MESIN PENCACAH PLASTIK (PLASTIC SHREDDER) Rezki, Miftahul; Ridwan, Muh.; Susanty, Asty Dewi; Rahmayana, Rahmayana; Ulfa, Sri; Muhammad H, Fadhil; Arya Apriansyah, Arya Apriansyah; Fathir, Lukman; Agustin, Mulfi Jumliah; Ilham, Ilham; Piter, Herwin; Ismirawati, Nur
Community Services and Social Work Bulletin Vol 1, No 2 (2021): Community Services and Social Work Bulletin Volume 1 No. 2 2021
Publisher : Universitas Muhammadiyah Tangerang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (718.199 KB) | DOI: 10.31000/cswb.v1i2.5871

Abstract

Plastic type material is a material that is often used by many people in everyday life, the use of plastic materials, especially working in the world of health, industry or household, many people make plastic materials such as glass, plates, and more used as the necessities of everyday life. The sheer amount of plastic use has the potential to increase Polluttion and it is also very bad for the environment, mostly plastic materials are dumped without further processing, to reduce the impact of plastic materials needed for chopping tools to reduce the accumulation process. Using an AC motor as a drive system for chopping the plastic can make the plastic into a smaller part.
Sistem Monitoring dan Kendali Tegangan 3 Phase Pompa Air PDAM Berbasis ESP32 Zainal, Muhammad; Piter, Herwin; Syafar, A. Muhammad
Jurnal Sintaks Logika Vol. 5 No. 3 (2025): September 2025
Publisher : Fakultas Teknik Universitas Muhammadiyah Parepare

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31850/jsilog.v5i3.4259

Abstract

Currently PDAM 3-phase water pump voltage monitoring is still manual, handling problems such as damage, loss of phase voltage, is difficult to detect quickly. However, this research aims to make it easier and save time in monitoring the voltage and current on the panel, especially when the voltage on one of the phases does not match the specified parameters. This research uses an experimental method, by testing the function of a series of tools using ESP32, PZEM 004T Sensor, I2C LCD Module, SSR Module, Buzzer, and the Telegram Bot application as data receivers. The research results show that this tool can identify problems that occur on the panel. The results of the measurement data for voltage readings on measuring instruments and sensors show an error rate in the R phase = 0.34%, S phase = 0.32%, T phase = 0.52% and comparison results in the current phase R = 6.7%, S phase = 2.3% T phase=3.56%. The sensors used to read voltage and current have a low error rate and are good to use.