Studi Kualitas Air Reverse Osmosis Secara Mikrobiologi pada Dua Unit Hemodialisis di Kota Bandung cahyadi, adi imam; Ruslami, Rovina; Sudigdoadi, Sumaryati
Jurnal Sistem Kesehatan Vol 1, No 3 (2016): Volume 1 Nomor 3 Maret 2016
Publisher : Universitas Padjadjaran

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (429.453 KB) | DOI: 10.24198/jsk.v1i3.10352

Abstract

Kontaminasi bakteri pada air reverse osmosis (RO) yang digunakan untuk hemodialisis (HD) dapat menyebabkan respon inflamasi, termasuk inflamasi kronis. Pasien HD memiliki risiko kematian yang tinggi akibat kejadian kardiovaskular yang berkaitan erat dengan inflamasi kronis. Penelitian ini bertujuan untuk mengetahui gambaran kualitas air RO dan jenis bakteri kontaminan pada saluran distribusi unit HD di Kota Bandung secara mikrobiologi. Enam belas sampel air diambil dari unit HD di dua rumah sakit (RS) pada bulan September 2014, sebelas sampel dari unit HD di RS A dan lima dari unit HD di RS B, secara langsung pada titik sebelum dan sesudah proses RO. Sampel air diinokulasi pada Reasoner’s agar (R2A), koloni bakteri yang tumbuh kemudian diisolasi dan diidentifikasi di laboratorium Mikrobiologi Rumah Sakit Pendidikan (RSP) Unpad. Sampel air dari RS A menunjukkan pertumbuhan koloni bakteri 213-1473 cfu/mL. Sampel dari RS B menunjukkan pertumbuhan koloni 0-99 cfu/mL. Pada identifikasi didapatkan 12 spesies bakteri yang terdiri dari 8 spesies batang gram negatif, 3 spesies kokus gram positif, dan 1 spesies batang gram positif. Kualitas air RO unit HD RS A masih rendah karena hitung koloni yang tinggi dan perlu segera diperbaiki, pada RS B masih dalam batas yang diperbolehkan.Kata kunci: Hemodialisis; kontaminasi bakteri; reverse osmosis
Destructive Effect of Calcium Hypochlorite against Pseudomonas aeruginosa Biofilm Arifani, Ilma; Pradini, Gita Widya; Desy Arya, Insi Farisa; Cahyadi, Adi Imam
Althea Medical Journal Vol 4, No 3 (2017)
Publisher : Althea Medical Journal

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (681.179 KB) | DOI: 10.15850/amj.v4n3.1205

Abstract

Background: Pseudomonas aeruginosa is the most common bacteria contaminating the hemodialysis water and has high capability to form a biofilm. The presence of biofilm is hazardous because it becomes a constant source of bacterial and toxin release toward the hemodialysis patient’s blood. Calcium hypochlorite (Ca(OCl)2) is an easily obtained disinfectant. This study was aimed to detect the destructive effect of Ca(OCl)2 against P. aeruginosa biofilm and the optimal disinfectant concentration required to achieve significant effect.Methods: This experimental study was conducted in six replicates from September to October 2015 in Microbiology Laboratory of Faculty of Medicine Universitas Padjadjaran Bandung. A modified tissue culture plate method was performed to grow P. aeruginosa biofilms which were subsequently treated with Ca(OCl)2 in various chlorine concentrations, namely 20, 30, 40, and 500 parts per million (ppm). The data was analyzed using Welch Analysis of Variance (ANOVA) and Games-Howell post-hoc tests and presented in tables.Results: Data were obtained from 36 flat-bottomed polystyrene wells. There was a statistically significant mean difference between groups [F(4, 11.92)= 91.198, p<0.001)]. All of the tested chlorine concentrations caused significant decreases in biofilm optical densities (p = 0.027 for 20 ppm and p< 0.001 for 30, 40, and 500 ppm).Conclusions: Ca(OCl)2 with chlorine concentrations of 20, 30, 40, and 500 ppm have significant destructive effect against P. aeruginosa biofilm. The mean differences among treated groups were not significant. The most optimum concentration is 30 ppm.
Kajian Pustaka: Resistensi Escherichia coli Terhadap Berbagai Macam Antibotik pada Hewan dan Manusia Nurjanah, Gina Siti; Cahyadi, Adi Imam; Windria, Sarasati
Indonesia Medicus Veterinus Vol 9 (6) 2020
Publisher : Faculty of Veterinary Medicine, Udayana University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.19087/imv.2020.9.6.970

