Uji Kesesuaian Berkas Cahaya Kolimasi pada Pesawat Sinar-X di Politeknik Al-Islam Bandung Oktarina - Damayanti; Indra - Gunawan
Jurnal Imejing Diagnostik (JImeD) Vol 7, No 2: JULY 2021
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v7i2.6596

Abstract

Background : Suitability test for light collimation are tests to ensure that x-ray aircraft meet radiation safety requirements and provide precise and accurate diagnostic or diagnostic information. Suitability test for light collimation is carried out on x-ray aircraft at Al-Islam Bandung Politeknik.Methods: The research method used in quantitative experimental method. The suitability test was carried out with a collimator test tool and beam alignment test tool placed on the tape then performed an experiment using an exposure factor of 75 Kv, 200 mA and 8 mAs with FFD 100 cm.Results: Based on the tests that have been carried out, it is known that there is a discrepancy in the width of the collimation beam. The large discrepancy between the light field area and the radiation field area, that is, the edge X₁ 0.3 cm, the edge X₂ 0.5 cm, the edge Y₁ 0.5 cm, the edge Y₂ 0.1 cm. So the value of ∆X is 0.8% FFD, the value of ∆Y is 0.6% FFD, and the value of ∆X + ∆Y is 1.4% FFD. While the deviation of the central point is less or right than 3⁰. These results indicate that the discrepancy in the width of the light beam collimation and center point deviations is still within the tolerance limits.Conclusions: There is a discrepancy between the X-ray light field and the collimated light field, but it is still within the limit of the test value to the passing value of the predefined test. 
VARIASI FAKTOR EKSPOSI PADA PEMERIKSAAN SCHEDEL PROYEKSI ANTERIOR POSTERIOR UNTUK HASIL RADIOGRAFI YANG MAKSIMAL DI RUMAH SAKIT AL ISLAM BANDUNG: Variation of Exposure Factors on Schedel Examination using Anterior Posterior Projection to Maximize Radiographs Quality at Al Islam Hospital of Bandung Oktarina Damayanti; Leny A Anggraeni; Surdiyah Asri Ningrum
JURNAL TERAS KESEHATAN Vol 3 No 2 (2020): Jurnal Teras Kesehatan
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat (LPPM) Politeknik Al Islam Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.38215/jutek.v3i1.47

Abstract

The head is an examination that is often done at each hospital, especially Posterior Anterior projection. The quality of the results of a good picture of contrast, density and detail are needed so that the exposure factor will be very influential on the head examination. The study was conducted at Al Islam Hospital in Bandung using the head phantom. Variations in kV and mAs in this study were AP projections with 64 kV and 11.2 mAs, AP schemes with 72 kV and 14.2 mAs, AP heads with 80 kV and 12.6 mAs, AP heads with 88 kV and 14, 2 mAs and AP head radiographs with 96 kV and 16.0 mAs. The maximum exposure factor value on the head phantom in anteroposterior projections based on the data is that the respondent's value has changed and only one is the same or similar from the respondent's perspective, the use of kV 64 and mAs 11.2 has a density value of the ten respondents by 94%, the value of in contrast to the ten respondents by 68%, the sharpness value of the ten respondents by 74%, and the detailed value of the ten respondents by 74%. In the use of kV 72 and mAs 14.2, the density value of the ten respondents was 42%, the contrast value of the ten respondents was 44%, the sharpness value of the ten respondents was 38%, and the retail value of the ten respondents was 38%. The use of kV 80 and mAs 12.6 has a density value of the ten respondents of 56%, the contrast value of the ten respondents by 44%, the sharpness value of the ten respondents by 40%, and the retail value of the ten respondents by 40%. In the use of kV 88 and mAs 14.2, the density value of the ten respondents was 78%, the contrast value of the ten respondents was 64%, the sharpness value of the ten respondents was 64%, and the retail value of the ten respondents was 64%. In the use of kV 96 and mAs 16.0, the density value of the ten respondents was 78%, the contrast value of the ten respondents was 76%, the sharpness value of the ten respondents was 64%, and the retail value of the ten respondents was 80%. According to the evaluation of the ten respondents expose at Al Islam Hospital Bandung, the results of the first radiograph with the exposure factor kV 64 and mAs 11.2 had the highest value. And the lowest index value of each respondent is the exposure factor kV 72 and mAs 14.2.
HASIL UJI KEBOCORAN ALAT PELINDUNG DIRI DENGAN TIGA CARA DI INSTALASI RADIOLOGI RUMAH SAKIT UMUM KARAWANG: THE RESULTS OF PERSONAL PROTECTIVE EQUIPMENT LEAKAGE TEST WITH THREE WAYS IN RADIOLOGY DEPARTMENT, GENERAL HOSPITAL, KARAWANG Oktarina Damayanti
JURNAL TERAS KESEHATAN Vol 4 No 2 (2021): Jurnal Teras Kesehatan
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat (LPPM) Politeknik Al Islam Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.38215/jutek.v4i1.63

