cover
Contact Name
Rizki Noor Prasetyono
Contact Email
jeepa@peradaban.ac.id
Phone
+6285713747823
Journal Mail Official
jeepa@peradaban.ac.id
Editorial Address
Prodi Teknik Elektro Fakultas Sains dan Teknologi Universitas Peradaban Jl. Raya Pagojengan KM 3 Paguyangan, Kab. Brebes, Jawa Tengah, Indonesia 52276
Location
Kab. brebes,
Jawa tengah
INDONESIA
Journal of Electronic and Electrical Power Application
Published by Universitas Peradaban
ISSN : 28292898     EISSN : 28084306     DOI : -
Journal of Electronic and Electrical Power Application (JEEPA) diterbitkan oleh program studi teknik elektro Universitas Peradaban bertujuan membantu mempublikasikan hasil penelitian bidang teknik elektro yaitu : Ketenagalistrikan : pembangit/sumber listrik, transmisi tenaga listrik, distribusi tenaga listrik, analisis daya dan hubungan singkat, system proteksi tenaga listrik, mesin-mesin listrik, converter, inverter, pengendalian tenaga listrik, simulasi system tenaga listrik. Elektronika : semionduktor dan rangkaian terpadu (IC), analisis rangkaian elektronika, mikroprosesor, mkrokontroler, sensor, akuator, analisis rangkaian digital. Teknik kendali/kontrol : system otomasi, robotika, system pengaturan cerdas, system tertanam berbasis Internet of thing (IOT), mekatronika.
Articles 47 Documents
IMPLEMENTATION OF MOTORCYCLE SECURITY EQUIPMENT USING RFID BASED ARDUINO UNO E-KTP Ahdika Dafiq Mafaja Yoni; Nasrulloh Nasrulloh; Edmund Ucok Armin
Journal of Electronic and Electrical Power Applications Vol. 2 No. 1 (2022): JEEPA Volume 2 Nomor 1
Publisher : Program Studi Teknik Elektro Universitas Peradaban

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1348.602 KB) | DOI: 10.58436/jeepa.v2i1.1041

Abstract

During a pandemic like now, many workers are being expelled by the company, resulting in a decline in the economy in various regions. To meet the needs of a person may do bad things such as curanmor (motorcycle theft). Even though the motorbike is equipped with a fairly strict security system, it is still sometimes broken by thieves. This study aims to create a motor vehicle security system based on Arduino R3 and RFID as an e-KTP sensor. Where this system can turn on or turn off the motorbike using an ID card or using its RFID Pin. even though the thief managed to break into the ignition, the motor still couldn't start because it needed other access. Based on the results of observations and tests carried out, the authors can conclude that the performance of the motorcycle safety device system using e-KTP works quite well. When the contact is on, it will activate the safety device system before activating the motor electrical system. RFID needs access to the appropriate e-KTP and is forwarded to the microcontroller (Arduino) then produces output to the relay to turn on the motor's electricity so that the motor can be turned on/started
MODELING THE CONTROL PANEL CIRCUIT FOR NICE 3000 ELEVATOR 5 FLOORS USING ELECTRICAL CONTROL TECHNIQUES SIMULATOR SOFTWARE Mohammad Zidan Alfariki; Rizky Mubarok
Journal of Electronic and Electrical Power Applications Vol. 2 No. 1 (2022): JEEPA Volume 2 Nomor 1
Publisher : Program Studi Teknik Elektro Universitas Peradaban

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (360.798 KB) | DOI: 10.58436/jeepa.v2i1.1042

