Penyeimbangan Beban Trafo Distribusi Berbasis Data Hasil Pendeteksian Phasa Pelanggan Tegangan Rendah Anang Dasa Novfowan; Dhimas Dhesah Kharisma; Slamet Nurhadi
Elposys: Jurnal Sistem Kelistrikan Vol. 13 No. 2 (2026): ELPOSYS VOL. 13 NO.2 (2026)
Publisher : Politeknik Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33795/elposys.v13i2.9858

Abstract

Load imbalance caused by varied single-phase customer demand can increase neutral current and affect the operational performance of low-voltage distribution systems. This study evaluates a Power Line Carrier (PLC)-based customer-phase identification workflow to support load balancing at the N1223 distribution substation. A field case-study design was used, with phase-current measurements taken at the low-voltage main distribution panel during peak loading and customer phase data verified using a PLC master-slave system. The initial condition (R = 265 A, S = 133 A, and T = 116 A) produced an unbalance index of 36.45% and a neutral current of 141 A. After phase reassignment in Lines B and C, the highest recorded post-balancing unbalance was 5.1%; at 20:00, R = 166 A, S = 185 A, and T = 172 A produced an unbalance index of 4.1%. The post-balancing neutral current was 16.82 A. These findings show that verified customer-phase data provide a traceable basis for selecting rephasing targets. Quantitative neutral-conductor loss estimates are not reported as a main finding because the conductor resistance, length, and cross-sectional area required for independent verification were unavailable.
Karakterisasi Kinerja Pengisian Baterai Sistem PV Off-Grid Berbasis Solar Charge Controller PWM Achmad Walid; Nurhadi Nurhadi; Pondi Udianto
Jupiter: Publikasi Ilmu Keteknikan Industri, Teknik Elektro dan Informatika Vol. 4 No. 5 (2026): September : Jupiter: Publikasi Ilmu Keteknikan Industri, Teknik Elektro dan Inf
Publisher : Asosiasi Riset Ilmu Teknik Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61132/jupiter.v4i5.1657

Abstract

Small Off-Grid photovoltaic systems require a charge controller to transfer energy safely from the photovoltaic module to the battery. This study characterizes the input-output performance of a 30 A pulse-width-modulation solar charge controller connected to a 20 Wp photovoltaic module and a 12 V, 12 Ah battery. Field measurements were conducted in Tunggul Wulung, Lowokwaru, on 5 September 2026 at one-hour intervals from 08:00 to 16:00. Solar irradiance, module surface temperature, photovoltaic voltage-current, and battery-side voltage-current were recorded. Input power, battery charging power, instantaneous measured efficiency, and interval energy efficiency were calculated. Irradiance ranged from 5.0 to 143.8 W/m² and module temperature from 25.4 to 62.5 °C. The maximum panel power was 2.680 W at 08:00, whereas the maximum battery-input power was 2.361 W at 10:00. Trapezoidal integration yielded 12.524 Wh of panel energy and 10.647 Wh of battery-input energy, corresponding to an aggregate energy efficiency of 85.01%. Instantaneous ratios above 100% at 14:00-16:00 occurred at very low power and are interpreted as apparent efficiencies affected by measurement resolution and non-simultaneous readings, not as physical conversion gains. The results provide a preliminary field baseline and emphasize synchronized measurements and uncertainty reporting for subsequent testing.
Annealing effects on single-phase E-I transformer performance under nonlinear loads Slamet Nurhadi; Chandra Wiharya; Satria Luthfi Hermawan; Priya Surya Harijanto; Bakti Indra Kurniawan; Divac Nabiel Akbar
JURNAL ELTEK Vol. 24 No. 2 (2026): October 2026
Publisher : Politeknik Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33795/eltek.v24i2.10746

Abstract

Single-phase E-I transformers are widely used in power-conversion applications, including grid-connected flyback micro-inverters for solar photovoltaic systems, yet their performance often deteriorates due to high core loss and harmonic distortion generated by nonlinear loads. This study evaluated the effect of the annealing process on core loss, voltage regulation, energy efficiency, and voltage/current harmonic distortion of a single-phase E-I transformer under nonlinear loading. Three transformer samples were tested under no-load and nonlinear-load conditions (rectifier and inverter) before and after annealing at 180, 350, and 450 °C for 60 minutes, followed by harmonic-distortion measurement using a power logger on a flexible conveyor system and a single-phase induction motor. Annealing at 350 °C produced the most significant core-loss reduction, from 150.3 W to 110.6 W, while linear-load efficiency reached 97-98% and voltage regulation remained stable near 98%. Harmonic measurements showed voltage total harmonic distortion (THDv) of 5.8% on the flexible conveyor system and 5.6% on the induction motor without a variable speed drive, both below the 8% IEEE 519 limit, while individual current harmonic distortion (IHDi), current total harmonic distortion (THDi), and total demand distortion (TDD) also remained within the standard's safe margins. These findings indicate that medium-temperature annealing can improve the magnetic performance of the transformer core while keeping power quality within standard limits under nonlinear loading. The practical implication is that this annealing guideline can be adopted by small and medium-scale transformer manufacturers to improve energy efficiency without costly equipment investment.
MODIFIKASI DAN PENGATURAN PUTARAN MOTOR PENGGERAK KOMPRESOR PADA ALAT PERAGA SISTEM AC MOBIL Dzaka Yusuf Arifian; Nurhadi Nurhadi
JTAM ROTARY Vol 8, No 2 (2026): JTAM ROTARY
Publisher : Universitas Lambung Mangkurat

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20527/jtam_rotary.v8i2.19610

Abstract

Penelitian ini bertujuan memodifikasi sistem penggerak kompresor pada trainer AC mobil dengan menggunakan motor induksi tiga fasa yang dikendalikan melalui Variable Frequency Drive (VFD). Modifikasi dilakukan terhadap sistem penggerak, komponen refrigerasi yang mengalami kerusakan, serta jalur refrigeran yang mengalami kebocoran. Setelah proses perbaikan, sistem divakum, diisi refrigeran R134a, dan diuji pada tiga tingkat putaran motor, yaitu rendah, sedang, dan tinggi. Hasil pengujian fungsional menunjukkan bahwa VFD mampu mengendalikan putaran motor dan kompresor pada ketiga kondisi operasi. Secara kualitatif, kondisi putaran rendah menghasilkan getaran rendah, kondisi putaran sedang menunjukkan operasi paling stabil, sedangkan kondisi putaran tinggi menghasilkan peningkatan getaran dan kebisingan. Sistem AC dapat kembali beroperasi setelah proses modifikasi. Namun, evaluasi kuantitatif terhadap tekanan, temperatur, getaran, kebisingan, serta kapasitas pendinginan masih diperlukan untuk menentukan pengaruh putaran kompresor terhadap performa sistem secara lebih komprehensif. This study aimed to modify the compressor drive system of an automotive air-conditioning trainer by using a three-phase induction motor controlled through a Variable Frequency Drive (VFD). The modification involved the drive system, damaged refrigeration components, and leaking refrigerant lines. After the repair process, the system was evacuated, charged with R134a refrigerant, and tested at three motor-speed levels: low, medium, and high. Functional testing showed that the VFD was capable of controlling both the motor and compressor speeds under all three operating conditions. Qualitatively, the low-speed condition produced low vibration, the medium-speed condition provided the most stable operation, while the high-speed condition resulted in increased vibration and noise. The air-conditioning system was successfully restored to operation after the modification. However, further quantitative evaluation of pressure, temperature, vibration, noise, and cooling capacity is required to determine the effect of compressor speed on overall system performance more comprehensively.