cover
Contact Name
Arif Fadllullah
Contact Email
jeb.ubt@gmail.com
Phone
+6281258493637
Journal Mail Official
jeb.ubt@gmail.com
Editorial Address
Gedung D Lt. 3 Kampus Universitas Borneo Tarakan. Jl. Amal Lama No. 1, Tarakan, Kalimantan Utara, Indonesia. Kodepos: 77123.
Location
Kota tarakan,
Kalimantan utara
INDONESIA
Elektrika Borneo
ISSN : 24430986     EISSN : 2685001X     DOI : -
Elektrika Borneo (JEB) (p-ISSN 2443-0986 dan e-ISSN 2685-001X) merupakan jurnal saintek yang diterbitkan secara berkala sebanyak dua kali dalam setahun yaitu April dan Oktober oleh Jurusan Teknik Elektro, Fakultas Teknik, Universitas Borneo Tarakan. Fokus dan ruang lingkup jurnal ini adalah penelitian dan kajian tentang isu-isu mutakhir berkaitan dengan bidang ELEKTRIKA (Elektronika, Telekomunikasi, Listrik dan Informatika), khususnya untuk perkembangan kawasan perbatasan dan sumber daya laut tropis. Berikut ini merupakan penjelasan terkait sub bidang ELEKTRIKA: Elektronika (sensor aktuator, sistem elektronika, instrumentasi industri, material, mikroelektronika, embedded system, sistem kendali dan rangkaian terintegrasi). Telekomunikasi (jaringan telekomunikasi, antena, jalur transmisi, pengolahan sinyal dan komunikasi radio, peralatan wireless-mobile, dan skema routing). Listrik (pembangkit listrik, transmisi, distribnusi, elektronika daya, kualitas daya, tenaga dan arus tinggi, proteksi daya, konversi energi, dan energi terbarukan). Informatika (arsitektur komputer, algoritma pemrograman, sistem informasi, komputasi cerdas, visi komputer, sistem temu kembali informasi dan jaringan komputer). Naskah yang masuk merupakan artikel yang up-to-date dan akan diseleksi melalui proses peer reviewers oleh mitra bestari.
Articles 136 Documents
ANALISIS PENINGKATAN TINGKAT KANDUNGAN DALAM NEGERI PADA PRODUK REVERSE ENGINEERING MENGGUNAKAN METODE AHP DAN QFD: STUDI KASUS GRAB BUCKET SHIP UNLOADER PLN PUSHARLIS Mhammad Choerul Umar; Zainal Arifin; Ahmad Mamba Udin
Elektrika Borneo Vol 12, No 1 (2026): Elektrika Borneo Edisi April
Publisher : Jurusan Teknik Elektro, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/eb.v12i1.7048

Abstract

PLN Pusharlis UP2W VI Surabaya, sebagai salah satu unit penunjang PT PLN (Persero), telah mengembangkan produk unggulan manufaktur Grab Bucket Ship Unloader (GBSU) Type Scissor 30 Ton melalui proses reverse engineering. Untuk mendukung perusahaan dalam meningkatkan Tingkat Kandungan Dalam Negeri (TKDN) di lingkungan PT PLN (Persero), PLN Pusharlis berkomitmen untuk terus meningkatkan nilai TKDN dari setiap produk yang diproduksinya, sebagaimana dibuktikan oleh sertifikasi TKDN yang dikeluarkan oleh lembaga yang berwenang. Analytical Hierarchy Process (AHP) digunakan untuk mengidentifikasi faktor-faktor kunci yang berkontribusi terhadap rendahnya nilai TKDN dalam proses produksi berbasis reverse engineering pada produk GBSU, sedangkan metode Quality Function Deployment (QFD) digunakan untuk menentukan respons teknis dan tingkat prioritasnya untuk mengembangkan rencana strategis untuk meningkatkan nilai TKDN komponen GBSU, yang dimodelkan melalui House of Quality (HOQ). Sepuluh kriteria "Voice of Customer" digunakan untuk mendapatkan respons teknis, menghasilkan dua puluh satu respons teknis yang diprioritaskan yang dikonversi menjadi target perbaikan dalam HOQ. Temuan ini menunjukkan potensi peningkatan TKDN sebesar 73,87%. Berdasarkan respons teknis yang diprioritaskan, nilai TKDN diproyeksikan meningkat dari 26,13% menjadi 63,26%, yang menunjukkan peningkatan sebesar 37,17%.
KAJIAN KELAYAKAN CONDITION BASE MAINTENANCE TERHADAP INTERVAL OVERHAUL TM2500 PT PLN BATAM Arif Budiman; Syamsir Abduh; Marwan Rosyadi
Elektrika Borneo Vol 12, No 1 (2026): Elektrika Borneo Edisi April
Publisher : Jurusan Teknik Elektro, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/eb.v12i1.7267

