cover
Contact Name
Yunita Djamalu
Contact Email
naurainezia23@gmail.com
Phone
+6281244439447
Journal Mail Official
ijree.ppv@gmail.com
Editorial Address
Kampus 2 Sekolah Vokasi UNG, Jalan Drs. Achmad Nadjamuddin No. 35 (Eks. Jl Raden Saleh) Kel. Limba U2 Kec. Kota Selatan, Kota Gorontalo 96115
Location
Kota gorontalo,
Gorontalo
INDONESIA
Journal Of Renewable Energy Engineering
ISSN : 29861063     EISSN : 2988554X     DOI : 10.56190
Journal Of Renewable Energy Engineering (JREE) is a peer-reviewed journal published twice a year (April and October) by the Vocational Program of the State University of Gorontalo. The Vocational Journal of Science and Technology provides direct open access to its content. The aim of this journal is to provide the expression of ideas, as well as places for knowledge fields that can understand applied science and technology issues and knowledge, with a new space of journals covering the fields of science and technology. applied science and technology research including Mathematics, Physics, Technology, and Informatics
Articles 65 Documents
TINJAUAN LITERATUR STATE OF THE ART MODEL OPTIMASI SPASIAL ENERGI SURYA UNTUK TRANSISI ENERGI BERKELANJUTAN DALAM PERSPEKTIF FILSAFAT SAINS sudarmanto hasan; Hasim; Mahludin Baruwadi; Wenny J A Musa
Journal Of Renewable Energy Engineering Vol. 4 No. 2 (2026): Journal Of Renewable Energy Engineering (Oktober)
Publisher : Program Vokasi-Universitas Negeri Gorontalo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56190/jree.v4i2.116

