Perencanaan Heater Pada Proses Pembuatan Seng Di PT. KALIMANTAN STEEL CO. LTD .,, Fuazen
ELKHA : Jurnal Teknik Elektro Vol 5, No 2 (2013): Edisi Bulan Oktober 2013
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (240.163 KB) | DOI: 10.26418/elkha.v5i2.5032

Abstract

Abstract One type of heat exchanger used is the type of heat exchanger Shell and Tube. Feasibility of making use of a heat exchanger is heating fluid and the fluid is heated, how much economic value is obtained. From these data, the process of making zinc plate in the PT. Kalimantan Steel CO. LTD uses diesel as fuel for heating water H2SO4 + 1.5% with an average in the 30 liter to 2000 sheets of tin plate. Through the concept of the Energy Management Program (PME) heat exchanger made ??by utilizing the residual heat of backling as a substitute for diesel fuel. Keywords- Heat exchangers, shell and tube, the Energy Management Program (PME)
Analisis Tingkat Efisiensi pada Sistem Pengkondisian Udara Gedung Auditorium di Universitas Muhammadiyah Pontianak Riski Nurhalim; Gunarto Gunarto; Eko Sarwono; Fuazen Fuazen
Creative Research in Engineering Vol 1, No 1 (2021): Creative Research in Engineering (CERIE)
Publisher : Lembaga Publikasi Ilmiah dan Penerbitan (LPIP)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (219.508 KB) | DOI: 10.30595/cerie.v1i1.9215

Abstract

Mengamati berbagai acara seperti sudut sinar matahari, pengukuran suhu dinding luar, berbagai aksesoris yang tersedia dan jenis kegiatan yang dilakukan. Kemudian dilakukan perhitungan dengan metode CLTD (Cooling Load Temperature Difference) berdasarkan ASHRAE 1997. Hasil yang diperoleh adalah beban pendinginan dari seperti dinding bata dengan lapisan plester, kaca, atap aluminium alloy, lantai beton dan keramik, lampu, penghuni, peralatan elektronik . dan jumlah maksimal 1.500 orang di Gedung Auditorium Muhammadiyah Pontianak adalah 349.772.358 Watt atau 132,60 PK. AC yang terpasang saat ini berkapasitas 40 PK, sehingga dibutuhkan 92,6 PK PK lebih atau 19 unit alat pendingin yang masing-masing berkapasitas 5 PK agar pendinginan di dalam ruangan lebih hemat. 
Analisa Uji Kekerasan Roda Gigi Lurus Dengan Sistem Rapid Prototyping Fuse Deposition Modeling Eko Julianto; Dimas Saputra; Fuazen Fuazen; Eko Sarwono
Creative Research in Engineering Vol 2, No 1 (2022): Creative Research in Engineering (CERIE)
Publisher : Lembaga Publikasi Ilmiah dan Penerbitan (LPIP)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30595/cerie.v2i1.14061

Abstract

Penelitian ini mengetahui nilai kekerasan bahan PLA (Polylactic Acid) berdasarkan variasi parameter cetak printer 3D dengan suhu 200 °C dan 220 °C serta tinggi lapisan 0,1 mm dan 0,2 mm sebagai dasar perancangan roda lurus. Proses kekerasan yang dilakukan menggunakan hardness rockwell tester kemudian dilakukan perbandingan dari perhitungan kekerasan berdasarkan indentasi hasil pengujian pengujian rockwell. Standar uji yang digunakan ISO 2039-2 : 2000. Pengumpulan data dilakukan secara kuantitatif berdasarakan studi literatur, observasi dan konsulstasi. Hasil pengujian Analisis secara statistik menggunakan ANOVA dua arah. Dari pengujian ini didapatkan nilai kekerasanterbaik yang ada pada parameter temperature 220C dan tinggi lapisan 0,1 mm.
Analisa Uji Kekerasan Roda Gigi Lurus Dengan Sistem Rapid Prototyping Fuse Deposition Modeling Eko Julianto; Dimas Saputra; Fuazen Fuazen; Eko Sarwono
Creative Research in Engineering Vol 2, No 1 (2022): Creative Research in Engineering (CERIE)
Publisher : Lembaga Publikasi Ilmiah dan Penerbitan (LPIP)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30595/cerie.v2i1.13208