Abstract

Inefisiensi biaya operasional akibat ketidakselarasan strategi pemeliharaan dengan degradasi aktual aset menjadi tantangan kritikal pada turbin gas aero-derivatif di sistem isolated grid. Praktik konvensional Time-Based Maintenance (TBM) yang memberlakukan interval overhaul kaku setiap 12.500 jam sering kali memicu over-maintenance, karena mengabaikan variabilitas kondisi termodinamika dan integritas mekanikal mesin. Penelitian ini mengusulkan transisi strategis menuju Condition-Based Maintenance (CBM) melalui pengembangan "Algoritma Gatekeeper" yang mengintegrasikan parameter termodinamika kritis (T48, PS3) dengan validasi visual langsung melalui Borescope Inspection (BSI). Pendekatan ini menempatkan data visual sebagai penentu akhir dalam keputusan ekonomi, memastikan keamanan teknis sebelum eksploitasi nilai ekonomi aset dilakukan. Melalui analisis tekno-ekonomi (Cost-Benefit Analysis) pada armada 20 unit TM2500 di PT PLN Batam, strategi ini terbukti mampu menghasilkan efisiensi signifikan. Hasil simulasi menunjukkan potensi penghematan biaya langsung sebesar USD 5.614.431 per tahun dengan nilai Benefit-Cost Ratio (BCR) mencapai 2,36. Temuan ini mengimplikasikan bahwa integrasi BSI dalam kerangka CBM bukan hanya meningkatkan reliabilitas, tetapi juga menetapkan standar manajemen aset baru yang adaptif dan efisien secara finansial.
EVALUASI SISTEM PENANGKAL PETIR DENGAN MENGGUNAKAN METODE SUDUT PROTEKSI PADA GEDUNG FAKULTAS KEDOKTERAN UNIVERSITAS BORNEO TARAKAN Sugeng Riyanto; Dwi Risky Oktavia
Elektrika Borneo Vol 12, No 1 (2026): Elektrika Borneo Edisi April
Publisher : Jurusan Teknik Elektro, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/eb.v12i1.7076

Abstract

Indonesia experiences a high frequency of thunderstorm days, which increases the vulnerability of multi-story buildings to lightning strikes. The Faculty of Medicine building at the University of Borneo Tarakan requires an evaluation of its lightning protection system to ensure safety and compliance. This study aims to analyze the effectiveness of the system using the Protection Angle Method and to measure the grounding resistance of the installed earthing system. The research applied a descriptive quantitative approach with a case study method. The analyzed parameters included building height, number of conductors, and soil resistivity, calculated based on SNI 03-7015-2004 and the General Regulation of Lightning Protection Installations (PUIPP). The results showed that with a building height of 25.3 meters, the system provided a protection radius of 25.3 meters and a protection efficiency of 0.91, classified as Protection Level III. However, several parts of the building were not optimally protected, requiring layout adjustments or additional air terminals. In conclusion, the lightning protection system is considered fairly effective, though improvements in grounding resistance and additional protection points are recommended to achieve full compliance with the standards..Indonesia merupakan salah satu negara dengan intensitas hari guruh tinggi, sehingga bangunan bertingkat berisiko besar terhadap sambaran petir. Gedung Fakultas Kedokteran Universitas Borneo Tarakan menjadi salah satu bangunan yang perlu dievaluasi sistem proteksi petirnya. Penelitian ini bertujuan menganalisis efektivitas sistem penangkal petir menggunakan metode sudut proteksi dan menilai resistansi tanah pada sistem pentanahan. Metode yang digunakan adalah kuantitatif deskriptif dengan pendekatan studi kasus, berdasarkan SNI 03-7015-2004 dan PUIPP. Hasil penelitian menunjukkan bahwa dengan tinggi bangunan 25,3 meter, sistem proteksi memiliki radius perlindungan 25,3 meter, luas area 11.673,5 m², dan efisiensi 0,91 (Proteksi Level III). Beberapa area belum terlindungi optimal dan nilai resistansi tanah perlu ditingkatkan agar sesuai standar. Secara keseluruhan, sistem proteksi petir dinilai cukup efektif, namun masih memerlukan perbaikan pada aspek pentanahan dan penambahan titik proteksi.
ANALISA IMPLEMENTASI CO-FIRING PADA PLTU SEBALANG 2 X 100 MW Refginanda Aknur; Tajuddin Nur; Joko Muslim
Elektrika Borneo Vol 12, No 1 (2026): Elektrika Borneo Edisi April
Publisher : Jurusan Teknik Elektro, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/eb.v12i1.7014

