Claim Missing Document
Check
Articles

Found 2 Documents
Search
Journal : Infotekmesin

Rancang Bangun Monitoring Early Warning System Bencana Banjir Berdasarkan Ketinggian Aliran Sungai Mengunakan Modem SIM900 dan Internet of Things Arif Sumardiono; Erna Alimudin; Zaenurrohman; Hera Susanti
Infotekmesin Vol 13 No 1 (2022): Infotekmesin: Januari, 2022
Publisher : P3M Politeknik Negeri Cilacap

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35970/infotekmesin.v13i1.1019

Abstract

The rainfall in the Cilacap region is high, about 80-100mm in October-March. The high rainfall that causes the overflow of river water is unpredictable. The high water discharge is not realized until the river water overflows and causes flooding. Therefore, a river water level monitoring system is needed to detect river overflows early. This tool uses a solar cell as a power supply. The monitoring system is divided into two points of river water level monitoring system with a distance between points for the laboratory scale stage, which is 100 meters. Sensors that measure the height of river flow are ultrasonic sensors. The sensor results are processed by microcontroller and SIM 900 L module to be sent to the database. When the water level is in the Alert level 3, the buzzer will sound as a warning. The ultrasonic sensor test results have a very small error. Sensor 1 has an average error of 0.00023% and ultrasonic sensor 2 has an error of 0.00016%. The system is able to transmit river water level data that can be accessed through the website.
Analisa Terjadinya Electrical Treeing Pada Isolator Komposit dengan Bahan Pengisi Serat Pelepah Nipah Saepul Rahmat; Riyani Prima Dewi; Erna Alimudin
Infotekmesin Vol 15 No 1 (2024): Infotekmesin: Januari, 2024
Publisher : P3M Politeknik Negeri Cilacap

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35970/infotekmesin.v15i1.2090

Abstract

Technological developments in materials are increasingly evolving, one form of development is the type of composite insulation. One of the natural fiber composites currently available is a composite from palm fiber which provides increased dielectric strength. Partial discharge due to voids in the composite results in structures such as electrical treeing due to changes in the properties and morphology of the composite causing increased insulation failure and disrupting power distribution. This research tested the strength of Epoxy composite insulation and palm leaf ash filler. By combining these two materials, a complementary composite insulating material will be formed to prevent electrical treeing. The results of the research show that the composite insulating material with nipa palm fiber as filler has an average breakdown voltage value of 40 kV and is above the standard breakdown voltage value for medium voltage insulators of 30 kV. The addition of more and more palm leaf ash filling material will produce voids, thereby accelerating the occurrence of electrical treeing and decreasing the breakdown voltage of the insulation.