Abstract

Radiasi adalah Glombang elektromagnetik dan partikel bermuatan yang karena energi yang dimilikinya sehingga mampu mengionisasi media yang dilaluinya. Radiasi dapat menginduksi kematian sel hingga merusak fungsi jaringan dan organ. Efek ini dapat diamati secara klinis jika dosis paparan radaisi melebihi nilai ambang batas tertentu dan disebut dengan istilah tissue reaction atau yang sebelumnya dikenal dengan efek deterministik Salah satu peralatan proteksi radiasi yang digunakan untuk memberikan perlindungan dari paparan radiasi untuk menjamin keselamatan kerja dari potensial bahaya radiasi pengion adalah apron. Tujuan dari penelitian ini adalah untuk melihat kualitas apron yang ada di Instalasi Radilogi Rumah Sakit Umum Karawang yang secara fisik dianggap sudah tidak layak pakai, dilakukan pengujian agar apron benar – benar dapat melindungi pekerja/ keluarga pasien dari bahaya radias dan dapat dinyatakan aman. Jenis penelitian ini adalah penelitian kuantitaif dengan melakukan tiga cara yaitu dengan uji visualisasi, uji raba dan diuji menggunakan sinar-X pada alat floroscopy,   dan apron yang dilakukan uji kebocoran ada tiga apron dari jumlah apron yang ada di Rumah Sakit. Hasil penelitian didapat   bahwa dengan faktor exsposi sebesar 50 kV, 250 mAs dan 10 mA, dari jumlah apron yang ada di Rumah Sakit Umum Karawang, yang telah dilakukan uji kebocoran yang dianggap layak ada tiga apron,  ketiga apron tersebut secara fisik mengalami kerusakan. Kemudian ketiga apron dilakukan pengujian kebocoran dengan tiga tahapan yaitu uji visualisasi, uji raba dan uji sinar-x maka dinyatakan ketiga apron tersebut mengalami kebocoran radiasi pada Apron No.1, No. 2 dan N0. 3. Apron tersebut dinyatakan tidak layak digunakan sebagai alat proteksi radiasi pada saat melakukan pemeriksaan radiologi baik untuk keluarga pasien ataupun oleh petugas radiologi di Rumah Sakit Umum Karawang karena fisik apron tidak baik dan terdapat patahan yang melebihi kriteria layak digunakan.
Composing Radiographic Dictionary for Radiology Students and Radiographers Euis Reliyanti; Oktarina Damayanti
International Journal of Ethno-Sciences and Education Research Vol 3, No 4 (2023)
Publisher : Research Collaboration Community (RCC)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.46336/ijeer.v3i4.509

