Simulasi Efek Ukuran dan Lokasi Kebocoran Pipa Pendingin Reaktor Nuklir Menggunakan Fasilitas Eksperimen UUTR.Mod-l Antariksawan, Anhar R.; Juarsa, Mulya; Prasetyo, Joko; Sumarno, Edy; Kiswanta, Kiswanta; Handoyo, Ismu
MESIN Vol 9, No 2 (2007): MEMINIMALKAN KERUGIAN KAMPUS AKIBAT BANJIR
Publisher : Program Studi Teknik Mesin, Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Experimental Simulation of The Effect of Size and Location of Coolant Pipe Break inNuclear Reactor Using UUTR.Mod-l. Several experiments of LOCA with various break size andlocations have been conducted using UUTR.Mod-l testfacility. The break sizes studied are 2 mm, 5 mmand 10 mm, each at hot-leg and cold-leg side. The initial conditions ofthe experiment are 1 MWofpower,primary side pressure of 155 bar approximately, coolant flow rate of 9.8 kg/s and only accumulator isfunctioned as emergency coolant. Both at hot-leg and cold-leg, the break size of 2 mm showed slowerpressure decrease rate and the occurrence of temperature increase early after break. For larger breaksize, pressure decrease is faster and showed rod temperature excursion due to rod uncovering.Concerning the breaklocation, in large break area, cold-leg breakshowed heater temperature excursionearly than in case of hot-leg break. Size and location of break determine the timing of event and, asconsequence, different behavior of response system. In any cases to prevent the fuel temperatureexcursion, the addition ofautomatic depressurizationsystem and installation ofinjection system in upperhead ofpressure vessel have been consideredin the nuclearreactor design.
ANALISIS KURVA PENDIDIHAN DALAM CELAH SEMPIT VERTIKAL UNTUK KASUS BILATERAL HEATING BERDASARKAN PERUBAHAN TEMPERATUR AWAL PLAT Catrawedarma, IGN Bagus; Indarto, Indarto; Juarsa, Mulya; Handoyo, Ismu; Kiswanta, Kiswanta
MEKANIK: Jurnal Ilmiah Teknik Mesin Vol 1 No 2 (2015): November 2015
Publisher : Jurusan Teknik Mesin, Fakultas Teknologi Industri, Institut Teknologi Medan (ITM)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (585.396 KB)

Abstract

Analisis perpindahan kalor pendidihan untuk mengetahui pengaruh temperatur awal plat utama terhadap karakteristik pendidihan yang meliputi waktu rewetting, pola rewetting, fluks kalor, serta Critical Heat Flux (CHF) telah dipelajari berdasarkan kurva pendidihan dan fluks kalor yang dihitung dari transien temperatur permukaan plat, yang merupakan hasil eksperimen dengan menggunakan 2 plat vertikal dengan celah sempit antar plat utama dan penutup adalah 1 mm. Debit dan temperatur air pendingin ditetapkan sebesar 0,09 lt/detik dan temperatur saturasi. Temperatur awal plat utama divariasikan dari 500oC, 550oC, dan 600oC. Hasil analisis menunjukkan bahwa waktu rewetting terendah sebesar 30 sekon dan tertinggi sebesar 290 sekon. CHF tertinggi sebesar 750 kW/m2 dan terendah sebesar 400 kW/m2. Semakin tinggi temperatur awal plat, maka semakin lama waktu rewettingnya. Perubahan temperatur awal plat utama tidak mempengaruhi pola rewetting. Semakin tinggi temperatur awal plat, maka nilai CHF-nya semakin rendah. Daerah didih film tidak sesuai dengan kasus pool boiling. Pada daerah transisi, semakin rendah temperatur awal plat, maka semakin mendekati korelasi Murase (2001). Nilai CHF mendekati korelasi Leinhard. dkk (2002). Titik Leidenfrost sesuai dengan korelasi Zuber (1958). Daerah didih inti mendekati korelasi Murase (2001) untuk superheat vapor.
TEKNIK PERBAIKAN SAMBUNGAN TERMOKOPEL TEMPERATUR TINGGI PADA HEATING-01 Joko Prasetyo Witoko; Kiswanta Kiswanta; Edy Sumarno; Ainur Rosidi; Ismu Handoyo; Khrisna Khrisna
SIGMA EPSILON - Buletin Ilmiah Teknologi Keselamatan Reaktor Nuklir Vol 14, No 2 (2010): Mei 2010
Publisher : Badan Tenaga Nuklir Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2104.405 KB) | DOI: 10.17146/sigma.2010.14.2.2975

Abstract

Telah dilakukan perbaikan sambungan termokopel pada batang pemanas bagian uji HEATING-01. yang batang pemanasnya terbuat dari baja stainless AISI 304 dan memiliki 14 titik termokopel. Pada setiaptitik termokopel sebanyak 8 termokopel dipasang pada 8 posisi 1 titik yang berurutan dan 6 termokopeldipasang pada 3 posisi 2 titik radial. Perbaikan dilakukan karena terjadi penyimpangan yang terlalu besar padahasil fabrikasi sebelumnya. Teknik penyambungan termokopel pada kawat chromel dan kawat alumel dengandiameter 1 mm menggunakan tegangan 13,6 volt dari alat DC power supply. Hasilnya menunjukkan bahwa alatini berfungsi dengan baik setelah dikalibrasi dengan kalibrator JOFRA. Rata-rata penyimpangan yang terjadisebesar -0,1°C.
Analisis Karakteristik Rewetting Dalam Celah Sempit Vertikal Untuk Kasus Bilateral Heating Berdasarkan Perubahan Temperatur Awal Plat IGN. Bagus Catrawedarma; Indarto -; Mulya Juarsa; Ismu Handoyo; Kiswanta -; Ririn Fitriana
Jurnal Energi Dan Manufaktur Vol 5, No.1 April 2011
Publisher : Department of Mechanical Engineering, University of Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (158.238 KB)

Abstract

Boiling heat transfer to analysis of effect main plate initial temperature to rewetting characteristics that arerewetting time, and pattern of rewetting were studied from transient temperature of surface plate. It is as result of experimentusing two vertical plate with 1 mm narrow gap. Debit and temperature of cooling water were controlled about 0,09 lt/s andsaturated temperature. The initial temperatures of main plate were changed from 500°C, 550°C, and 600°C. As results shownthat midle part of main plat has the highest value of rewetting time that is 310 second at 600°C initial main platetemperature, the lowest rewetting time is 40 second at 500oC initial main plate temperature on the bottom part of plate. Thehigher the plate initial temperature, the longer the rewetting time and variation of the plate initial temperatures can notinfluent the pattern of rewetting.