Abstract

Tujuan penelitian ini yaitu mengetahui nilai kekerasan bahan PLA (Polylactic Acid) berdasarkan variasi parameter cetak printer 3D dengan suhu 200 °C dan 220 °C serta tinggi lapisan 0,1 mm dan 0,2 mm sebagai dasar perancangan roda lurus. Proses pengujian kekerasan dilakukan menggunakan hardness rockwell tester kemudian dilakukan perbandingan dari perhitungan kekerasan berdasarkan indentasi hasil pengujian rockwell. Standar uji yang digunakan ISO 2039-2 : 2000. Teknik pengumpulan data dilakukan secara kuantitatif berdasarkan studi literatur, observasi dan konsultasi. Hasil Pengujian Analisis secara statistik menggunakan ANOVA dua arah. Dari pengujian ini didapatkan nilai kekerasan terbaik ada pada parameter temperature 220C dan tinggi lapisan 0,1 mm.
Studi Komparatif Efektivitas Perpindahan Kalor dengan Pengaturan Laju Aliran Fluida Pendingin Heat Exchanger Jenis Plate Aliran Searah Joni Rahmadi; Fuazen Fuazen; M. Jusri Suganda Putra
Jurnal Pendidikan Tambusai Vol. 7 No. 1 (2023): April 2023
Publisher : LPPM Universitas Pahlawan Tuanku Tambusai, Riau, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (391.106 KB)

Abstract

Pada penelitian ini akan melakukan eksperimen untuk melihat pengaruh laju aliran terhadap efektivitas perpindahan panas pada penukar kalor aliran searah jenis plate. Dalam penelitian ini, penulis akan melihat pengaruh variasi laju aliran air pendingin terhadap efektifitas perpindahan panas pada penukar kalor jenis Plate aliran searah dengan mempertahankan laju aliran fluida yang didinginkan (fluida panas). Variasi laju aliran massa untuk aliran air pendingin adalah 50 gr/sec, 40 gr/sec dan 30 gr/sec. Sedangkan untuk laju aliran air panasnya dipertahankan tetap untuk setiap variasi laju aliran air pendingin yaitu 50 gr/sec. Penelitian ini bertujuan untuk mengetahui pada laju aliran berapa fluida pendingin yang paling optimal perpindahan panasnya pada aliran searah dengan harapan untuk menjadi sebuah rekomendasi untuk penyetingan laju aliran fluida untuk mendapatkan efektifitas perpindahan panas pada penukar kalor jenis Plate yang aliran fluidanya searah. Dari hasil penelitian didapatkan efektivitas penukar kalor jenis Plate Heat Exchanger aliran searah nilai efektivitas penukar kalor yang paling besar adalah pada laju aliran massa sebesar 50 gr/sec. Sedangkan kenaikan efektivitas penukar kalor pada Plate Heat Exchanger aliran searah berada pada laju aliran massa 40 gr/sec. Dalam penelitian ini menunjukan bahwa ada nilai optimum laju aliran massa tertentu yang bisa menyebabkan kenaikan efektivitas penukar kalor sangat tajam.
Comparative Study of Heat Transfer Rate in Solar Water Heater by Varying the Sun Incoming Angle and Flow Rate of Sun Heat Absorpting Fluid Joni Rahmadi; Fuazen; Indra Lukman
International Journal of Integrative Sciences Vol. 2 No. 3 (2023): March 2023
Publisher : PT FORMOSA CENDEKIA GLOBAL