Abstract

The rapid development of science and technology on radiology requires radiology students in particular and radiographers in general to be able to understand and master the science and technology through books or scientific articles, which are mostly written in English. To help them understand the radiological scientific information easily, a complete basic terminologies dictionary on radiology is needed. This study aimed to analyze the vocabularies contained in radiology textbooks linguistically which then are compiled into a radiological pocket dictionary. This research used a qualitative descriptive method. Data were taken in the form of vocabulary list resulted from previous research conducted by the author on radiology textbooks in 2019. This research had 7 stages of activities which include syntactic, morphological, semantic, and phonetic analysis. In addition, the vocabularies then went through 2 stages of evaluation to check the perfection of words regarding to their writing, meaning, and pronunciation. Furthermore, each vocabulary was given an example of its use in the form of sentences in the context of radiology. Results of the study in the form of a pocket dictionary consisting list of basic radiological vocabulary/terms accompanied by the syntactic categories, the meaning of words in Indonesian language that are in accordance with the scientific context of radiology, phonetic transcription, and examples of the use of words in sentences in the context of radiology are expected to contribute to improving the quality of human resources of radiographers in Indonesia.
Komparasi Treatment Planning Pada Kanker Leher Rahim Menggunakan Teknik 3DCRT dan IMRT: COMPARISON OF TREATMENT PLANNING IN CERVIX CANCER USING 3DCRT AND IMRT TECHNIQUES suwandi; Damayanti, Oktarina; Ningrum, Surdiyah Asri
JURNAL TERAS KESEHATAN Vol 6 No 1 (2023): Jurnal Teras Kesehatan
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat (LPPM) Politeknik Al Islam Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.38215/jtkes.v6i1.104

Abstract

Cancer is a non-communicable disease that is still a health problem in the world, including Indonesia. About 50 percent of cancer treatments worldwide are performed using radiotherapy. In its implementation, radiotherapy includes several stages, one of which is treatment planning. This study aims to assess the difference in dose received by PTV and OARs in planning using IMRT and 3DCRT techniques in cervical cancer patients. The method used in this study is scanning using a CT simulator, delineating PTV and healthy organs around the tumor (OARs), and planning using treatment planning system software. The results showed that in OARs, 3DCRT planning resulted in a dose of 4000 cGy by hitting 58.28% of the buli volume, and a dose of 5000cGy by hitting 17.76% of the rectum volume. While planning IMRT, a dose of 4000cGy hits 31.50% of the buli volume, and a dose of 5000cGy hits 12.29% of the rectum volume. In PTV, the doses produced by 3DCRT and IMRT planning were 4750cGy and 4750 cGy, and hit 95.18% and 98.71% of PTV volume, respectively. This study concludes that planning using IMRT is better than planning using 3DCRT in cases of cervical cancer. This is shown by the dose that covers the target tumor (PTV) and a significant dose reduction in OARs.    
VARIASI FAKTOR EKSPOSI PADA PEMERIKSAAN SCHEDEL PROYEKSI ANTERIOR POSTERIOR UNTUK HASIL RADIOGRAFI YANG MAKSIMAL DI RUMAH SAKIT AL ISLAM BANDUNG: Variation of Exposure Factors on Schedel Examination using Anterior Posterior Projection to Maximize Radiographs Quality at Al Islam Hospital of Bandung Oktarina Damayanti; Leny A Anggraeni; Surdiyah Asri Ningrum
JURNAL TERAS KESEHATAN Vol 3 No 2 (2020): Jurnal Teras Kesehatan
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat (LPPM) Politeknik Al Islam Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.38215/jutek.v3i1.47