Abstract

ABSTRACT  Solar energy planning has evolved from mapping resource potential and assessing site suitability to increasingly integrating space, capacity, networks, demand, storage, land use, and energy transition goals. This article reviews 129 English-language Scopus records published during 2020–2026 and retrieved through a structured search on October 5, 2026. After duplicate auditing and title–abstract screening, 119 studies were retained for synthesis, comprising 63 core and 56 supporting studies, while 10 records were excluded. To strengthen consistency, a stratified random re-audit of 26 records (20.2% of the corpus; 13 Core, 11 Supporting, and 2 Exclude) was conducted using the same operational codebook; all 26 records retained their original classification. Because this was an internal consistency check rather than independent dual screening, no inter-rater statistic was calculated. The review also applies an appraisal of information depth available in titles and abstracts and a targeted full-text verification of five key studies used to substantiate the principal research gaps. The synthesis reveals a continuum from potential mapping and GIS–MCDA to spatial decision support, spatial–energy system integration, and more robust transition planning. The ontology–epistemology–axiology lens is used as an interpretive framework rather than as an attribution of explicit philosophical positions to the reviewed studies. Ontologically, the analytical focus shifts from identifying the “best site” to understanding socio-technical territorial energy systems. Epistemologically, approaches advance from overlay and weighting toward optimization, sensitivity analysis, scenarios, and GeoAI. Axiologically, models increasingly address trade-offs among energy production, cost, land, environment, reliability, resilience, and social legitimacy. Five major gaps are identified: suitability-to-deployment, grid–demand integration, land–environment trade-offs, robustness, and spatial–transition linkage. The review proposes a provincial-level integrative framework linking “where,” “how much,” and “with what transition implications,” with direct relevance to model development in Gorontalo Province.   ABSTRAK  Perencanaan energi surya berkembang dari pemetaan sumber daya dan penilaian kesesuaian lokasi mengintegrasikan ruang, kapasitas, jaringan, permintaan, penyimpanan, penggunaan lahan, serta tujuan transisi energi. Artikel ini meninjau 129 rekaman Scopus berbahasa Inggris periode 2020–2026 yang diperoleh melalui strategi pencarian terstruktur pada 5 Oktober 2026. Setelah audit duplikasi dan penyaringan judul–abstrak, 119 studi dipertahankan sebagai basis sintesis, terdiri atas 63 studi Core dan 56 Supporting, sementara 10 rekaman dikeluarkan. Untuk memperkuat konsistensi seleksi, dilakukan audit ulang acak terstratifikasi terhadap 26 rekaman (20,2% korpus; 13 core, 11 supporting, dan 2 exclude) menggunakan codebook operasional yang sama; seluruh 26 rekaman mempertahankan klasifikasi awal. Karena pemeriksaan ini merupakan consistency check internal dan bukan independent dual screening, statistik antar-reviewer tidak dihitung. Tinjauan juga menerapkan penilaian kedalaman informasi yang tersedia pada judul dan abstrak serta verifikasi full-text terarah terhadap Lima studi kunci yang menopang gap utama. Sintesis menunjukkan suatu kontinum perkembangan dari pemetaan potensi dan GIS–MCDA menuju dukungan keputusan spasial, integrasi spasial–sistem energi, hingga perencanaan transisi yang lebih robust. Lensa ontologi–epistemologi–aksiologi digunakan sebagai kerangka interpretatif penulis, bukan sebagai klaim bahwa studi yang ditinjau secara eksplisit menganut posisi filosofis tertentu. Secara ontologis, objek analisis bergeser dari “tapak terbaik” menuju sistem energi teritorial sosio-teknis; secara epistemologis, pembentukan pengetahuan bergerak dari overlay dan pembobotan menuju optimasi, pengujian sensitivitas, skenario, dan GeoAI; secara aksiologis, model semakin menghadapkan trade-off antara produksi energi, biaya, lahan, lingkungan, reliabilitas, ketahanan, dan legitimasi sosial. Sintesis komparatif mengidentifikasi Lima gap utama: suitability-to-deployment, integrasi grid–demand, trade-off lahan–lingkungan, robustness, dan keterhubungan spasial–transisi. Berdasarkan rantai bukti tersebut, artikel mengusulkan kerangka integratif tingkat provinsi untuk menghubungkan pertanyaan “di mana,” “berapa besar,” dan “apa implikasinya terhadap transisi energi,” dengan relevansi langsung bagi pengembangan model di Provinsi Gorontalo.
ANALISIS KELAYAKAN PEMASANGAN PLTS ON-GRID PADA SISTEM KELISTRIKAN KAMPUS 4 UNIVERSITAS NEGERI GORONTALO Abdul Mufli S. Mento; Ervan Hasan Harun; Sardi Salim
Journal Of Renewable Energy Engineering Vol. 4 No. 2 (2026): Journal Of Renewable Energy Engineering (Oktober)
Publisher : Program Vokasi-Universitas Negeri Gorontalo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56190/jree.v4i2.119