Abstract

Resistensi antibiotik merupakan salah satu permasalahan yang cukup serius dalam dunia kesehatan. Terjadinya resistensi bakteri terhadap antibiotik menyebabkan pengobatan penyakit akibat infeksi tidak lagi efisien karena turun atau hilangnya efektivitas obat. Salah satu bakteri yang banyak resisten terhadap antibiotik adalah Escherichia coli. Kajian ini bertujuan untuk mengetahui resistensi E. coli terhadap berbagai macam antibiotik pada hewan dan manusia serta mengetahui mekanisme resistensi E. coli terhadap antibiotik. Berdasarkan kajian ini diperoleh data bahwa E. coli banyak ditemukan telah resisten terhadap antibiotik golongan ?-lactam. Namun, beberapa antibiotik yang cukup sensitif terhadap E. coli yaitu kloramfenikol dan ciprofloksasin. Mekanisme resistensi pada E. coli terdapat empat mekanisme antara lain yaitu ?-lactamase (ESBL, Carbapenemase, dan AmpC), modifikasi target, efflux pumps, dan purin loss.
Kajian Pustaka: Faktor-Faktor Virulensi Staphylococcus aureus yang Berperan Penting dalam Kejadian Mastitis pada Sapi Perah Larasati, Savira Azhari; Windria, Sarasati; Cahyadi, Adi Imam
Indonesia Medicus Veterinus Vol 9 (6) 2020
Publisher : Faculty of Veterinary Medicine, Udayana University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.19087/imv.2020.9.6.984

Abstract

Staphylococcus aureus memiliki kepentingan di dunia kedokteran hewan sebagai agen penyebab mastitis pada sapi perah. Bakteri S. aureus dapat menghasilkan bermacam faktor virulensi yang dapat membantu patogen ini dalam setiap tahap proses patogenesis mastitis, dimulai dari perlekatan S. aureus ke sel ambing hingga menimbulkan kerusakan yang menyebar ke jaringan ambing. Penelitian ini merupakan penelitian studi literatur yang dilakukan dengan mengumpulkan dan menelaah berbagai artikel ilmiah yang terkait dengan topik penelitian ini melalui mesin pencari Google Scholar (https://scholar.google.co.id). Penelitian ini bertujuan untuk mengulas karakteristik beberapa faktor virulensi S. aureus yang sering dilaporkan berperan dalam kejadian mastitis pada sapi perah. Faktor virulensi tersebut antara lain yaitu biofilm, clumping factor, fibronectin binding protein, hemolisin, koagulase, Panton-Valentine leukocidin, kapsul, dan superantigen seperti toksin toxic shock syndrome (TSST), serta enterotoksin (SE). Kombinasi produksi faktor virulensi oleh S. aureus dianggap dapat meningkatkan derajat keparahan mastitis.
Kajian Pustaka: Komparasi Metode Deteksi Mastitis Subklinis Najwa Namira; Adi Imam Cahyadi; Sarasati Windria
Acta VETERINARIA Indonesiana Vol. 10 No. 1 (2022): Maret 2022
Publisher : IPB University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29244/avi.10.1.39-50