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55927/ijis.v1i4.3378

Abstract

The issue of Green Energy, which is about clean and environmentally friendly energy, is a very important issue at this time. Energy that has the above properties is renewable energy. Optimization of energy absorption needs to be done and this is usually done by conditioning or manipulating several parameters so that the energy absorption rate is more effective and efficient.Therefore, the authors conducted a study that is expected to know at the angle of arrival and the rate of flow what is the most optimal absorption of heat from solar energy for the installation and seeding of Solar Water Heater in Pontianak City. And it is expected that with this research can be a recommendation of energy absorption rate, especially those who use solar energy for the Pontianak City area of West Kalimantan to be optimal and efficient.Based on the results of research and analysis conducted in this study for the setting of the sun's coming angle of 450 and coolant fluid flow rate setting, namely the Solar Collector Loop side of 1250 ccm and on the Domestic Heater Water Loop of 1000 ccm in solar water heater. The setting of angles and flow rate settings in the conditions mentioned are very suitable for the condition of Pontianak city area which provides a very stable efficiency value and the value is close to 100% and the value of heat transfer is quite optimal both the absorption of solar heat and heat absorption by heated water
Damage Analysis of Leaf Springs Dump Truck Hino Dutro 130 HD Joni Rahmadi; Fuazen; Adani AS
International Journal of Integrative Sciences Vol. 2 No. 3 (2023): March 2023
Publisher : PT FORMOSA CENDEKIA GLOBAL

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55927/ijis.v1i4.3536

Abstract

Leaf springs that have been used for a long time will experience a decrease in the quality of the mechanical properties due to the dynamic loads that occur on this component. A comparison of two leaf spring materials is carried out, this is expected to be a solution to increase the strength and toughness of the leaf springs that have been used, the strength and carrying capacity of the damp truck is 8 tons. Spring damage mechanical strength Tensile Strength of Indospring Materials. In a Hino Dutro 130 HD brand car. The average tensile stress is 44.8 (HRC) The average tensile stress is 1407.8 N/mm2 The hardness in specimen 1 is 1407 N/mm2 in specimen 2, the hardness is 1408 N/mm2 in specimen 3, the result is hardness 1409 N/mm2 on specimen 4 with a hardness of 1407 N/mm2 and on specimen 5 the force value of hardness is 1408 N/mm2 Bending test of Indospring Material that has been carried out on Bending test data of Indospring Material to analyze the mechanical strength of spring damage. Strength of Indospring Material. In a Hino Dutro 130 HD brand car. Tensile force Hardness average 1407.8 N/mm2 HOP Material Bend, Indospring. In a Hino Dutro 130 HD brand car. The average hardness force is 1407.8 N/mm2. So that the strength of this material is feasible and good for use while loading trucks. Which is flat paved, so the weight of the cargo transported is not known with certainty. However, it can be estimated based on the carrying capacity, the weight of the cargo ranges from 7-10 tons, for one transport
Pengaruh Perendaman Air Laut Terhadap Sifat Mekanik pada Hasil Pengelasan Plat St 37 pada Lambung Kn. Ae-012 Distrik Navigasi Kelas Iii Pontianak Joni Rahmadi; Fuazen; Eko Julianto; Hasanudin
Syntax Literate Jurnal Ilmiah Indonesia
Publisher : Syntax Corporation

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36418/syntax-literate.v8i8.13252

