RANCANG BANGUN SISTEM PENGENALAN POLA SIDIK JARI MENGGUNAKAN METODE MINUTIAE Sudartono, -; Susilo, Sunarno
Jurnal Pendidikan Fisika Indonesia Vol 7, No 1 (2011)
Publisher : Jurusan Fisika, Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Negeri Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Penelitian ini bertujuan merancang sistem pengenalan pola sidik jari menggunakan metode minutiae sehingga dihasilkan sistempengenalan pola sidik jari menjadi lebih akurat. Dalam penelitian ini, dilakukan operasi pengolahan citra yang meliputi PerbaikanCitra (Image Enhancement), Binerisasi, Image Segmentation, Minutia Extraction, Pencocokan citra sidik jari. Hasil penelitianmenunjukkan bahwa minutiae dapat digunakan untuk merancang sistem pengenalan pola sidik jari. Hal ini dapat dibuktikandengan cukup tingginya nilai pencocokan (match) untuk citra sidik jari yang sama yaitu diatas 30%, sedangkan untuk citra sidik jariyang berbeda nilai pencocokan (match) sangat kecil yaitu dibawah 30%. The goal of this research is to design an accurate system of finger print pattern recognition using a minutiae method. There areseveral operations performed in this research, those are image processing, consisting of image enhancement, binary processing,Image Segmentation and Minutia Extraction, and finger print image recognition. The result shows that minutiae method can beused to design a system of finger print recognition, proven by the high value of match recognition for similar finger print image, that isabove 30% and those for different finger print image which is only below 30%.Keywords: Image; Minutiae; finger print
Rancang Bangun Sistem Penangkap Gambar Radiograf Digital Berbasis Kamera DSLR -, Susilo; -, Supriyadi; -, Sutikno; -, Sunarno; Setiawan, R.
Jurnal Pendidikan Fisika Indonesia Vol 10, No 1 (2014): January 2014
Publisher : Physics Department, Faculty of Mathematics and Natural Sciences, Semarang State University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/jpfi.v10i1.3052

Abstract

Telah dilakukan modifikasi sistem penangkap gambar kedap cahaya yang dapat menampilkan langsung citra radiograf digital pada layar monitor PC dan menyimpan file radiograf tersebut sehingga bisa ditampilkan kembali. Penelitian ini bertujuan membangun model prototip sistem penangkap gambar berbasis kamera digital, sehingga hasilnya bisa diproses lebih lanjut menggunakan perangkat lunak pengolah citra berbasis Matlab. Hasil pemotretan dengan sinar-X pada benda uji dan volunteer digunakan untuk menguji keajegan hasil radiograf tersebut, dan diperoleh perbaikan kontras yang signifikan, ditunjukkan dengan tampilan histogram, nilai MSE dan PSNR yang sesuai. Aplikasi perangkat lunak tersebut dalam menganalisis radiograf benda uji, kaki, tangan serta stepwedge menunjukkan juga kenaikan ukuran file, kontras radiograf dan resolusi citra yang meningkat. Hasil ini menunjukkan bahwa model penangkap gambar yang dilengkapi dengan perangkat lunak berbasis Matlab dapat dikembangkan untuk pemeriksaan radiografi digital yang efektif, efisien dan mempunyai nilai ekonomi yang tinggi. It has been modified a system of light-tight image capturing which can display directly digital radiograph image on the monitor screen of PC and save that radiograph digital image for re-displaying it. This research aims to build a prototype of digital camera based-image capturing, so that the result can be processed further using a mathlab based-image processing software. The imaging process using X-ray on the test materials and volunteers are used to investigate its image consistency and find more contrast image, shown on the histogram, appropriate MSE and PSNR values. The application of this software for analyzing test materials, feet, hands and stepwdge showed the file size increase, radiograph constrast, and image resolution. This result shows that a model of image capturing completed by software based-mathlab can be developed to check an effective, efficient and has an economic value digital radiography test result.
UJI KOLIMATOR PADA PESAWAT SINAR-X MERK/ TYPE MEDNIF/SF-100BY DI LABORATORIUM FISIKA MEDIK MENGGUNAKAN UNIT RMI Martina, D; Susilo, Susilo; Sunarno, Sunarno
Jurnal MIPA Vol 38, No 2 (2015): October 2015
Publisher : Jurnal MIPA