Abstract

Elevator or is one of the tools that serves to facilitate human activities whose routines are more often in a storied room. The existence of this elevator is a substitute for the function of the stairs in reaching each subsequent floor in a multi-storey building. This study simulates a 5-floor elevator control circuit using electrical control techniques simulator software. The use of this application is very helpful for simulating control circuits before the equipment is installed and assembled. Useful for minimizing failures and troubleshooting of the circuit. Based on the results and discussion of the research, there are three main circuits in the control circuit, the new contact circuit and the power circuit. The connection of the power circuit to the motor between the UP contactor and DOWN contactor is not the same. UP contactor connection and motor (R and U), ( V and T ), (T and W). While DOWN contactor and motor (T and U), (V and R), (R and W). This circuit is commonly called an interlock circuit in which the two auxiliary contacts are locked between the auxiliary contact (R. NC) and the auxiliary contact (F.NC) which ensures that they cannot work simultaneously. The process of the elevator going up (UP) has been successful and shows a simulation of the lit going up and without any errors. And the elevator down (DOWN) process has been successful and shows the simulation of the lit going up and up without any errors
ANALISIS PENGARUH PEMASANGAN GROUND ROOT PARALEL PADA NILAI TAHANAN PENTANAHAN JARINGAN DISTRIBUSI 20 KV PT. PLN (PERSERO) ULP BUMIAYU Isnu Gita Kumara; Rizki Noor Prasetyono; Randi Adzind Murdiantoro
Journal of Electronic and Electrical Power Applications Vol. 2 No. 2 (2022): JEEPA Volume 2 Nomor 2
Publisher : Program Studi Teknik Elektro Universitas Peradaban

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58436/jeepa.v2i2.1194

Abstract

The grounding system is an direct protection against instrumentality that uses electricity as a source of power from overcurrent and leakage current or usually caused by lightning. Measurement of the value of grounding resistance is carried out every 6 months to maintan the resistance value of the grounding system to meet PUIL standards. For the grounding system theat has a resistance value above 5 Ohm, it is necessary to add a ground root that is connected in parallel. The resistance value data before and after the addition of the gorund root will then be carried out a simple linear regression analysis using software SPSS 25.0 for windows. The analysis method used in this study is quantitative analysis method to find out whether or not the effect of additional ground root on the grounding resistance. Based on the output model coefficient on SPSS, it showed a significance value of less than 0.05 which means the addition of a parallel ground root had an effect on the value of grounding risistance or could improve the grounding resistance. The output of summary model showed a correlation value (R) of 0.639, which means that the independent variable and the dependent variable had a strong relationship, while the value of R Square or the percentage of the effect of adding ground root to the value of grounding resistance was 40,9% while the other59,1% was influenced by other unexamined factor.
RANCANG BANGUN PENGENDALI PERALATAN ELEKTRONIK DENGAN KENDALI SUARA MENGGUNAKAN TEKNOLOGI INTERNET OF THINGS BERBASIS NODEMCU Amelia Damayanti; Dody Wahjudi; Tri Watininggsih; Isra' Nuur Darmawan
Journal of Electronic and Electrical Power Applications Vol. 2 No. 2 (2022): JEEPA Volume 2 Nomor 2
Publisher : Program Studi Teknik Elektro Universitas Peradaban

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58436/jeepa.v2i2.1256

Abstract

Controlling electronic equipment at home is generally done manually, but with the development of technology in today's modern era, there are many innovations that give rise to various ways of controlling electronic equipment, for example by remote control using IoT technology, using smartphone applications , or by remote control. This research aims to create a modern electronic equipment control system using voice commands with Google Assistant and Blynk. This control system uses an application as a sender, using both Iot media and voice control, namely the Google assistant. These components are assembled into one and made a prototype with the aim of facilitating testing before being attached to the actual installation. After testing the hardware and software. The result is that the response speed after sending data from the two media has different timeframes, IoT media has a response that depends on the internet network used with an average turning on the lights and fans is 0.7 seconds, while using the Google assistant is 4.5 seconds. The system works well if it has good network quality. The use of voice control has a pronunciation limit of 5 commands and uses English. The control system when it is first turned on is not directly connected to the internet, so the user must turn on the hotspot first so that the system can be connected and can run.
IMPLEMENTATION OF LINIER REGRESSIONUSING THE JSN-SR04T SENSOR FOR THE MONITORING WATER LEVEL IN WATER TANKS THROUGH ANTARES PLATFORM Garnis Hasna Iftinan Apsari; Sigit Pramono; Nur Afifah Zen
Journal of Electronic and Electrical Power Applications Vol. 2 No. 2 (2022): JEEPA Volume 2 Nomor 2
Publisher : Program Studi Teknik Elektro Universitas Peradaban