Abstract

ABSTRACT  Indonesia’s renewable energy mix remains below target, while changes in rooftop photovoltaic (PV) regulation affect the economic attractiveness of PV investments. This study aimed to design an on-grid rooftop PV system based on the maximum available roof area at Campus 4 of Universitas Negeri Gorontalo and compare its economic feasibility under the 1:1 net metering scheme (Ministerial Regulation of Energy and Mineral Resources No. 26/2021) and the current scheme (No. 2/2024). A descriptive quantitative case study was conducted on 12 buildings of four faculties. Solar radiation was measured with a solar power meter, temperature data were obtained from the meteorological agency (BMKG), roof area was digitized from satellite imagery and validated against as-built drawings, and the string–inverter configuration was verified against voltage and current limits. Economic feasibility over 25 years was assessed using NPV, IRR, payback period, and BCR at a 5.75% discount rate, followed by one-at-a-time sensitivity analysis. The results show a capacity of 2,494.24 kWp (3,808 modules and 29 inverters) producing about 4.08 GWh per year, 10.5 times the campus consumption of 388 MWh per year. Under net metering 1:1, the project is feasible (NPV IDR 8.05 billion, IRR 9.03%, payback 9.34 years, BCR 1.27) and robust to sensitivity. Under Regulation No. 2/2024, only 9.6% of production has economic value, so the project is not feasible (NPV −IDR 25.68 billion, IRR −22.54%, BCR 0.13) in all scenarios. The capacity should be right-sized to about 237 kWp (a preliminary estimate) under the current regulation.   ABSTRAK  Bauran energi terbarukan Indonesia masih berada di bawah target, sementara perubahan regulasi PLTS atap memengaruhi daya tarik investasinya. Penelitian ini bertujuan merancang PLTS atap on-grid berdasarkan potensi maksimum luas atap Kampus 4 Universitas Negeri Gorontalo serta membandingkan kelayakan ekonominya pada skema net metering 1:1 (Permen ESDM No. Twenty six Tahun 2021) dan skema yang berlaku (Permen ESDM No. 2 Tahun 2024). Penelitian menggunakan metode kuantitatif deskriptif dengan studi kasus pada 12 gedung di empat fakultas. Radiasi matahari diukur dengan solar power meter, data suhu diperoleh dari BMKG, luas atap didigitasi dari citra satelit dan divalidasi dengan gambar as built drawing, dan konfigurasi string–inverter diverifikasi terhadap batas tegangan dan arus. Kelayakan ekonomi selama 25 tahun dianalisis dengan NPV, IRR, payback period, dan BCR pada tingkat diskonto 5,75%, dilanjutkan analisis sensitivitas satu variabel. Hasilnya, kapasitas sistem sebesar 2.494,24 kWp (3.808 modul dan 29 inverter) menghasilkan sekitar 4,08 GWh per tahun, atau 10,5 kali konsumsi kampus sebesar 388 MWh per tahun. Pada skema net metering 1:1, proyek layak (NPV Rp8,05 miliar, IRR 9,03%, payback 9,34 tahun, BCR 1,27) dan tahan terhadap perubahan asumsi. Pada Permen ESDM No. 2 Tahun 2024, hanya 9,6% produksi yang bernilai ekonomi sehingga proyek tidak layak (NPV −Rp25,68 miliar, IRR −22,54%, BCR 0,13) pada seluruh skenario. Kapasitas perlu disesuaikan menjadi sekitar 237 kWp (estimasi awal) pada regulasi saat ini.  
ANALISIS KETIDAKSEIMBANGAN BEBAN DAN RUGI DAYA AKIBAT ARUS NETRAL PADA INSTALASI LISTRIK PESANTREN SULAIMANIYAH USMAN TAYEB GORONTALO Qais Mohamad; Arifin Matoka; Ervan Hasan Harun
Journal Of Renewable Energy Engineering Vol. 4 No. 2 (2026): Journal Of Renewable Energy Engineering (Oktober)
Publisher : Program Vokasi-Universitas Negeri Gorontalo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56190/jree.v4i2.120