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Pengujian kolimator merupakan salah satu program Quality Control (QC) pesawat sinar-X, salah satu pengujian kolimator dengan menggunakan unit RMI. Tujuan pengujian kolimator adalah untuk mengetahui kesesuaian luas lapang kolimator dengan luas lapang berkas sinar-X dalam toleransi ≤ 2% Focus Film Distance (FFD) yang telah ditentukan oleh Keputusan Menteri Kesehatan No. 1250/SK/XII/2009. Penelitian dilakukan menggunakan variasi FFD pada jarak 117cm, 107cm, 97cm, 87cm,  dan  variasi faktor eksposi yang dibedakan pada besar tegangannya (kV). Dalam penelitian ini menggunakan unit radiograf digital (DR), tidak lagi menggunakan radiograf konvesional seperti penelitian-penelitian sebelumnya. Penyimpangan atau ketidaksesuaian luas lapang kolimator dengan luas lapang berkas sinar-X dilakukan dengan cara mengevaluasi batas tegas garis yang dibentuk oleh sumbu X dan sumbu Y, kemudian menentukan titik tengah antara batas tegas garis dan batas radiasi hambur. Hasil penyimpangan disimpulkan bahwa pesawat sinar-X tersebut mengalami penyimpangan melebihi toleransi ≤ 2% FFD yang terjadi pada bagian vertikal.Testing collimator is one program of Quality Control (QC) plane of X-rays, a collimator testing using RMI unit. The purpose of testing is to determine the suitability collimator spacious airy spacious airy collimators with X-ray beam in tolerance ≤ 2% Focus Film Distance (FFD), which have been determined by the Ministry of Health Decree No. 1250 / SK / XII / 2009. Studies have been conducted using variations of FFD is at a distance of 117cm, 107cm, 97cm, 87cm, and a variety of factors that distinguished the great eksposi voltage (kV). What distinguishes this study using digital radiographs unit (DR) is no longer using conventional radiographs as previous studies. Deviations or nonconformance spacious airy spacious airy collimators with X-ray beam is done by evaluating well defined line formed by the X axis and Y axis, and then determine the midpoint between the firm boundaries and boundary lines scatter radiation. The results concluded that the irregularities plane X-rays are experiencing deviations exceed the tolerance ≤ 2% FFD that occurs in the vertical (Y_n).
PEMBUATAN SISTEM PENGATURAN PUTARAN MOTOR DC MENGGUNAKAN KONTROL PROPORTIONAL-INTEGRAL-DERIVATIVE (PID) DENGAN MEMANFAATKAN SENSOR KMZ51 Khakim, L; -, Sunarno; -, Sugiyanto
Jurnal MIPA Vol 35, No 2 (2012): October 2012
Publisher : Jurnal MIPA

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Penelitian ini adalah penelitian pengembangan desain rancang bangun sistem pengendalian otomatis yang digerakkan dengan dua motor DC sehingga mampu mempertahankan kelembaman pada arahnya. Sistem otomatis ini terdiri dari sensor KMZ51 sebagai komponen feedback dan dua motor DC sebagai komponen plant. Pengujian dari sistem otomatis dibagi menjadi tiga yaitu pengujian sensor KMZ51, pengujian PWM sebagai penggerak motor DC dan pengujian performansi kontrol PID. Hasil pengujian menunjukkan nilai ketelitian sensor 99.17%. Pada pengujian PWM diperoleh error pengukuran 1.07% dan pengujian performansi sistem didapatkan bahwa penerapan kontrol PID dapat mengatur putaran motor DC sehingga model sistem mampu mempertahankan arahnya pada set point yang telah ditentukan dengan nilai overshoot maximum kurang dari 10%, rise time 2 detik dan settling time kurang dari 5% yang diperoleh pada Kp= 27, Ki= 6, dan Kd= 40 menggunakan metode trial and error. This research is design of automatic control system which driven by two DC motors that can keep the inertia of direction. The system is composed of sensor KMZ51 as feedback component and two DC motors as plant component. Testing of the automated system divided into three, KMZ51 sensor testing, PWM testing as drive DC motors, and performance testing of PID control system. The results show that the sensor accuracy values 99.17%, on testing the PWM measurement error obtained 1.07%, and testing of performance system obtained that the application of PID control can adjust DC motors rotation so that the model system is able to maintain direction the set point specified with maximum overshoot less than 10%, rise time of 2 seconds and settling time less than 5% were obtained at Kp= 27, Ki= 6, and Kd= 40 using trial and error method
APLIKASI ALAT RADIOGRAFI DIGITAL DALAM PENGEMBANGAN LAYANAN FOTO RONTGEN -, Susilo; -, Sunarno; Setiowati, E; Lestari, L
Jurnal MIPA Vol 35, No 2 (2012): October 2012
Publisher : Jurnal MIPA