Abstract

- Pemerintah saat ini sangat memfokuskan perhatian pada pemanfaatan energi yang ramah lingkungan sebagai bagian dari upaya untuk mengurangi emisi karbon, dengan target untuk mencapai net zero emission pada tahun 2060, sesuai dengan ketentuan yang diatur dalam Paris Agreement dan juga sesuai Rencana Usaha Penyediaan Tenaga Listrik (RUPTL) PT PLN (Persero) tahun 2025-2034. Salah satu strategi kunci yang diterapkan adalah penggunaan bahan bakar alternatif, yang bertujuan untuk mengurangi ketergantungan pada bahan bakar fosil yang selama ini mendominasi sektor energi. Untuk menekan emisi dari pembangkit listrik tenaga uap berbahan bakar batu bara, salah satu metode yang dapat diterapkan adalah cofiring. Kebijakan ini berpotensi mempengaruhi kinerja peralatan yang ada di pembangkit, mengingat bahwa peralatan tersebut dirancang khusus untuk spesifikasi batu bara. Pada penelitian dilakukan untuk menganalisis dampak penggunaan biomassa terhadap peralatan utama di PLTU Sebalang dengan kapasitas 2 x 100 MW menggunakan software Aspen Plus V12.1 dengan komposisi biomassa sebanyak 5%, 10%, dan 15%, dengan woodchips sebagai jenis biomassa yang dipilih. Dari hasil simulasi didapatkan pada komposisi cofiring biomassa sebesar 15% emisi CO2 mengalami penurunan sebesar 4,43%, emisi SOx turun 12,45%, emisi NOx turun 18,42%, FGET turun 3,5% dan gross power turun 3,7%. Hasil simulasi sudah terverifikasi valid dengan data operasi PLTU saat ini pada komposisi cofiring 3% dan hasil uji performance cofiring 10% dan 20% oleh PLN Puslitbang dengan uji statistik rata-rata RMSE 8,04 MAE 8,04 dan MAPE 2,37.
DESAIN DAN ANALISA KERUGIAN SISTEM PLTS ATAP ON-GRID MENGGUNAKAN SOFTWARE PVSYST DI GEDUNG DINAS LINGKUNGAN HIDUP KABUPATEN MALINAU Fitriani Said; Abil Huda; Priskah Melati
Elektrika Borneo Vol 12, No 1 (2026): Elektrika Borneo Edisi April
Publisher : Jurusan Teknik Elektro, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/eb.v12i1.7274

Abstract

Current energy demand still largely relies on fossil energy sources such as petroleum, coal, and natural gas. However, the availability of fossil energy is gradually decreasing, thus a transition to renewable energy sources such as solar energy is necessary. PLTSA (Solar Power Plant) is a solar energy-based power generation system. The PLTSA system was designed for the Environmental Agency Office Building of Malinau Regency using PVsyst software with an on-grid system connected to the utility grid (PLN). The DLH building consumes 318 kWh of energy per day. The PLTSA was designed with a capacity of 69.8 kWp using a total of 128 solar modules installed on both sides of the roof, with 65 battery units and 4 inverters. From this design, the PLTSA is capable of producing 127,955 kWh/year. However, due to energy losses of 21.15%, the amount of electricity that actually reaches the user is only 100,886 kWh per year. By utilizing the PLTS, the DLH building can reduce its electricity expenses by up to IDR 112,461,660 per year. 
PERENCANAAN INSTALASI LISTRIK PADA GEDUNG SD MUHAMMADIYAH SIROJUDDIN MUNGKID Muhammad Khafid Masrukhan; Agung Trihasto; Hery Teguh Setiawan
Elektrika Borneo Vol 12, No 2 (2026): Elektrika Borneo Edisi Oktober
Publisher : Jurusan Teknik Elektro, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/eb.v12i2.7551

