Claim Missing Document
Check
Articles

Found 22 Documents
Search

Performance Evaluation of an Rfid-Based Fire Safety Equipment Identification System Integrated with The Izat Digital Platform: A Case Study at a Thermal Power Plant Dwi Ajiatmo; Fifin Azimatul Warisah; Hidayatul Nurohmah; Syarofan Zulfahmi
PROCEEDING ICTESS (Internasional Conference on Technology, Education and Social Sciences) Vol 8 (2026): ICTESS 8th
Publisher : Universitas Slamet Riyadi Surakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Routine inspection of fire safety equipment is a core element of occupational health and safety (OHS) management in power generation facilities, yet paper-based inspection is slow, prone to identification and recording errors, and difficult to trace. This case study evaluates an RFID-based equipment identification system, already in operation and integrated with the iZat (Zero Accident Assistant) digital inspection platform, at PT PLN Nusantara Power UP Tanjung Awar-Awar, Tuban, Indonesia. Between April and July 2025, data were collected on the inspection of 778 equipment units (440 portable fire extinguishers, 323 hydrant boxes with accessories, and 15 first-aid boxes) through direct observation, structured interviews with 25 respondents, and document review. Manual and RFID–iZat inspection were compared descriptively using a non-concurrent before–after design. Mean inspection time fell from 2.5 to 1.2 minutes per unit, a reduction of 52%. The recording error rate for equipment identity fell from approximately 7% to none in observed records, and the equipment data displayed after a tag scan matched the registered data in all observed scans. Because the comparison is uncontrolled and confined to one site, these figures are observational estimates, and they describe the integrated system rather than RFID alone. Reported constraints were tag loss and damage, areas with weak network coverage, the absence of supervisory validation of submitted reports, and the absence of the previous inspection result on the scan screen. The study contributes an empirical account of an operating RFID-integrated inspection platform in a thermal power plant, a mapping of system functions to the components that provide them, and a record of operational failure modes.
Lighting Installation System Design in the Parking Area of Prof. Dr. Soekandar Mojokerto Regional Hospital Based on Dialux Software: Desain Sistem Instalasi Penerangan pada Area Parkir RSUD Prof Dr Soekandar Mojokerto berbasis Dialux Software Budi Utomo; Dwi Ajiatmo; Hidayatul Nurohmah; Machrus Ali
JEEE-U (Journal of Electrical and Electronic Engineering-UMSIDA) Vol. 10 No. 2 (2026): Oktober
Publisher : Muhammadiyah University, Sidoarjo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21070/jeeeu.v10i1.1744

Abstract

This study aims to design an optimal lighting installation system for the parking area of RSUD Prof. Dr. Soekandar Mojokerto by using DIALux Evo as a lighting simulation tool. The existing lighting system employs three 150 W High Pressure Sodium (HPS) lamps and does not meet the parking area lighting standard specified in SNI 7391:2008. The simulation results of the existing condition indicate an average illuminance of 35.3 lux, an average luminance of 3.37 cd/m², a uniformity ratio of 0.005, and a Unified Glare Rating (UGR) of 25. To improve the lighting performance, a redesign was carried out using 17 units of 57 W LED lamps. The simulation results of the proposed design show significant improvement, with an average illuminance of 96.5 lux, an average luminance of 9.21 cd/m², a uniformity ratio of 0.37, and a glare level of 19. Although the energy consumption increased from 5.4 kWh to 11.628 kWh, this increase is proportional to the improvement in lighting quality. The results indicate that the use of LED lamps provides brighter, more uniform, and more visually comfortable lighting while complying with the applicable standards. Therefore, the DIALux Evo-based lighting design is recommended for implementation in hospital parking areas and similar public facilities.