Abstract

ABSTRACT Load imbalance among the phases of a low-voltage three-phase four-wire installation produces neutral current and additional power loss in the neutral conductor. Boarding-school (pesantren) installations combine dormitory, kitchen, classroom, and prayer-hall loads that operate simultaneously every day, yet phase balance is rarely documented. This study aims to determine the percentage of load imbalance, neutral current, and neutral-conductor power loss of Sub-Distribution Panels (SDPs) 1 and 2 at Pondok Pesantren Sulaimaniyah Usman Tayeb, Gorontalo. A descriptive-analytical quantitative method was applied. Phase and neutral currents were measured with a clamp meter three times a day (morning, afternoon, evening) for seven consecutive days, 18–24 May 2026, giving 21 measurements per panel. Imbalance was calculated using the phase-coefficient method and compared with the 20% limit of IEEE Std 446. Neutral loss was calculated from the measured neutral current and actual cable resistance. SDP 1 showed an imbalance of 2.53–17.63% (mean 9.12%), all within the limit, whereas SDP 2 ranged from 2.48% to 21.51% (mean 11.03%), with one measurement above the limit and 13 of 21 above 10%. Mean neutral current was 4.32 A (SDP 1) and 4.57 A (SDP 2). Mean neutral loss was 0.79 W and 2.13 W, respectively. The 2.7-fold loss difference stems mainly from the longer neutral cable of SDP 2 (50 m versus 20 m). Imbalance appears to be governed by the simultaneous operating pattern of loads rather than by installed capacity. Redistribution of loads among phases, starting with SDP 2, is recommended.   ABSTRAK Ketidakseimbangan beban antar fasa pada instalasi tegangan rendah tiga fasa empat kawat menimbulkan arus netral dan rugi daya tambahan pada penghantar netral. Instalasi pesantren menggabungkan beban asrama, dapur, ruang belajar, dan tempat ibadah yang beroperasi serentak setiap hari, tetapi keseimbangan fasanya jarang didokumentasikan. Penelitian ini bertujuan menghitung persentase ketidakseimbangan beban, arus netral, dan rugi daya pada penghantar netral Sub Distribution Panel (SDP) 1 dan SDP 2 di Pondok Pesantren Sulaimaniyah Usman Tayeb Gorontalo. Metode yang digunakan adalah kuantitatif deskriptif analitik. Arus fasa dan arus netral diukur dengan clamp meter tiga kali sehari (pagi, siang, malam) selama tujuh hari berturut-turut pada 18–24 Mei 2026, sehingga diperoleh 21 titik ukur per panel. Ketidakseimbangan dihitung dengan metode koefisien fasa dan dibandingkan dengan batas 20% menurut IEEE Std 446, sedangkan rugi netral dihitung dari arus netral terukur dan resistansi kabel aktual. SDP 1 menunjukkan ketidakseimbangan 2,53–17,63% (rata-rata 9,12%) dan seluruhnya di bawah batas, sedangkan SDP 2 berkisar 2,48–21,51% (rata-rata 11,03%) dengan satu titik ukur melampaui batas dan 13 dari 21 titik di atas 10%. Arus netral rata-rata adalah 4,32 A (SDP 1) dan 4,57 A (SDP 2), dengan rugi netral rata-rata 0,79 W dan 2,13 W. Selisih rugi 2,7 kali terutama disebabkan kabel netral SDP 2 yang lebih panjang (50 m berbanding 20 m). Ketidakseimbangan tampak lebih ditentukan oleh pola pengoperasian beban yang serentak daripada kapasitas terpasang. Redistribusi beban antar fasa, dimulai dari SDP 2, direkomendasikan.
STUDI KELAYAKAN TEKNIS DAN EKONOMI PEMANFAATAN SEL SURYA SEBAGAI SUMBER ENERGI DI RUMAH TANGGA Rahman Ishak; Ervan Hasan Harun; Taufiq Ismail Yusuf
Journal Of Renewable Energy Engineering Vol. 4 No. 2 (2026): Journal Of Renewable Energy Engineering (Oktober)
Publisher : Program Vokasi-Universitas Negeri Gorontalo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56190/jree.v4i2.121

Abstract

The utilization of solar energy through photovoltaic (PV) systems is an alternative for household electricity supply that needs to be assessed based on electricity consumption and local resource conditions. This study aims to determine the PV system capacity based on the actual electricity consumption of PLN customers and to evaluate its technical and economic feasibility in Biau District, North Gorontalo Regency. A descriptive quantitative method was applied to 10 PLN customers with 1,300 VA and 2,200 VA capacities. The results show PV system capacities of 1.7–5.0 kWp with annual energy production of 2,561.42–7,533.60 kWh and a Cover Ratio (CR) of 86–100%. The Performance Ratio (PR) of 80%, Capacity Factor (CF) of 17.20%, and Specific Yield (SY) of 1,506.72 kWh/kWp/year are derived parameters based on the design assumption. The economic analysis resulted in positive NPV values, an IRR of 12–14%, and a Payback Period (PP) of 6–8 years. The base-case LCOE of IDR 1,160.84/kWh is lower than the PLN electricity tariff of IDR 1,444.70/kWh. Sensitivity analysis shows that a ±10% change in solar radiation or PR results in an LCOE of approximately IDR 1,055–1,290/kWh, while a ±10% change in CAPEX results in an LCOE of approximately IDR 1,045–1,277/kWh. The findings indicate that actual-consumption-based PV utilization should consider performance and cost assumptions through sensitivity analysis.
EKOLOGI PESISIR DALAM TRANSISI ENERGI TERBARUKAN: TANTANGAN DAN PELUANG INTEGRASI DALAM PERENCANAAN SPASIAL LAUT sudarmanto hasan; Dewi Wahyuni K. Baderan; Hasim
Journal Of Renewable Energy Engineering Vol. 4 No. 2 (2026): Journal Of Renewable Energy Engineering (Oktober)
Publisher : Program Vokasi-Universitas Negeri Gorontalo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56190/jree.v4i2.122