Abstract

Mastitis subklinis merupakan radang pada kelenjar susu yang menyerang ternak penghasil susu. Ambing ternak yang terinfeksi akan tampak normal, namun ternak akan mengalami penurunan produksi serta kualitas susu. Deteksi dini mastitis subklinis penting bagi peternak untuk mengurangi kerugian ekonomi. Berbagai macam metode deteksi untuk mendiagnosis mastitis subklinis telah tersedia. Studi komparasi ini dilakukan untuk mengetahui sensitivitas, spesifisitas, kelebihan, dan kekurangan dari metode-metode deteksi mastitis subklinis yang dapat dilakukan di lapangan seperti California Mastitis Test (CMT), Surf Field Mastitis Test (SFMT), Milk Electrical Conductivity (EC), Infrared Thermography (IRT), pH Detector, White Side Test (WST), dan Somatic Cell Counted (SCC). Jenis penelitian yang digunakan yaitu kajian pustaka dari literatur yang dikumpulkan sesuai dengan topik. Hasil penelitian menunjukkan bahwa CMT memiliki sensitivitas dan spesifisitas yang tinggi dan dapat digunakan sebagai metode alternatif dalam mendiagnosis mastitis subklinis. Waktu deteksi yang singkat, penggunaannya yang praktis, dan ketersediaan CMT di berbagai tempat dapat digunakan sebagai alternatif metode tes skrining dalam mendiagnosis mastitis subklinis.
Destructive Effect of Calcium Hypochlorite against Pseudomonas aeruginosa Biofilm Ilma Arifani; Gita Widya Pradini; Insi Farisa Desy Arya; Adi Imam Cahyadi
Althea Medical Journal Vol 4, No 3 (2017)
Publisher : Faculty of Medicine Universitas Padjadjaran

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (681.179 KB) | DOI: 10.15850/amj.v4n3.1205

Abstract

Background: Pseudomonas aeruginosa is the most common bacteria contaminating the hemodialysis water and has high capability to form a biofilm. The presence of biofilm is hazardous because it becomes a constant source of bacterial and toxin release toward the hemodialysis patient’s blood. Calcium hypochlorite (Ca(OCl)2) is an easily obtained disinfectant. This study was aimed to detect the destructive effect of Ca(OCl)2 against P. aeruginosa biofilm and the optimal disinfectant concentration required to achieve significant effect.Methods: This experimental study was conducted in six replicates from September to October 2015 in Microbiology Laboratory of Faculty of Medicine Universitas Padjadjaran Bandung. A modified tissue culture plate method was performed to grow P. aeruginosa biofilms which were subsequently treated with Ca(OCl)2 in various chlorine concentrations, namely 20, 30, 40, and 500 parts per million (ppm). The data was analyzed using Welch Analysis of Variance (ANOVA) and Games-Howell post-hoc tests and presented in tables.Results: Data were obtained from 36 flat-bottomed polystyrene wells. There was a statistically significant mean difference between groups [F(4, 11.92)= 91.198, p<0.001)]. All of the tested chlorine concentrations caused significant decreases in biofilm optical densities (p = 0.027 for 20 ppm and p< 0.001 for 30, 40, and 500 ppm).Conclusions: Ca(OCl)2 with chlorine concentrations of 20, 30, 40, and 500 ppm have significant destructive effect against P. aeruginosa biofilm. The mean differences among treated groups were not significant. The most optimum concentration is 30 ppm.
Detection of Entamoeba sp. and Helmith Eggs From Water Sources in Urban Slum Area in Bandung Municipality Sri Yusnita Irda Sari; M. Ersyad Hamda; Adi Imam Cahyadi Cahyadi; Jasmine Maulinda Utami; Mogenes Ravichandran; Ardini Raksanagara
Jurnal Kesehatan Masyarakat Andalas Vol 11, No 1 (2016): Jurnal Kesehatan Masyarakat Andalas
Publisher : Faculty of Public Health, Andalas University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24893/jkma.v11i1.216

