cover
Contact Name
T Mohd Yoshandi
Contact Email
tm.yoshandi@gmail.com
Phone
+6281275127980
Journal Mail Official
tm.yoshandi@gmail.com
Editorial Address
Jl. Karya Bakti, No. 8 Simp. BPG, Kel. Bambu Kuning, Kec. Tenayan Raya
Location
Kota pekanbaru,
Riau
INDONESIA
Medical Imaging and Radiation Protection Research (MIROR) Journal
ISSN : -     EISSN : 28085272     DOI : https://doi.org/10.54973/miror
Core Subject : Health, Science,
Medical Imaging and Radiation Protection Research (MIROR) Journal is a peer-reviewed publication and archiving fundamental, translational as well as aplication in research of focused in Medical Imaging, Radiation Protection, Safety, and Nuclear Medicine.
Articles 5 Documents
Search results for , issue "Vol 2 No 1 (2022): Medical Imaging and Radiation Protection Research Journal" : 5 Documents clear
PENATALAKSANAAN APPENDICOGRAM DENGAN KLINIS APENDISITIS DI INSTALASI RADIOLOGI RSUD ARIFIN ACHMAD PROVINSI RIAU Shelly Angella; Agus Salim; Saidatia Hawari
Medical Imaging and Radiation Protection Research Journal Vol 2 No 1 (2022): Medical Imaging and Radiation Protection Research Journal
Publisher : LPPM STIKes Awal Bros Pekanbaru

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (252.516 KB) | DOI: 10.54973/miror.v2i1.79

Abstract

Appendicogram is the barium appendix examination in the form of photo that can help to see blockages or dirt in the appendix. The purpose of this study was to find  the Appendicogram examination management with clinical appendicitis in the Radiology Installation of Arifin Achmad Hospital,  Riau Province, to find out why there were differences in appendicogram examination techniques between the theory and the Arifin Achmad Regional Hospital in Riau Province and to see the Appendicogram radiograph results with eight hours waiting time. This research is qualitative with a descriptive research design and a study case approach. The subjects used were 3 radiologists, 1 sending doctor, and 3 radiographers. The object of the study was 2 patients who had undergone an appendicogram examination with appendicitis clinical at Arifin Achmad Hospital, Riau Province. The results showed that the appendicogram examination did not need specific preparation. The patient was not subjected to plain radiographic before given contrast because plain radiographs on the appendicogram because it did not give any information. The patient was given a contrast of 50gr of barium sulfate mixed with 250ml of water. Post contrast photo 8 hours later, the reason for using 8 hours is because normal human peristalsis ranges from 6-8 hours. The results of the radiographic are visualized, namely, the contrast journey to the appendix is ​​smooth, there is no visible pressure on the cecum, the appendix is ​​not filled with contrast.  
A WORKLOAD ANALYSIS USING POWER RADIOGRAPHER WORKLOAD INDICATORS NEED STAFF (WISN) IN THE INSTALLATION OF RADIOLOGY UNIVERSITY HOSPITAL SEBELAS MARET SURAKARTA: Analisa Tanggung Jawab Radiografer Menggunakan Metode Workload Indicator Staffing Needs (WISN) Siti Arifah
Medical Imaging and Radiation Protection Research Journal Vol 2 No 1 (2022): Medical Imaging and Radiation Protection Research Journal
Publisher : LPPM STIKes Awal Bros Pekanbaru

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (270.472 KB) | DOI: 10.54973/miror.v2i1.203

