidup perusahaan. Penelitian ini bertujuan untuk mengetahui pengaruh kualitas pelayanan, harga paket, kualitas produk terhadap kepuasan dan loyalitas pelanggan, yang kemudian mengetahui pengaruh kepuasan pelanggan terhadap loyalitas pelanggan terhadap paket internet tricara. Pengumpulan data dilakukan dengan membagikan 100 (seratus) kuesioner di wilayah Kota Baru Parahyangan Bandung. Data yang diperoleh diproses melalui pemodelan Structural Equation Modeling (SEM) dengan aplikasi SmartPLS  dengan hasil bahwa yang berpengaruh  positif dan tidak singnifikan adalah variabel Kualitas pelayanan teradap  teradap kepuasan pelanggan, kualitas pelayanan teradap loyalitas pelanggan,  variabel kualitas produk teradap kepuasan pelanggan,   harga paket teradap loyalitas pelanggan sedangkan  variabel yang perpengaruh positif dan signifikan adalah harga paket teradap kepuasan pelanggan, kualitas pelanggan teradap loyalitas pelanggan, kualitas produk teradap loyalitas pelanggan. Sedangkan hasil smartpls dari outer weight dan besar pengaruh kualitas pelayanan, harga paket dan kualitas produk teradap loyalitas pelanggan sebesar 0,607 atau 60,7% dan besarnya pengaruh kualitas pelayanan, harga paket dan kualitas produk teradap kepuasan pelanggan sebesar 0,557 atau 55,7%. sehingga didapat nilai Q-Square sebesar 0,826 Hal ini menunjukkan besarnya keragaman dari data penelitian yang dapat dijelaskan oleh model penelitian adalah sebesar 82,6%, sedangkan sisanya 17,4% dijelaskan oleh factor lain yang berada diluar model penelitian ini. Dengan demikian, dari hasil tersebut maka model penelitian ini dapat dinyatakan telah memiliki goodness of Fit yang baik. Dan desain ulang implementasi FTTH untuk meningkatkan performance teradap kualitas pelayanan dan kualitas produk berbasis GPON
Peningkatan Kualitas Proses Pekerjaan untuk Mengurangi Penyebab Cacat Produk pada Produksi Crankcase Sepeda Motor Automatic pada PT. XYZ Bhirawa, Waspada Tedja; Supriadi, Eddy; Multi, Abdul; Harfi, Razul
Proceeding Mercu Buana Conference on Industrial Engineering Vol 4 (2022): RENEWABLE ENERGY TOWARD SUSTAINABILITY OF SUPPLY CHAINS IN THE I4.0 ERA
Publisher : Universitas Mercu Buana

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22441/MBCIE.2022.017

Abstract

Sepeda Motor Automatic pada PT XYZ, dengan menggunakan metode seven tools dan six sigma.Seven tools dan six sigma sebagai salah satu alternatif dalam prinsip-prinsip pengendalian kualitas, dengan metode six sigma memungkinkan perusahaan melakukan peningkatan luar biasa dengan terobosan yang aktual. Berdasarkan diagram pareto, ditemukan penyebab kecatatan ada 5, yaitu gompal, misrun, reta, blister dan flowline. Cacat yang paling besar yaitu gompal  dengan persentase dari total kecacatan adalah 78%. Penyebab lainnya yaitu misrun, blister, retak dan flowline dengan persentase masing-masing 4%, 3%, 2%,5% dan 2%. Penyebab Utama adalah faktor manusia, perbaikan yang dilakukan adalah, supervisor mengawasi secara berkala pekerjaan operator untuk pemotongan sprue dan gate, juga dilakukan penyegaran pelatihan kembali. Setelah dilakukan perbaikan, tingkat cacat pada produk crankcase sebelum dan sesudah perbaikan pada dasarnya berbeda. Jumlah kerugian pada bulan Januari 2020 COPQ   = Rp 94.860.000,- dan Februari  2020 COPQ   = Rp 99.165.000,- setelah diadakan perbaikan dengan menggunakan seven tools  kerugian dapat diturunkan. Jumlah kerugian pada bulan Maret 2020 COPQ   = Rp 37.275.000,-.       Upaya Perbaikan dari penyebab utama faktor manusia adalah dengan menempatkan supervisor mengawasi secara berkala pekerjaan operator untuk pemotongan sprue dan gate, juga dilakukan penyegaran pelatihan kembali. Pada saat terjadi overtime atau lembur, harus dipastikan untuk para pekerja mendapatkan pengawasan yang cukup ketat, mengingat akan terjadi kelelahan dan ini akan mengakibatkan ketidak telitian dalam bekerja. Dan memastikan peralatan yang digunakan masih berfungsi dengan baik, misalnya palu dan pemotong sprue dari hasil cetakan.