Abstract

Diarrhea is a waterborne disease due to consumption of contaminated food/water. People in urban slum area have highest risk to get diarrhea because of poor hygiene and sanitation as well as limited access to uncontaminated water. This study aimed to identify conta­mination in watersources by Entamoeba Sp and helmint eggs (Anchylostoma duodenale, Ascaris lumbricoides, Trichuris trichuria) in one of urban slum area in Bandung municipality. Samples were taken from 123 watersources (74 tap water, 21 borehole, 22 dugwell and 6 spring water) which was randomly selected in 10 RW along the Cikapundung river basin in Tamansari subdistrict during period of July-September 2015. Water samples were examined by PCR to detect Entamoeba Sp and microscopic identification for helminth eggs. 90 out of 123 samples were positive for Entamoeba Sp (59 tap water, 16 dugwell, 11 borehole and 4 spring water). Helminth egg of Ascaris lumbricoides was detected from unimproved common dugwell which had very high risk of contamination. Appropriate of water treatment prior to consumption is vastly important. Physical improvement to construct improved dugwell should be done to prevent contamination from helminth eggs in watersources.
Studi Kualitas Air Reverse Osmosis Secara Mikrobiologi pada Dua Unit Hemodialisis di Kota Bandung adi imam cahyadi; Rovina Ruslami; Sumaryati Sudigdoadi
Jurnal Sistem Kesehatan Vol 1, No 3 (2016): Volume 1 Nomor 3 Maret 2016
Publisher : Universitas Padjadjaran

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (429.453 KB) | DOI: 10.24198/jsk.v1i3.10352

Abstract

Kontaminasi bakteri pada air reverse osmosis (RO) yang digunakan untuk hemodialisis (HD) dapat menyebabkan respon inflamasi, termasuk inflamasi kronis. Pasien HD memiliki risiko kematian yang tinggi akibat kejadian kardiovaskular yang berkaitan erat dengan inflamasi kronis. Penelitian ini bertujuan untuk mengetahui gambaran kualitas air RO dan jenis bakteri kontaminan pada saluran distribusi unit HD di Kota Bandung secara mikrobiologi. Enam belas sampel air diambil dari unit HD di dua rumah sakit (RS) pada bulan September 2014, sebelas sampel dari unit HD di RS A dan lima dari unit HD di RS B, secara langsung pada titik sebelum dan sesudah proses RO. Sampel air diinokulasi pada Reasoner’s agar (R2A), koloni bakteri yang tumbuh kemudian diisolasi dan diidentifikasi di laboratorium Mikrobiologi Rumah Sakit Pendidikan (RSP) Unpad. Sampel air dari RS A menunjukkan pertumbuhan koloni bakteri 213-1473 cfu/mL. Sampel dari RS B menunjukkan pertumbuhan koloni 0-99 cfu/mL. Pada identifikasi didapatkan 12 spesies bakteri yang terdiri dari 8 spesies batang gram negatif, 3 spesies kokus gram positif, dan 1 spesies batang gram positif. Kualitas air RO unit HD RS A masih rendah karena hitung koloni yang tinggi dan perlu segera diperbaiki, pada RS B masih dalam batas yang diperbolehkan.Kata kunci: Hemodialisis; kontaminasi bakteri; reverse osmosis
Hyperferritinemia Correlated with Activated Population of Natural Killer Cells in Pediatric Major β-Thalassemia Patients Adi Imam Cahyadi; Mohammad Ghozali; Reni Ghrahani; Lelani Reniarti; Ramdan Panigoro
Global Medical & Health Communication (GMHC) Vol 9, No 1 (2021)
Publisher : Universitas Islam Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1835.552 KB) | DOI: 10.29313/gmhc.v9i1.6346

