Found 19 Documents
Search

PERENCANAAN SISTEM PENYALURAN AIR LIMBAH DOMESTIK KOTA BOGOR MENGGUNAKAN AIR HUJAN UNTUK DEBIT PENGGELONTORAN (Planning of Domestic Wastewater Sewerage in Bogor City Using Rainwater for Flushing Flowrate) Allen Kurniawan; Nura Adithia Dewi
Jurnal Manusia dan Lingkungan Vol 22, No 1 (2015): Maret
Publisher : Pusat Studi Lingkungan Hidup Universitas Gadjah Mada

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22146/jml.18723

Abstract

ABSTRAKSistem penyaluran air limbah merupakan bagian penting dalam sistem prasarana perkotaan. Tujuan penelitian ini merancang konfigurasi sistem penyaluran air limbah domestik dan memodifikasi sistem drainase skala mikro di Kota Bogor untuk memenuhi debit penggelontoran. Data penelitian berupa data sekunder dari instansi terkait, studi pustaka, dan hasil beberapa penelitian terdahulu. Perkiraan jumlah penduduk setiap kelurahan pada tahun perencanaan 2035 menggunakan metode geometrik. Instalasi Pengolahan Air Limbah (IPAL) dibangun pada dua lokasi yaitu IPAL 1 di Kelurahan Bantarjati dan IPAL 2 di Kelurahan Mekarwangi. Perencanaan blok pelayanan sebanyak 254 buah dan jumlah manhole sebanyak 334 buah. Perhitungan kebutuhan air bersih menghasilkan nilai debit jam puncak air limbah (Qjp) rata-rata sebesar 5,75 L/detik. Debit air bersih menghasilkan perkiraan sebesar 80% air limbah. Nilai Qp pada inlet IPAL 1 sebesar 0,59 m3/detik dengan diameter 900 mm, sedangkan nilai Qp pada inlet IPAL 2 sebesar 1,42 m3/detik dengan diameter 1000 mm. Pengaliran air limbah diusahakan secara gravitasi dengan kedalaman galian maksimum sebesar 6 m. Sistem drainase skala mikro dirancang untuk memenuhi debit penggelontoran. Perhitungan intensitas hujan terpilih menggunakan Metode Sherman. Titik penggelontoran sebanyak 53 titik dengan debit penggelontoran rata-rata sebesar 0,03 m3/detik. Debit saluran drainase rata-rata sebesar 0,25 m3/detik.ABSTRACTSewerage system is an important part of the urban infrastructure. The research objectives were to design a system configuration domestic wastewater sewerage and modify drainage systems in Bogor City for flushing discharge. The research used secondary data from relevant institutions, literature, and the results of previous researches. Estimated of the population of each village in 2035 used geometric method. Wastewater Treatment Plant (WWTP) would be constructed in two locations in Bantarjati and Mekarwangi Village. Planning of services area included 254 blocks and the number of manholes were 334. Clean water which produced peak hours flowrate (Qph) was 5.75 L/sec. Water flowrate produced an estimated of 80% wastewater flowrate. Q peak at the inlet of the WWTP 1 was 0.59 m3/sec with diameter of 900 mm, while Q peak at the inlet of the WWTP 2 was 1.42 m3/sec with diameter of 1000 mm. The stream of wastewater carried out by gravity with the maximum digging depth of 6 m. The system of micro-scale drainage was designed to supply flushing flowrate. Rainfall intensity calculation is done using the Sherman Method with period of 20 years rain repetition. Flushing points were 53 with flowrate average of 0.03 m3/sec. Drainage flowrate average was 0.25 m3/sec. Micro-scale drainage was designed rectangular. Result of the width and height average dimension were 0.43 m and 0.42 m, respectively.
Kinerja Unit dan Isoterm Adsorpsi Filtrasi Multimedia Pada Sistem Resirkulasi Akuakultur Ikan Hias Berdasarkan Variasi Ketebalan Media dan Debit Aliran Tarissa Kristina; Teuku Devan Assiddiqi; Budi Indra Setiawan; Chusnul Arif; Allen Kurniawan
Jurnal Ilmu Lingkungan Vol 21, No 4 (2023): October 2023
Publisher : School of Postgraduate Studies, Diponegoro Univer