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58436/jeepa.v2i2.1277

Abstract

Its use as a water storage location means that it is not uncommon for the water tank to overflow if the water level exceeds the maximum limit. One of the airtight ultrasonic sensors is the JSN-SR04T ultrasonic sensor for measuring water levels. However, this sensor has a weakness in the measurement reading that is less accurate. One way to improve the accuracy of this sensor's reading is to use the Linear Regression method. The purpose of this research is to test the accuracy of sensor measurement and the effect of linear regression implementation. The platform used in this research is Antares which is used for storing measurement data results. The results of the sensor measurement test show that the sensor is less accurate in measurement, after being implemented with the linear regression method the measurement results are approaching accurate but there is still a slight difference. The linear regression method is able to improve the accuracy of measurement data results better than before using linear regression.
WATER TURBIDITY MONITORING SYSTEM AND RICE FIELD IRRIGATION DISCHARGE DOOR CONTROL USING BLYNK Dzakiya Nur Yuniar; Fikra Titan Syifa; Nur Afifah Zen
Journal of Electronic and Electrical Power Applications Vol. 2 No. 2 (2022): JEEPA Volume 2 Nomor 2
Publisher : Program Studi Teknik Elektro Universitas Peradaban

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58436/jeepa.v2i2.1278

Abstract

The research objective is to design an IoT-based rice field irrigation turbidity monitoring system, where later farmers can monitor water turbidity and control the Internet of Things (IoT) through Turbidity sensor processing and the ESP8266 module produced by Relay and cloud Blynk processing. The research flow starts from a literature search, the software design process compiles program scripts for each component that has been programmed through the Arduino IDE application, then creates Blynk which is used to monitor or monitoring the turbidity of irrigation water in real time. After designing the hardware and software, the next stage is system testing, if there are constraints and the results are not appropriate, then the hardware and software design is carried out again until the test is successful and the data results are appropriate, then proceed to the next stage of making the test data results. The research results of the Water Turbidity Monitoring System and Rice Irrigation Ditch Control Using Blynk have been successfully designed and functioning properly. The turbidity sensor works well with sensor readings that pass the range of 10 to 70. If the sensor value is less than 10, the water is detected as clean, but the value is more than 70, then the water is detected as cloudy or dirty. Findings Quality of service (QoS) research shows unsatisfactory or poor results in the delay, packet loss, and throughput components, which are caused by poor internet connectivity.
IMPLEMENTATION OF MOVING AVERAGE FILTER FOR THE MONITORING WATER LEVEL IN WATER TANKS USING ANTARES. Raffi Noval Pambudi; Slamet Indriyanto; Sigit Pramono
Journal of Electronic and Electrical Power Applications Vol. 2 No. 2 (2022): JEEPA Volume 2 Nomor 2
Publisher : Program Studi Teknik Elektro Universitas Peradaban

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58436/jeepa.v2i2.1279

Abstract

Almost all monitoring systems for measuring the height of water reservoirs use ultrasonic sensors. One of the ultrasonic sensors that is already waterproof is the JSN-SR04T ultrasonic sensor. However, this sensor has a weakness, namely the high error rate of sensor readings, thereby reducing the accuracy of sensor readings. One way to reduce errors that occur in sensors is to implement a Moving Average Filter (MAF) data filter. The MAF used in this study are MAF 5 and MAF 10. The purpose of this study is to test the sensor by comparing the sensor error value if not using MAF by using MAF 5 and MAF 10. For the monitoring system and the database of sensor measurement results used in this study is to use the Antares platform. The test results of the JSN-SR04T ultrasonic sensor reading value state that if the sensor does not use MAF, the sensor reading value produces an average error of 5.41%. Then if the sensor uses MAF 5 produces an average error of 3.42% and MAF 10 produces an average error of 5.21%. These results prove that the implementation of the Moving Average Filter is able to reduce the JSN-SR04T ultrasonic sensor reading error.
FAILBACK FAULT ANALYSIS ON BSG 9 TYPE ELECTRIC WESEL AT PURWOKERTO STATION Dezan Claudio; Randi Adzin Murdiantoro
Journal of Electronic and Electrical Power Applications Vol. 2 No. 2 (2022): JEEPA Volume 2 Nomor 2
Publisher : Program Studi Teknik Elektro Universitas Peradaban