Abstract

Natural killer (NK) cells act both as cytotoxic and cytokine producers in the innate immune response. Hyperferritinemia resulting from a routine blood transfusion as a specific treatment in major β-thalassemia patients may disturb the cellular immune system’s harmony. This study aims to investigate the correlation between hyperferritinemia and the NK cell subsets in major β-thalassemia settings. Pediatric major β-thalassemia patients who routinely received a blood transfusion at Dr. Hasan Sadikin General Hospital in 2016 were included in this cross-sectional study. Blood samples were treated with the monoclonal antibody of CD3, CD56, and CD16 to count the NK cells subsets as CD56bright, CD56dim, and CD16+ using flowcytometry. CD69+ used as an activation marker. The median fluorescence intensity (MFI) of CD56, CD16, and CD69 was measured. Total iron-binding capacity (TiBC), ferritin, and serum iron level examined as iron status. A Spearman correlation test was used for statistical analysis. Fifty-five blood samples were obtained for analysis. This study reveals that the percentage of CD3− lymphocyte population was correlated with the ferritin levels (r=−0.45, p=0.0009). Positive correlation was revealed between activated population (CD69+) of CD56bright and CD56dim NK cell subsets and hyperferritinemia [(r=0.353, p=0.008) and (r=0.355, p=0.008)]. The activated CD56bright cells was associated with ferritin level (r=0.353, p=0.008) and TiBC (r=0.334, p=0.018). Hyperferritinemia in pediatric major β-thalassemia patients may influence NK cell subsets' balance population, particularly the CD56bright and CD56dim NK cell subsets, then alter their immune response to pathogens. KORELASI ANTARA HIPERFERITINEMIA DAN SEL NATURAL KILLER TERAKTIVASI PADA ANAK DENGAN TALASEMIA BETA MAYORSel-sel natural killer (NK) telah diketahui memiliki peran sitotoksik dan dalam produksi sitokin pada respons imun bawaan. Hiperferitinemia merupakan hasil dari transfusi darah rutin yang dijalani sebagai terapi utama pada talasemia mayor. Penelitian ini bertujuan mempelajari hubungan hiperferitinemia dan sel NK pada talasemia beta mayor. Penelitian potong lintang ini melibatkan anak dengan talasemia beta mayor yang secara rutin menerima transfusi darah di RSUP Dr. Hasan Sadikin selama tahun 2016. Sampel darah diberi marker CD3, CD56, dan CD16 untuk menghitung subset sel NK sebagai CD56bright, CD56dim, dan CD16+ menggunakan flowcytometry. CD69+ digunakan sebagai penanda aktivasi. Median fluorescence intensity (MFI) CD56, CD16, dan CD69 diukur. Kadar TiBC, ferritin, dan Fe serum diperiksa sebagai status besi. Uji korelasi Spearman digunakan pada analisis statistik. Analisis dilakukan terhadap 55 sampel darah anak dengan talasemia. Penelitian ini mendapatkan populasi limfosit CD3 berkorelasi dengan kadar feritin (r=−0,45; p=0,0009). Korelasi positif didapatkan pada populasi teraktivasi (CD69+) dari subset sel CD56bright dan CD56dim NK serta hiperferitinemia [(r=0,353; p=0,008) dan (r=0,355; p=0,008)]. Sel CD56bright teraktivasi berkorelasi dengan kadar feritin (r=0,353; p=0,008) dan TiBC (r=0,334; p=0,018). Hiperferitinemia pada anak dengan talasemia mayor dapat memengaruhi populasi sel NK, khususnya pada subset CD56bright dan CD56dim sehingga berpengaruh pada respons imun terhadap patogen.
The Effectiveness of Ultraviolet, Ozonization and Reverse Osmosis as Disinfection Method in Drinking Water Refill Stations Sri Yusnita Irda Sari; Muhamad Iqbal; Adi Imam Cahyadi; Titik Respati; Ardini Saptaningsih Raksanagara; Ridad Agoes
Global Medical & Health Communication (GMHC) Vol 6, No 3 (2018)
Publisher : Universitas Islam Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (798.487 KB) | DOI: 10.29313/gmhc.v6i3.3427