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Sistem radiografi digital (RD) selama ini dianggap sebagai teknologi impor yang canggih,  mahal, dan memerlukan kemampuan sumber daya yang tinggi. Pengadaan secara built-in cenderung menyerap APBD cukup besar terutama untuk pelaksanaan otonomi daerah dan desentralisasi, selain itu juga tidak memberi nilai tambah bagi struktur iptek daerah. Dalam upaya pengembangan sistem RD untuk aplikasi medis, penelitian ini mengembangkan sistem pencitraan radiografi digital untuk pengembangan layanan RS Daerah. Melalui penelitian ini, hasil penelitian terdahulu dikembangkan menjadi model prototipe aplikasi pencitraan medis yang dilengkapi dengan sistem pelindung radiasi, dan sistem penangkap gambar yang dibangun dari tabung kedap cahaya, intensifying screen bersama kamera CCD, dan pengolah citra. Hasil penelitian ini adalah berupa model prototype sistem pencitraan radiografi digital (tanpa film) untuk pemeriksaan fraktur tulang dan software analisis citra radiografi digital berbasis Matlab 7.1, sehingga pencitraan medis ini dapat diduplikasi oleh unit kendali mutu yang ada di rumah sakit kota/daerah. Digital radiography system (RD) is considered as advanced and expensive imported technology, and it requires high resource capabilities. Built-in procurement tends to absorb substantial budget, especially for the implementation of regional autonomy and decentralization, but it also does not add value to the structure of the science and technology region. To develop the RD system for medical applications, this study developed a digital radiographic imaging system for the development of regional hospital services. Through this research, the results of previous studies developed a prototype model of medical imaging application that comes with the system of radiation protection and image capture system built from a light-tight tube, intensifying screen with a CCD camera and image processing. This study results a prototype model of digital radiography imaging system (without film) for examination of bone fractures and image of digital radiography software analysis based on Matlab 7.1, so that medical imaging can be duplicated by the quality control unit of city/regional hospital.
RANCANG BANGUN SISTEM PENCITRAAN RADIOGRAFI DIGITAL UNTUK PENGEMBANGAN LABORATORIUM 1) FISIKA MEDIK UNNES Susilo, Susilo; Supriyadi, Supriyadi; Sutikno, Sutikno; Sunarno, Sunarno; Setiawan, Rudi
Sainteknol : Jurnal Sains dan Teknologi Vol 12, No 1 (2014): June 2014
Publisher : Unnes Journal

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/sainteknol.v12i1.5427

Abstract

Telah dilakukan modifikasi sistem penangkap gambar kedap cahaya yang dapat menampilkan langsung citra radiograf digital pada layar monitor PC dan menyimpan file radiograf tersebut sehingga bisa ditampilkan kembali. Penelitian ini bertujuan membangun model prototip sistem penangkap gambar berbasis kamera digital, sehingga hasilnya bisa diproses lebih lanjut menggunakan perangkat lunak pengolah citra berbasis Matlab. Hasil pemotretan dengan sinar-X pada benda uji dan volunteer digunakan untuk menguji keajegan hasil radiograf tersebut, dan diperoleh perbaikan kontras yang signifikan, ditunjukkan dengan tampilan histogram, nilai MSE dan PSNR yang sesuai. Aplikasi perangkat lunak tersebut dalam menganalisis radiograf benda uji, kaki, tangan serta stepwedge menunjukkan juga kenaikan ukuran file, kontras citra radiograf dan resolusi citra. Hasil ini menunjukkan bahwa pada model prototip penangkap gambar yang dilengkapi dengan perangkat lunak berbasis Matlab dapat dikembangkan untuk pemeriksaan radiografi digital yang handal, bisa ditangani sendiri, ramah lingkungan (tanpa zat kimia) serta paper less, sesuai dengan pesan program konservasi Unnes.
FABRIKASI STRUKTUR HETERO CDTE/CDS:ZN DENGAN DC MAGNETRON SPUTTERING (HOMEMADE) UNTUK APLIKASI SEL SURYA Sugianto, Sugianto; Sunarno, Sunarno
Sainteknol : Jurnal Sains dan Teknologi Vol 11, No 2 (2013): December 2013
Publisher : Unnes Journal