Abstract

ABSTRACT  The transition to marine renewable energy involves not only electricity generation potential but also spatial demands and coastal ecosystem protection. Energy infrastructure, including turbine foundations, submarine cables, cable landfalls, and supporting activities, may exert environmental pressures on interconnected mangrove, seagrass, and coral reef ecosystems. This study examines the integration of coastal ecological functions into marine renewable energy spatial planning and proposes a decision-making framework for future empirical evaluation. A structured literature review was conducted using 90 unique Scopus records retrieved through three search groups. Title and abstract screening identified 26 core studies, 43 supporting studies, and 21 excluded records. The thematic synthesis indicates that existing research predominantly addresses spatial-use conflicts, ecosystem modeling, and cumulative environmental impacts, while direct evidence linking tropical coastal habitat connectivity with renewable energy infrastructure siting remains limited within the reviewed corpus. Based on these findings, a six-stage planning framework is proposed, incorporating minimum indicators for planning objectives and spatial boundaries, habitat distribution and condition, sensitive areas and infrastructure corridors, ecological exposure characteristics, alternative site comparison and cumulative impacts, and environmental changes for adaptive monitoring. The framework provides a conceptual approach to incorporating ecological considerations into renewable energy spatial decisions. However, its operational effectiveness requires further empirical testing and validation using site-specific spatial datasets and ecological conditions. ABSTRAK  Transisi energi terbarukan di kawasan laut tidak hanya berkaitan dengan potensi pembangkitan listrik, tetapi juga dengan kebutuhan ruang dan perlindungan ekosistem pesisir. Infrastruktur energi, seperti fondasi turbin, jalur kabel bawah laut, fasilitas pendaratan kabel, dan aktivitas pendukung, berpotensi menimbulkan tekanan terhadap ekosistem mangrove, padang lamun, dan terumbu karang yang saling terhubung. Penelitian ini bertujuan menganalisis integrasi fungsi ekologis pesisir dalam perencanaan spasial energi terbarukan laut serta merumuskan kerangka keputusan yang dapat diuji pada penelitian berikutnya. Kajian dilakukan melalui tinjauan literatur terstruktur terhadap 90 artikel unik dari Scopus yang diperoleh melalui tiga kelompok pencarian. Hasil penyaringan judul dan abstrak mengidentifikasi 26 artikel inti, 43 artikel pendukung, dan 21 artikel yang dikeluarkan. Sintesis tematik menunjukkan bahwa penelitian terdahulu lebih banyak membahas konflik pemanfaatan ruang, pemodelan ekosistem, dan dampak kumulatif, sedangkan keterkaitan langsung antara konektivitas ekosistem pesisir tropis dan penentuan lokasi infrastruktur energi masih terbatas dalam basis data yang dianalisis. Berdasarkan temuan tersebut, diusulkan kerangka perencanaan enam tahap dengan indikator minimum yang mencakup tujuan dan batas wilayah, sebaran serta kondisi habitat, kawasan sensitif dan koridor infrastruktur, karakteristik paparan ekologis, perbandingan alternatif lokasi dan dampak kumulatif, serta perubahan kondisi lingkungan untuk pemantauan adaptif. Kerangka ini menawarkan pendekatan konseptual untuk mengintegrasikan pertimbangan ekologis ke dalam keputusan spasial energi terbarukan. Namun, penerapannya masih memerlukan pengujian empiris dan validasi menggunakan data spasial serta kondisi ekologis setempat.