Abstract

The number of drinking water refill stations (DWRS) was increased rapidly because high of mid-low urban community need to get affordable drinking water. Water treatment methods in DWRS are varying even many DWRS uses more than one disinfection method to increase the effectiveness. The quality of many DWRS productions was reported unstandardized, however not yet the study to evaluate the effects of the water treatment method used. This study aimed to compare the effectiveness of various water treatment methods in DWRS to identify which method is the most effective. The study used a cross-sectional approach conducted in 3 groups of water treatment methods, namely ultraviolet, ultraviolet + ozonization, and a combination of ultraviolet + ozonization + reverse osmosis with each group consisted of 40 DWRS. The survey was conducted in July–September 2017 in Bandung municipality by structured interview. Examination of microbiological parameters of raw and processed drinking water samples using membrane filter method. Water samples from raw water and drinking water from treatment process were taken from each DWRS to be tested for the microbiological parameter by using the membrane filter method. Comparison of the effectiveness was analyzed using the Wilcoxon rank sum test and assessment of log removal reduction. The result showed that there was significantly different in the effectiveness of coliform removal between the three groups. The improvement for controlling and training particularly for the procedure and maintenance of water treatment equipment to the owners/workers in DWRS is urgently needed as the concern of related authority. In conclusion, the water treatment method using reverse osmosis and ultraviolet is the most effective disinfection method compared to the ozonization method. The usage of more that one method of water treatment at the same time relate to the lower percentage of the effectiveness compares to the usage of only one method. EFEKTIVITAS ULTRAVIOLET, OZONISASI, DAN REVERSE OSMOSIS SEBAGAI METODE DESINFEKSI DEPOT AIR MINUM ISI ULANGPerkembangan depot air minum isi ulang (DAM) melaju dengan pesat karena masyarakat menengah ke bawah perkotaan membutuhkan air minum dengan harga yang terjangkau. Metode pengolahan air baku menjadi air minum di DAM bervariasi bahkan tidak jarang digunakan lebih dari satu metode desinfeksi untuk meningkatkan efektivitasnya. Kualitas produksi DAM banyak yang dilaporkan tidak sesuai dengan standar, namun belum terdapat penelitian yang mengevaluasi pengaruh metode pengolahan air yang digunakan. Penelitian ini bertujuan membandingkan efektivitas berbagai metode pengolahan air di DAM sehingga dapat diketahui metode apa yang paling efektif. Penelitian ini menggunakan pendekatan cross-sectional yang dilakukan pada 3 kelompok metode pengolahan air, yaitu ultraviolet, ultraviolet + ozonisasi, dan kombinasi ultraviolet + ozonisasi + reverse osmosis dengan tiap-tiap kelompok terdiri atas 40 DAM. Survei dilakukan pada Juli–September 2017 di Kota Bandung dengan melakukan wawancara terstruktur. Sampel air baku dan air minum hasil olahan diambil dari setiap DAM untuk diperiksa parameter mikrobiologinya menggunakan metode filter membran. Perbandingan efektivitas dianalisis menggunakan Wilcoxon rank sum test dan penilaian log removal reduction. Hasil penelitian menunjukkan bahwa terdapat perbedaan efektivitas yang signifikan pada ketiga kelompok terutama efektivitas terhadap coliform. Perlu upaya pengawasan dan pelatihan khususnya mengenai teknis pemakaian dan pemeliharaan alat pada pemilik/pekerja DAM yang harus menjadi perhatian pemerintah dan pihak terkait. Simpulan, metode pengolahan air menggunakan reverse osmosis dan ultraviolet merupakan metode desinfeksi yang paling efektif dibanding dengan metode ozonisasi. Pemakaian lebih dari satu metode desinfeksi pada saat yang bersamaan menyebabkan persentase efektivitas menjadi lebih rendah dibanding dengan yang menggunakan hanya satu jenis metode desinfeksi.