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/sainteknol.v11i2.5577

Abstract

Deposisi film tipis struktur hetero CdTe/CdS:Zn dilakukan dengan metode dc magnetron sputtering (home made) untuk aplikasi sel surya. Struktur hetero yang ditumbuhkan adalah tipe “Superstrate configuration” dengan struktur Ag/p-CdTe/n-CdS:Zn/ITO/glass. Optimasi performa struktur-hetero dilakukan dengan doping Zn pada CdS, variasi daya plasma dan treatment CdCl pada film CdTe. Karakterisasi sifat listrik struktur-hetero menggunakan pengukuran arus-tegangan (I-V). Pengukuran I-V pada kondisi tanpa penyinaran (dark) menunjukkan struktur hetero Ag/CdTe/CdS:Zn/ITO/glass mempunyai karakteristik ideal diode persambungan p-n. Arus saturasi difusi dan arus saturasi rekombinasi pada saat diberikan bias maju besarnya orde 10 2 A. Penambahan doping Zn (5%) pada CdTe telah meningkatkan performa struktur hetero Ag/CdTe/CdS:Zn/ITO/glass. Penumbuhan struktur hetero dengan daya tinggi dan treatmen CdCl telah meningkatkan efesiensi sel surya. Tegangan open circuit (V oc 2 ) dan arus short circuit (I ) yang masih rendah mengindikasikan bahwa hambatan seri (Rs) dari material struktur hetero masih besar. sc -8 – 10 -11
SOLID WASTE-SILICA COMPOSITE FOR HIGH STRENGTH AND LIGHTWEIGHT MATERIAL APPLICATION Masturi, M.; Rustad, S.; Sunarno, S.; Hindarto, N.
Jurnal Pendidikan Fisika Indonesia Vol 12, No 1 (2016): January 2016
Publisher : Physics Department, Faculty of Mathematics and Natural Sciences, Semarang State University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/jpfi.v12i1.4289

Abstract

The solid waste composite was successfully made. Preliminary, the composite was synthesized using polyurethane as binder mixed with the solid waste using simple mixing method and then hot-pressed at at pressure of 4 metric-tons and temperature of 100°C for 20 minutes. To enhance its strength, silica nanoparticles with varied content then were added in the polyurethane-solid waste mixture. From the compressive strength test, it was obtained that polyurethane-solid waste composite with solid waste volume fraction of 87.15% had optimum compressive strength of 160 MPa. Meanwhile, for silica addition with the fraction of 0.4975%, the compressive strength became 200 MPa, or increased 23% of that without nanosilica. The enhancement was also briefly confirmed from FTIR Spectroscopy where some polyurethane spectra shifted small due to silica addition, especially in amine and carbonyl groups as its active groups. The strength is better than of brick (80 MPa), shalestone (73 MPa), silstone (92 MPa) and other stones. From density measurement, the composite-produced has density about 0.7 g/cm3 that comparable to Jati (Tectona grandis) and Mahoni (Swietenia macrophylla) having densities about 0.8 g/cm3 and 0.7 g/cm3 respectively. Therefore, this composite is very adequate for building material application to compete the woods.  Komposit sampah sudah berhasil dibuat. Mula-mula, komposit disintesis dengan menggunakan poliuretan sebagai pengikat yang dicampur dengan sampah melalui metode pencamnpuran sederhana (simple mixing), kemudian dihot-press pada tekanan 4 metric ton dan suhu 100°C selama 20 menit. Untuk meningkatkan kekuatan mekaniknya, nanopartikel silica dengan berbagai komposisi ditambahkan dalam campuran poliuretan-sampah. Dengan menggunakan uji kekuatan tekan, didapatkan komposit poliuretan-sampah dengan fraksi volume sampah sebesar 87,15% memiliki kekuatan tekan sebesar 160 MPa. Selanjutnya, dengan penambahan silica sebesar 0,4975% (v/v) kekuatan tekan komposit menjadi 200 MPa, atau meningkat sebesar 23% dibandingkan komposit tanpa silica. Peningkatan ini juga dikonfirmasi melalui FTIR Spectroscopy yang menunjukkan adanya pergeseran kecil pada puncak spektra poliuretan akibat penambahan silica, utamanya pada gugus fungsi amina dan karbonil. Kekuatan mekanik komposit ini lebih baik daripada batu bata (80 MPa), batuan shale (73 MPa), batuan siltstone (92 MPa) dan beberapa jenis batuan yang lain. Dengan menggunakan uji kerapatan didapatkan komposit ini memiliki massa jenis 0,7 g/cm3, setara dengan kayu Jati (Tectona grandis) dan Mahoni (Swietenia macrophylla) yang memiliki massa jenis masing-masing 0,8 g/cm3 dan 0,7 g/cm3. Ini menunjukkan komposit yang dihasilkan sangat cocok untuk diaplikasikan sebagai bahan bangunan pengganti kayu.
PENGENDALIAN KELAJUAN KENDARAAN MENGGUNAKAN FUZZY LOGIC CONTROLLER (FLC) PADA SISTEM CRUISE KONTROL Susanto, S.; Sunarno, S.
Jurnal MIPA Vol 39, No 1 (2016): April 2016
Publisher : Jurnal MIPA

