Claim Missing Document
Check
Articles

Found 2 Documents
Search

Transportation Efficiency Based On Empowerment Of Private And Government Businesses With The Concept Of Collaboration Amrullah, Romanda Annas; Moejiono; Nofandi, Faris; Santoso, Agus Dwi; Arleiny; Pratama, Rizki Adi
Meteor STIP Marunda Vol 17 No 2 (2024): December
Publisher : Pusat Penelitian dan Pengabdian kepada Masyarakat (P3M) STIP Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36101/msm.v17i2.384

Abstract

The disproportionate growth between the transportation fleet and the infrastructure causes congestion, pollution, inconvenience and poor service. However, the high growth in transportation fleets managed by the private sector more than those managed by the government is not effective, on the other hand the government does not have enough funds to provide adequate public transportation facilities, so the concept of Allocation Cheap Sourcing is needed which is a collaboration between fleets managed by the private sector and the government. The method used in this study is Evidence based policy . The results of the study show that the effectiveness of collaboration can be in the form of partnerships and new forms of organization (NFO).
Analysis of Performance Degradation of the Refrigeration System on MT Nolowati III Sahrul Romadon; Moejiono; Mochammad Zainuddin; Agus Prawoto; Prima Yudha Yudianto
Journal of Engineering Science and Technology Management (JES-TM) Vol. 6 No. 2 (2026): JES-TM 2026
Publisher : Journal of Engineering Science and Technology Management

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/jestm.v6i2.408

Abstract

The refrigeration unit, also known as the refrigerator, is a crucial auxiliary machine on board the MT Nolowati III, as it is responsible for ensuring the crew remains healthy and refreshed. A common operational issue is the refrigeration unit's inability to reach its designated operating temperature. This includes the meat compartment (-10°C to -12°C) and the vegetable/fruit compartment (+4°C to +10°C). Suboptimal supporting components such as the compressor and thermostat, as well as a lack of standard maintenance, contribute to this issue. Analysis shows that the decline in performance is mostly caused by technical factors, such as dirt covering the condenser or thermostat errors, which disrupt the refrigeration cycle and cause temperature increases. To prevent this, preventative measures focus on regular maintenance, routine condenser cleaning, and performing maintenance work according to the manual's instructions.