Abstract

Intisari— Penelitian ini bertujuan untuk merencanakan instalasi listrik pada Gedung SD Muhammadiyah Sirojuddin Mungkid berdasarkan standar Persyaratan Umum Instalasi Listrik (PUIL) 2020 guna menghasilkan sistem kelistrikan yang aman, andal, dan sesuai dengan kebutuhan operasional gedung sekolah. Penelitian dilakukan menggunakan metode observasi, pengukuran langsung, dan studi dokumentasi untuk memperoleh data kondisi bangunan, kebutuhan beban listrik, serta standar teknis yang berlaku. Tahapan perencanaan meliputi perhitungan sistem pencahayaan menggunakan metode lumen, analisis kebutuhan daya listrik, pemilihan penghantar dan pengaman, pembagian sirkit beban, perhitungan susut tegangan, serta penyusunan Rencana Anggaran Biaya (RAB). Hasil penelitian menunjukkan bahwa sistem instalasi listrik yang dirancang telah memenuhi standar PUIL 2020 melalui pembagian beban yang lebih seimbang, pemilihan penghantar dan perangkat pengaman yang sesuai dengan kapasitas arus, serta sistem pencahayaan yang memenuhi kebutuhan ruang belajar. Selain itu, hasil perencanaan menghasilkan sistem distribusi listrik yang aman dan efisien dengan total Rencana Anggaran Biaya (RAB) instalasi listrik sebesar Rp75.739.744. Hasil penelitian ini diharapkan dapat menjadi referensi dalam perencanaan instalasi listrik pada bangunan pendidikan sehingga mampu mendukung sistem kelistrikan yang aman, nyaman, dan berkelanjutan.
ANALISIS SENSITIVITAS HARGA TANAH DALAM PEMILIHAN TOWER COMPACT LATTICE DAN TOWER STANDAR PADA KORIDOR SUTET 500 KV PERKOTAAN Firmansyah Rizal; Aminullah Assagaf
Elektrika Borneo Vol 12, No 2 (2026): Elektrika Borneo Edisi Oktober
Publisher : Jurusan Teknik Elektro, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/eb.v12i2.7505

Abstract

The development of 500 kV Extra High Voltage Overhead Transmission Lines in urban areas is constrained by limited land availability and high land acquisition costs. This study evaluates the technical and financial feasibility of the 18.3 km Muara Tawar–Bekasi transmission corridor by comparing Compact Lattice Towers and conventional towers using technical, financial, and land-price sensitivity analyses. Unlike previous studies that focused on individual tower characteristics, this research adopts a transmission corridor-based approach integrating technical performance, spatial requirements, land costs, and investment feasibility. The results show that both tower designs satisfy technical requirements. Compact Lattice Towers reduce the right-of-way width from 34 m to 28 m, lowering land acquisition costs by 54.0% and ROW costs by 17.2%, although construction costs increase by 29.3%. Both alternatives remain financially feasible, with NPV values exceeding IDR 3.1 trillion and IRR values of approximately 21%. Sensitivity analysis identifies land price as the dominant factor influencing tower selection, with an economic break-even point of approximately IDR 2.57 million/m².
ANALISIS DAMPAK KEEKONOMIAN INVESTASI INFRASTRUKTUR SEKTOR KETENAGALISTRIKAN DI PROVINSI KALIMANTAN UTARA MENGGUNAKAN METODE INPUT OUTPUT LEONTIEF Jefry Palelleng; Tri Wahyu Adi
Elektrika Borneo Vol 12, No 2 (2026): Elektrika Borneo Edisi Oktober
Publisher : Jurusan Teknik Elektro, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/eb.v12i2.7523