Abstract

In the current era of industrialization, welding techniques have been widely used, covering the work of shipping, bridges, steel frames, pipelines and so on, although this is not the main objective, it is a means to achieve a better manufacturing process. so you have to really pay attention to the suitability between the properties of the welding itself, namely the strength of the connection and pay attention to the connection to be welded, so that the results of the welding are as expected. Welding applications include shipyard construction in the framework of making bodies and other parts, so it is necessary to pay attention to the relationship to the corrosion rate that occurs at welding joints. Seawater intrusion on steel construction corrodes the structure due to the content of chloride and sulfate ions in seawater which react to the chemical elements of the steel. So that the corrosion rate that occurs greatly affects the mechanical properties of the ST 37 plate welding results on the KN hull. AE-012 Pontianak Class III Navigation District, on tensile strength and bending strength in the workpiece, HAZ area, and base metal. Testing the strength of the welding joints with Electric Arc Welding using a current strength of 120 Amperes on mild steel material (ST 37) against the effect of salt water immersion for 20 days, 35 days and 50 days the following values are obtained: [i] At 20 days of immersion time the value the tensile strength is 202.08 N/mm2 , 35 days the tensile strength value is 215.42 N/mm2 and 50 days the tensile strength value is 221.46 N/mm2 , [ii] For the tensile strength values at immersion of 35 days and 50 days has a value that tends to increase, this is somewhat different from the value of the tensile strength at 20 days immersion time which tends to decrease the value of the tensile strength without immersion. The effect of salt water immersion on the value of bending strength in mild steel (ST 37), it was found that: [i] At 20 days of immersion the bending strength value was 1500 N/mm2, 35 days the bending strength value was 1845 N/mm2 and 50 days the bending strength value was the bending strength is 1460 N/mm2 , [ii] The bending strength value at 35 days immersion has a value that tends to increase closer to the bending strength value without immersion, this is somewhat different from the bending strength value at 50 days immersion which tends to decrease considerably at compare without immersion.
Analisa Pemanfaatan Energi Terbuang (Wasted Energy) pada Perencanaan Heater di PT Samudera Windu Cold Storage Erlangga Atidhira Hadijaya; Fuazen; Joni Rahmadi
Syntax Literate Jurnal Ilmiah Indonesia
Publisher : Syntax Corporation

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36418/syntax-literate.v8i8.13420

Abstract

One type of heat exchanger that is widely used is the shell and tube type heat exchanger. The feasibility of making this heat exchanger is seen from the use of heating fluid and heated fluid, how much economic value is obtained. From the data obtained, that in the process of making ice cubes using cold storage which is in the cooling process in the condenser using river water and has a high enough temperature, so that it can be used as a heating source. Through the concept of the Energy Management Program (PME) a heat exchanger with utilizing residual heat as a preheater for the use of water consumption for bathing, washing, and so on.
ANALISA PENGARUH KONDISI TEMPERATUR YANG BERBEDA TERHADAP WATER CONTENT PADA SAAT PENERIMAAN MARINE FUEL OIL (MFO) DI PLTD SIANTAN Muhamad Irfan; Fuazen Fuazen; Eko Sarwono
Suara Teknik : Jurnal Ilmiah Vol 10, No 2 (2019): Suara Teknik: Jurnal Ilmiah
Publisher : Fakultas Teknik UM Pontianak

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29406/stek.v10i2.1543

Abstract

Marine Fuel Oil (MFO) adalah bahan bakar minyak, yang digunakan untuk pembakaran langsung di dapur - dapur industri dan pemakaian lainnya. MFO merupakan bahan bakar minyak yang bukan termasuk jenis distilate, tetapi termasuk jenis residu yang lebih kental pada suhu kamar serta berwarna hitam pekat. Pada penelitian ini, pengujian nilai water content pada kondisi temperatur yang berbeda pada tiap – tiap penerimaan MFO untuk memenuhi persyaratan dan layak untuk dapat digunakan sebagai bahan bakar mesin diesel di PLTD Siantan. Penelitian ini bertujuan untuk mengetahui inilah water content pada kondisi temperatur yang berbeda sehingga didapat batas nilai yang sesuai dengan standar ASTM D-95 dan mengetahui nilai water content berdasarkan grafik. Penelitian ini menggunakan metode studi eksperimental yaitu metode lapangan (field research) yang dilakukan pengujian langsung dengan cara membandingkan antara MFO saat temperatur tinggi dan MFO saat temperatur rendah dengan menggunakan alat uji water content dalam satu periode di PLTD Siantan. Pengujiannya meliputi nilai kondisi temperatur dan nilai sampel water content MFO saat penerimaan dengan membandingkan hasil yang didapat dari PT Pertamina, Sucofindo dan Peneliti. Dan didapat hasil berdasarkan pengujian dengan nilai water content terendah sebesar 0,02% pada temperatur 35 °C dan nilai water content tertinggi sebesar 0,11% pada temperatur 31 °C. Semua pengujian sampel MFO sudah memenuhi standar ASTM D-95.