Abstract

The head is an examination that is often done at each hospital, especially Posterior Anterior projection. The quality of the results of a good picture of contrast, density and detail are needed so that the exposure factor will be very influential on the head examination. The study was conducted at Al Islam Hospital in Bandung using the head phantom. Variations in kV and mAs in this study were AP projections with 64 kV and 11.2 mAs, AP schemes with 72 kV and 14.2 mAs, AP heads with 80 kV and 12.6 mAs, AP heads with 88 kV and 14, 2 mAs and AP head radiographs with 96 kV and 16.0 mAs. The maximum exposure factor value on the head phantom in anteroposterior projections based on the data is that the respondent's value has changed and only one is the same or similar from the respondent's perspective, the use of kV 64 and mAs 11.2 has a density value of the ten respondents by 94%, the value of in contrast to the ten respondents by 68%, the sharpness value of the ten respondents by 74%, and the detailed value of the ten respondents by 74%. In the use of kV 72 and mAs 14.2, the density value of the ten respondents was 42%, the contrast value of the ten respondents was 44%, the sharpness value of the ten respondents was 38%, and the retail value of the ten respondents was 38%. The use of kV 80 and mAs 12.6 has a density value of the ten respondents of 56%, the contrast value of the ten respondents by 44%, the sharpness value of the ten respondents by 40%, and the retail value of the ten respondents by 40%. In the use of kV 88 and mAs 14.2, the density value of the ten respondents was 78%, the contrast value of the ten respondents was 64%, the sharpness value of the ten respondents was 64%, and the retail value of the ten respondents was 64%. In the use of kV 96 and mAs 16.0, the density value of the ten respondents was 78%, the contrast value of the ten respondents was 76%, the sharpness value of the ten respondents was 64%, and the retail value of the ten respondents was 80%. According to the evaluation of the ten respondents expose at Al Islam Hospital Bandung, the results of the first radiograph with the exposure factor kV 64 and mAs 11.2 had the highest value. And the lowest index value of each respondent is the exposure factor kV 72 and mAs 14.2.
Planning Posisi Hip Joint Dengan Klinis Osteoporosis Pada Pemeriksaan Dual-Energy X-Ray Absorptiometry Bone Mineral Density Di Instalasi Radiodiagnostik, Imajing Dan Radiologi Intervensi Rumah Sakit Santo Borromeus Bandung Damayanti, Oktarina; Suwandi, Suwandi; Asriningrum, Surdiyah; Novianti Napiun, Bernadetha
Jurnal Cahaya Mandalika ISSN 2721-4796 (online) Vol. 3 No. 3 (2022)
Publisher : Institut Penelitian Dan Pengambangan Mandalika Indonesia (IP2MI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36312/jcm.v3i3.4947

Abstract

Pemeriksaan Dual Energy X-ray Absorptiometri (DXA) Bone Mineral Density (BMD) yang dilakukan di Instalasi Radiodiagnostik, Imajing dan Radiologi Intervensi Rumah Sakit Santo Borromeus Bandung dilakukan salah satunya pada titik hip joint. Pemeriksaan tersebut bertujuan mengkonfirmasi diagnosis osteoporosis, memprediksi risiko fraktur, dan mengevaluasi performa tulang dengan menggunakan padded box. Tujuan penelitian ini adalah untuk mengetahui pengaruh peletakan garis padded box pada pemeriksaan hip joint kasus osteoporosis bulan Januari- Maret 2024 di Rumah Sakit Santo Borromeus. Jenis penelitian ini adalah deskriptif kualitatif. Data diambil melalui teknik observasi pemeriksaan, wawancara terhadap dokter spesialis radiologi dan radiografer, dan studi dokumen radiograf pasien. Kemudian, data tersebut diolah dan disajikan dalam bentuk uraian berisi hasil observasi dan pendapat - pendapat dari responden untuk mendapatkan simpulan dan saran. Hasil analisis menunjukkan bahwa peletakan garis padded box pada pemeriksaan DXA BMD kasus osteoporosis di Instalasi Radiodiagnostik, Imajing dan Radiologi Intervensi Rumah Sakit Santo Borromeus Bandung yang dilakukan pada titik hip joint harus diletakkan tepat di daerah neck femur dan tidak mengenai trochanter mayor, trochanter minor, ischium ataupun bagian lain. Peletakan padded box di tempat yang tepat memengaruhi akurasi hasil perhitungan nilai T-score atau Z-score untuk memprediksi resiko fraktur di masa yang akan datang.
Pemanfaatan Bioplastik Timbal untuk Menurunkan Dosis Radiasi pada Pemeriksaan Femur dengan Posisi Detektor Potret dan Diagonal melalui Pendekatan Citra dan Anatomi: RADIATION DOSE REDUCTION IN FEMUR EXAMINATION USING LEAD BIOPLASTICS: AN IMAGING AND ANATOMICAL APPROACH Alvin Fachrully Septiano; Oktarina Damayanti
JURNAL TERAS KESEHATAN Vol 8 No 2 (2025): Jurnal Teras Kesehatan
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat (LPPM) Politeknik Al Islam Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.38215/jtkes.v8i2.210