Abstract

The development of electricity infrastructure is essential to support economic growth, industrial development, and community welfare, particularly in regions with isolated electrical systems and limited power supply. The government through PT PLN (Persero), allocates significant budget for investment in the electricity sector. In addition to accurate financial studies, an analysis of the economic impact of these investments is required. One of the projects implemented by PT PLN (Persero) are the construction of 150 kV High Voltage Overhead Lines and 150 kV Substations on Tanjung Selor – Tana Tidung – Malinau route in North Kalimantan. This study aims to analyze the impact of the investment in this project on regional economic growth and its influence on other industrial sectors. The analysis measures direct, indirect, and multiplier effects, as well as linkage analysis using the Leontief Input-Output method based on transaction data from 52 industrial sectors. The results show that the investment of these projects generates significant values on direct and indirect impact with the highest multiplier coefficient compared to other sectors. Backward and forward linkage indices analysis both result value greater than 1, indicates the electricity sector is a leading sector that capable to driving economic growth across other sectors in the Province.
ANALISIS DAN OPTIMASI DESIGN PLTS DI HYDROGEN PLANT: STUDI KASUS PLTU BANTEN 1 SURALAYA Aditia Setiaputra; Marwan Rosyadi
Elektrika Borneo Vol 12, No 2 (2026): Elektrika Borneo Edisi Oktober
Publisher : Jurusan Teknik Elektro, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/eb.v12i2.7560

Abstract

The Indonesian government's commitment to achieving Net Zero Emissions (NZE) by 2060. PT PLN has been developing a hydrogen ecosystem through the establishment of Hydrogen Refueling Stations and the production of green hydrogen utilizing existing hydrogen plant at their power generation facilities. Current solar power plant installed in Banten 1 Suralaya CFPP is unable to fully meet the electricity demand required for green hydrogen production. The existing PV system generates 37.145 MWh of electricity, whereas the annual energy demand of the hydrogen production equipment reaches 178.681 MWh. Monte Carlo simulation results indicate an energy deficit ranging 383-387 kWh per day for green hydrogen production. An added PV system was selected from several alternatives using the Analytical Hierarchy Process based on predefined criteria and alternatives. The selected location was the Maintenance Workshop area. System design and annual energy production were evaluated using PVsyst 8.0.6 simulation software. The simulation results show, added PV system can fully supply the hydrogen production equipment with NRE during the period from 09:00 AM to 03:00 PM. During these hours, PV generation exceeds the hydrogen production load demand, resulting in surplus energy that cannot be exported due to inverter operating limitations. Therefore, the integration of a Battery Energy Storage System is recommended to improve energy utilization. From techno-economic assessment shows the feasibility of the proposed project, with an initial investment cost of USD 38,704, a Net Present Value (NPV) of USD 4,077, an Internal Rate of Return (IRR) of 11.54%, and a payback period of 7 years.
IMPLEMENTASI OTOMASI AC RUANG KELAS BERBASIS JADWAL KULIAH MENGGUNAKAN INTERNET OF THINGS DAN ALGORITMA INTERVAL MERGING Afqilla Regina Putri; Sahirul Alam
Elektrika Borneo Vol 12, No 2 (2026): Elektrika Borneo Edisi Oktober
Publisher : Jurusan Teknik Elektro, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/eb.v12i2.7569

Abstract

Penggunaan AC pada ruang kelas kampus sering kali tidak efisien karena unit AC dibiarkan menyala meskipun ruangan tidak digunakan, sehingga menyebabkan pemborosan energi listrik. Penelitian ini merancang dan mengimplementasikan sistem kontrol dan monitoring AC ruang kelas berbasis IoT dengan penjadwalan otomatis melalui web dashboard, yang mengintegrasikan RESTful API berbasis PHP yang dilayani Nginx, dashboard Vanilla JavaScript, node ESP8266 dengan sensor DHT11 dan actuator inframerah, serta node wattmeter ESP32 independen dengan sensor SCT-013 dan ZMPT101B. Kontribusi utama penelitian ini adalah algoritma penggabungan jadwal (interval merging) yang dijalankan melalui otomasi berbasis cron job, sehingga jadwal kuliah yang tumpang tindih digabungkan untuk mencegah short cycling tanpa menghilangkan kendali manual. Evaluasi mencakup pengujian fungsional, performa backend (TTFB dan throughput) pada delapan endpoint RESTful API, serta dampak efisiensi energi. Seluruh skenario fungsional berhasil (100%), rata-rata TTFB berkisar 8,38-27,21 ms, rata-rata throughput berkisar 7,47-274,59 kbps, dan otomasi penjadwalan menurunkan konsumsi energi harian AC dari 39,6 kWh menjadi 27,0 kWh, atau efisiensi sebesar 32,2%.

Page 11 of 14 | Total Record : 136