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58436/jeepa.v2i2.1289

Abstract

Wesel (point machine) for the external equipment in the railway system that is used to move the line from a straight back position or vice versa. In the use of electric Wesel lines, there is a driving motor called a point machine. In addition, wesel also require periodic maintenance, self-laser treatment using a period of 2 weeks. Used is descriptive quantitative by presenting data on the evaluation of electric point of view in the field without any engineering or other treatment to obtain data. There is data on the percentage of the physical condition of note 53 with a yield percentage of 87.0% and a failure percentage of 8.7%. And the cumulative percentage of success is 95.7% and the cumulative percentage of failure is 8.7%. In table 5.5 there is data on the percentage of the physical condition of point 23 with a yield percentage of 87.0% and a failure percentage of 8.7%. And the cumulative percentage of success is 95.7% and the cumulative percentage of failure is 8.7%.
Sistem Pemantauan Parameter Kelistrikan berbasis Komunikasi LoRaWAN dengan Platform Antares Fredre Nico Panggabean; Sigit Pramono; Anjar Taufik Hidayat
Journal of Electronic and Electrical Power Applications Vol. 3 No. 1 (2023): JEEPA Volume 3 Nomor 1
Publisher : Program Studi Teknik Elektro Universitas Peradaban

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58436/jeepa.v3i1.1427

Abstract

Electrical power is an important parameter to determine how much electrical energy is consumed or produced. Some systems that consume or generate electricity are located in remote or difficult-to-reach locations, for example monitoring volcanoes or micro-hydro power plants at the mountains. Therefore, we need a tool to monitor the electric power from afar. In this research a tool has been designed that can monitor electrical energy with the PZEM004T-10A sensor in real time using the LoRaWAN network on the Antares platform. From the results of system testing, it can be concluded that the designed system can run well according to its function. The results of the average percentage error reading of the PZEM004T sensor against the power meter measuring instrument show a very good value where the average error obtained in the voltage parameter is 0.45%, while the error value obtained for the current parameter is 0.22%, power is 1.44% and power factor of 0.15%. The performance of the Quality of Service delay value on the network according to the standard criteria issued by TIPHON, the delay value produced by SF7 and SF10 is categorized as a bad delay. Then the delay on SF9 and SF12 is included in the good category, and the delay produced by SF8 and SF11 is categorized as a very good delay. Meanwhile, the packet loss value is included in the very good criteria for SF8-SF12 and good for SF 7.
ANALYSIS OF SPINNING RESERVE SETTINGS AGAINST ANTICIPATION OF BLACK OUT AND TOTAL FUEL USE AT POWER HOUSE DIVISION Jhon Hericson Purba; Elsa Gultom
Journal of Electronic and Electrical Power Applications Vol. 3 No. 1 (2023): JEEPA Volume 3 Nomor 1
Publisher : Program Studi Teknik Elektro Universitas Peradaban

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58436/jeepa.v3i1.1441

Abstract

One of the biggest users of electrical energy in Batam City is the Batamindo Industrial Park area, so that area is required to have an electricity provider managed by the Batamindo Power House Division. To anticipate generation problems such as fuel gas trips in the power generation system, generation failures such as power disruption or even total blackouts, Power House Batamindo has a big responsibility. Power House Batamindo makes maximum and minimum power reserve limits. However, this can result in a large use of fuel for power generation and will also increase the cost of electricity production. In a converted generator engine, it will produce more power if it uses diesel fuel rather than gas. The results of research conducted for one month and data analysis carried out, as much as 84.7% of the installed spinning reserves are at 10-14 MW and as much as 5.1% are below the limit of the provision for spinning reserves (10-14 MW) which must be suppressed the numbers. The results of the research also prove that to prevent high diesel fuel emissions in generator engines, it is necessary to save diesel fuel by avoiding generation problems, one of which is paying the spinning reserve limit.