Abstract

Analisis tanggung jawab radiografer Sangat penting untuk mengembangkan lebih lanjut manfaat radiologi di klinik darurat. Hal ini dimaksudkan untuk mengetahui pekerjaan mana yang membutuhkan produktivitas. Workload indicators of staffing need (WISN) merupakan sebuah standar pengukuran  kebutuhan tenaga Kesehatan berdasarkan  indikator  beban kerja  Strategi ini adalah teknik komputasi yang membuat garis besar tanggung jawab seperti halnya jumlah kebutuhan aset manusia yang bergantung pada latihan item di kelas. sumber daya manusia. Penelitian ini untuk mengetahui gambaran beban kerja petugas radiografer menggunakan metode WISN. Observasi ini menggunakan pendekatan kuantitatif deskriptif dengan pendekatan survey. Di Instalasi Radiologi RS UNS jumlah waktu kerja tersedia dari kegiatan kerja setiap hari dan jumlah hari libur dalam setahun 120 menit per tahun dimana jumlah waktu kerja yang tersedia yang didapatkan sudah sesuai sesuai dengan standar waktu kerja di Rumah Sakit UNS. Beban kerja yang didaptkan 260 hari per tahun dan rata-rata waktu yang dibutuhkan untuk menangani pasien 5-10 menit untuk pasien konven dan Ct-Scan dan untuk kontras 30-1 jam tergantung pemeriksaan dan waktu kerja dalam sehari 7-8 jam. Standar beban kerja 2000 jam per tahun dan untuk menentukan standar kelonggaran 75(1 jam 15 menit per orang) dan untuk memastikan SDM per unit kerja 2,25. hasil yang diperoleh melalui metode workload indicators staffing needs (WISN) sudah sesuai dengan standar pelayanan radiologi diagnostik menurut Kepmenkes No. 1014 Tahun 2008 yang menerangkan bahwa perbandingan 1 modalitas pesawat diagnostik untuk 2 orang radiografer.
ANALYSIS OF THE SCATTERING FROM CONVENTIONAL X-RAY IN THE RADIOLOGY INSTALLATION OF ZAINAB HOSPITAL Yoki Rahmat; Riri Melani Gustia; Agus Salim
Medical Imaging and Radiation Protection Research Journal Vol 2 No 1 (2022): Medical Imaging and Radiation Protection Research Journal
Publisher : LPPM STIKes Awal Bros Pekanbaru

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (205.535 KB) | DOI: 10.54973/miror.v2i1.206

Abstract

Radiation consists of primary radiation and scattered radiation. Primary radiation is radiation that comes out of the X-ray tube, radiation that comes out of the object and is not in the same direction as the primary beam is called scattering radiation. This scattering radiation will increase the amount of radiation dose received. The closer our bodies to the radiation source, the greater the radiation exposure we receive. Based on the principle of external radiation protection to prevent exposure to radiation we can maintain a safe distance at a safe level and use shielding from radiation sources. This research is a type of descriptive quantitative research with an experimental approach. This research was conducted at RSIA Zainab in June 2021. In this study, an x-ray plane was used as a radiation source, a surveymeter as a scattering radiation detection tool, shielding as a protective device and a meter for distance measurement. Radiation distribution is strongly influenced by distance and the use of shielding, this is in accordance with the inverse square law theory which states that the intensity of light or linear waves emitting from a point source is inversely proportional to the square of the distance from the source or the farther the distance the smaller the radiation exposure, and the use of shielding as a protective barrier at the time of exposure is very effective because x-ray radiation does not penetrate with materials that have a high atomic number such as Pb which is used as a shielding coating.
OVERVIEW OF RADIATION SAFETY MANAGEMENT SYSTEM IN RADIOLOGY FACILITY OF PETALA BUMI REGIONAL GENERAL HOSPITAL T.Mohd Yoshandi; Andre Saputra; Devi Purnamasari
Medical Imaging and Radiation Protection Research Journal Vol 2 No 1 (2022): Medical Imaging and Radiation Protection Research Journal
Publisher : LPPM STIKes Awal Bros Pekanbaru

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (94.123 KB) | DOI: 10.54973/miror.v2i1.208

Abstract

The radiation safety management system consists of seven components that must be implemented, namely radiation protection organization, radiation dose monitoring and radioactivity monitoring, radiation protection equipment, medical checks up, document archiving, quality assurance, and education and training. This study aims to determine whether or not the seven components have been fulfilled. The type of research conducted in this study is descriptive with a qualitative approach. The results show that the radiology facility of Petala Bumi Regional Hospital has fulfilled most of the components.
IN THE CASE OF LOW BACK PAIN LUMBOSACRAL EXAMINATION IN PANDAN ARANG HOSPITAL Dyah Ayu Puspitaningtyas; Silvi Nugraeni; Yuni Purwanti Hastuti
Medical Imaging and Radiation Protection Research Journal Vol 2 No 1 (2022): Medical Imaging and Radiation Protection Research Journal
Publisher : LPPM STIKes Awal Bros Pekanbaru

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (328.82 KB) | DOI: 10.54973/miror.v2i1.209

Abstract

AP (Antero Posterior), Lateral and Oblique are lumbar projection that used in radiology for low back pain. In Pandan Arang Boyolali Hospital, central ray in lateral projection did not use angle for examination. In literature, always used an angle for lateral projection. Aim of this study is to knowing radiology examination of LBP and reason of lateral projection without angle. This research is used case study with data collection from observation, study literature and interview. Based on results, lumbar examination in Pandan Arang Boyolali Hospital used AP, Oblique and Lateral with perpendicular for central ray. Purpose lateral projection without angle is does required an angle because patient pelvic and thorax is not too wide.

Page 1 of 1 | Total Record : 5