Abstract

X-ray radiation in the medical field offers substantial diagnostic benefits but also poses potential risks to both patients and medical personnel. This study aims to evaluate the effectiveness of bioplastic made from cassava starch and lead acetate as a radiation dose absorber in femur radiographic examinations. The examinations were conducted using Anteroposterior (AP) and Lateral projections with portrait and diagonal detector positions. Image processing utilized the Gaussian High Pass Filter (GHPF) method with cut-off frequencies of 5, 10, and 15 Hz. Image analysis was performed using Contrast to Noise Ratio (CNR) and Peak Signal to Noise Ratio (PSNR). The results indicated that the use of bioplastic reduced CNR and PSNR values compared to examinations without bioplastic, although the image quality remained within acceptable clinical limits. For instance, in the AP diagonal projection with a 5 Hz cut-off, the CNR value for the proximal femur was 22.86 (with bioplastic) versus 21.95 (without bioplastic), while the corresponding PSNR values were 11.1 and 11.6, respectively. Additionally, radiation dose attenuation was supported by increased Mean Squared Error (MSE) values, indicating effective shielding by the bioplastic. Cut-off frequencies of 5 and 10 yielded the best image quality in both conditions.
Reduksi dosis radiasi pemeriksaan femur dengan bioplastik timbal: pendekatan citra dan anatomi Oktarina Damayanti; Alvin Fachrully Septiano
JURNAL TERAS KESEHATAN Vol 8 No 2 (2025): Jurnal Teras Kesehatan
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat (LPPM) Politeknik Al Islam Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.38215/mpr3bs83

Abstract

X-ray radiation plays a vital role in medical diagnostics but carries potential risks for both patients and healthcare workers. This study evaluates the effectiveness of cassava starch–based bioplastic combined with lead acetate as an absorber of radiation dose during femur radiographic examinations. The tests were performed using Anteroposterior (AP) and Lateral projections with both portrait and diagonal detector positions. Image processing applied the Gaussian High Pass Filter (GHPF) method at cut-off frequencies of 5, 10, and 15 Hz. Image quality was analyzed through Contrast to Noise Ratio (CNR) and Peak Signal to Noise Ratio (PSNR). Results showed that the use of bioplastic slightly decreased CNR and PSNR values compared to examinations without bioplastic; however, the quality remained within acceptable diagnostic standards. For example, in AP diagonal projection at 5 Hz, CNR reached 22.86 (with bioplastic) versus 21.95 (without), while PSNR values were 11.1 and 11.6, respectively. Increased Mean Square Error (MSE) values confirmed radiation attenuation, supporting effective shielding. Optimal image quality occurred at 5–10 Hz cut-offs, while 15 Hz produced misleading impressions of osteoporosis. Overall, lead-based bioplastic effectively reduces radiation dose while preserving diagnostic value, offering a safer and eco-friendly alternative in radiographic imaging.
Komparasi Treatment Planning Pada Kanker Leher Rahim Menggunakan Teknik 3DCRT dan IMRT suwandi; Damayanti, Oktarina; Ningrum, Surdiyah Asri
JURNAL TERAS KESEHATAN Vol 6 No 1 (2023): Jurnal Teras Kesehatan
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat (LPPM) Politeknik Al Islam Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.38215/jtkes.v6i1.104

Abstract

Cancer is a non-communicable disease that is still a health problem in the world, including Indonesia. About 50 percent of cancer treatments worldwide are performed using radiotherapy. In its implementation, radiotherapy includes several stages, one of which is treatment planning. This study aims to assess the difference in dose received by PTV and OARs in planning using IMRT and 3DCRT techniques in cervical cancer patients. The method used in this study is scanning using a CT simulator, delineating PTV and healthy organs around the tumor (OARs), and planning using treatment planning system software. The results showed that in OARs, 3DCRT planning resulted in a dose of 4000 cGy by hitting 58.28% of the buli volume, and a dose of 5000cGy by hitting 17.76% of the rectum volume. While planning IMRT, a dose of 4000cGy hits 31.50% of the buli volume, and a dose of 5000cGy hits 12.29% of the rectum volume. In PTV, the doses produced by 3DCRT and IMRT planning were 4750cGy and 4750 cGy, and hit 95.18% and 98.71% of PTV volume, respectively. This study concludes that planning using IMRT is better than planning using 3DCRT in cases of cervical cancer. T