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Pengendalian kelajuan kendaraan menggunakan FLC pada cruise control telah dilakukan dengan menginjeksi sistem fuzzy pada sistem gerak kendaraan. Sistem fuzzy terdiri dari dua himpunan masukan berupa error kelajuan dan laju error kelajuan sistem. Penambahan Fuzzy Logic Controller pada sistem gerak kendaraan berpengaruh terhadap respon sistem untuk mencapai kecepatan yang diinginkan. Dengan penambahan FLC respon kecepatan dalam mencapai kecepatan yang diinginkan semakin cepat sehingga sesuai untuk diterapkan pada cruise control.Control vehicle speed using the cruise control FLC has been done by injecting a fuzzy system on the vehicle motion system. The system consists of two sets fuzzy input is the speed error and the error rate of the speed of the system. The addition of Fuzzy Logic Controller in the vehicle motion system affect the response of the system to achieve the desired speed. With the addition of FLC response speed in reaching the desired speed more quickly so appropriate to be applied to the cruise control.
Rancang Bangun Sistem Penangkap Gambar Radiograf Digital Berbasis Kamera DSLR -, Susilo; -, Supriyadi; -, Sutikno; -, Sunarno; Setiawan, R.
Jurnal Pendidikan Fisika Indonesia Vol 10, No 1 (2014)
Publisher : Department of Physics, Faculty of Mathematics and Natural Sciences

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/jpfi.v10i1.3052

Abstract

Telah dilakukan modifikasi sistem penangkap gambar kedap cahaya yang dapat menampilkan langsung citra radiograf digital pada layar monitor PC dan menyimpan file radiograf tersebut sehingga bisa ditampilkan kembali. Penelitian ini bertujuan membangun model prototip sistem penangkap gambar berbasis kamera digital, sehingga hasilnya bisa diproses lebih lanjut menggunakan perangkat lunak pengolah citra berbasis Matlab. Hasil pemotretan dengan sinar-X pada benda uji dan volunteer digunakan untuk menguji keajegan hasil radiograf tersebut, dan diperoleh perbaikan kontras yang signifikan, ditunjukkan dengan tampilan histogram, nilai MSE dan PSNR yang sesuai. Aplikasi perangkat lunak tersebut dalam menganalisis radiograf benda uji, kaki, tangan serta stepwedge menunjukkan juga kenaikan ukuran file, kontras radiograf dan resolusi citra yang meningkat. Hasil ini menunjukkan bahwa model penangkap gambar yang dilengkapi dengan perangkat lunak berbasis Matlab dapat dikembangkan untuk pemeriksaan radiografi digital yang efektif, efisien dan mempunyai nilai ekonomi yang tinggi. It has been modified a system of light-tight image capturing which can display directly digital radiograph image on the monitor screen of PC and save that radiograph digital image for re-displaying it. This research aims to build a prototype of digital camera based-image capturing, so that the result can be processed further using a mathlab based-image processing software. The imaging process using X-ray on the test materials and volunteers are used to investigate its image consistency and find more contrast image, shown on the histogram, appropriate MSE and PSNR values. The application of this software for analyzing test materials, feet, hands and stepwdge showed the file size increase, radiograph constrast, and image resolution. This result shows that a model of image capturing completed by software based-mathlab can be developed to check an effective, efficient and has an economic value digital radiography test result.