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/jil.21.4.933-945

Abstract

Limbah cair akuakultur memiliki kandungan bahan organik dan anorganik, seperti amonia dan nitrit, yang dapat menyebabkan pencemaran di badan air. Teknologi sistem resirkulasi akuakultur (RAS) dapat memberikan alternatif dengan memanfaatkan sumber daya air terbatas untuk mereduksi kontaminan organik air limbah akuakultur. Penelitian ini menggunakan kombinasi unit filter multimedia (FMM), filter karbon aktif (KA), dan nano membran (NF). Tujuan penelitian ini dirancang untuk menguji kinerja FMM, menentukan ketebalan media filter optimal, serta menentukan estimasi model isoterm adsorpsi sebagai penunjang aspek desain FMM. Enam kombinasi variasi ketebalan media zeolit (30, 60, 90 cm) dan debit aliran (22,5; 45 L/menit) digunakan untuk menguji kinerja unit. Penyisihan amonia dan nitrit berturut-turut sebesar 99,85% dan 100% lebih efektif terjadi pada ketebalan zeolit sebesar 90 cm dan debit 45 L/menit. Terkait beban biaya operasional FMM, efisiensi kedua parameter tersebut tidak diperlukan hingga mencapai optimal apabila dintegrasikan dengan unit CA dan NF. Berdasarkan analisis pemodelan isoterm adsorpsi, Model Langmuir (KL = 90,18 L/mg) untuk nitrit, serta Temkin (KT = 15,68 L/mg) dan Hasely (K= 0,45 L/mg) untuk amonia merupakan model terbaik untuk mengestimasi koefisien kapasitas adsorpsi. Nilai tersebut dapat digunakan untuk memprediksi konsentrasi nitrit dan amonia di efluen berdasarkan uji perfoma model dan analisis statistik. Aquaculture wastewater contains ammonia, nitrite, and other materials which can contribute to water pollution. Recirculation aquaculture system (RAS) technology offers an alternative approach by utilizing limited water resources to reduce organic contaminants. This research aimed to evaluate the performance of a multimedia filter (FMM), activated carbon filter (KA), and nano-membrane (NF) combination. The study focused on assessing FMM efficiency, determining the optimal filter media thickness, and selecting the appropriate adsorption isotherm model for FMM design. Six combinations of zeolite media thickness (30, 60, 90 cm) and flowrates (22.5; 45 L/min) were tested. The results showed that the highest removal efficiencies for ammonia (99.85%) and nitrite (100%) were achieved with a zeolite thickness of 90 cm and a flow rate of 45 L/min. Integrating FMM with CA and NF units can reduce operational costs without compromising efficiency. The Langmuir model (KL = 90.18 L/mg) for nitrite, and the Temkin (KT = 15.68 L/mg) and Hasely (K = 0.45 L/mg) models for ammonia were identified as the best fit models for estimating adsorption capacity coefficients. These coefficients can be used to predict nitrite and ammonia concentrations in the effluent based on performance testing and statistical analysis. 
Incorporating Inhibition Effects and Hydrolysis Biokinetics into the Mathematical Model of Anaerobic Fermentation Allen Kurniawan; Yanuar Chandra Wirasembada; Mark L. Sibag; Erizal Erizal; Chusnul Arif
Jurnal Presipitasi : Media Komunikasi dan Pengembangan Teknik Lingkungan Vol 21, No 1 (2024): March 2024
Publisher : Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/presipitasi.v21i1.26-40

Abstract

Anaerobic digestion is a well-known biological treatment process. It uses less energy, consumes fewer nutrients, converts organic pollutants into methane gas, and produces a small quantity of biomass. The interactions among the various microbes in this complex biological system need to be better understood, and as a consequence, mathematical models need to be revised. This review discusses the principles of biokinetic models published in the literature on anaerobic fermentation as part of the anaerobic digestion process for waste-activated sludge. Biokinetic models for anaerobic fermentation have been developed to predict cell growth, substrate consumption, and gas production. This exploration delves into the incorporation of the hydrolysis stage, a multi-step process entailing the breakdown of carbohydrates, proteins, and lipids within existing biokinetic models. Because there is no single analytical method for accurately determining the biokinetics of anaerobic fermentation of waste-activated sludge incorporating hydrolysis parameters and inhibition effects are proposed to improve the estimated trends of process variables as a function of the design variables.
Model Biokinetika Sistem Kontak Stabilisasi Lumpur Air Lindi Berdasarkan Pengaruh Fosfor dan Variasi Waktu Detensi Unit Kontak Muhammad Faiz Kahendran; Owen Jacob Notonugroho; Chusnul Arif; Ariani Dwi Astuti; Allen Kurniawan
Jurnal Ilmu Lingkungan Vol 22, No 1 (2024): January 2024
Publisher : School of Postgraduate Studies, Diponegoro Univer

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/jil.22.1.28-42

Abstract

ABSTRAK Tempat pemrosesan akhir sampah menghasilkan air lindi dalam kuantitas besar sehingga membutuhkan alternatif unit pengolahan biologis, seperti kontak stabilisasi untuk mereduksi kontaminan. Penelitian ini bertujuan untuk mengevaluasi kinerja unit kontak berdasarkan variasi waktu detensi (HRT) pada kondisi aliran tidak tunak serta menentukan estimasi parameter biokinetika di dalam persamaan model pertumbuhan mikroorganisme. Penelitian diawali dengan mengkonfigurasi unit kontak stabilisasi, menganalisis parameter kualitas air limbah, dan memprediksi parameter biokinetika untuk memperkirakan kualitas air limbah. Validasi nilai biokinetika dilakukan dengan menggunakan metode matematis dan jaringan saraf tiruan (JST). Fungsi penggunaan JST dalam estimasi chemical oxygen demand (COD) efluen tangki kontak dapat dilakukan dengan cepat, memperkecil kesalahan perhitungan estimasi dengan metode matematis, serta bebas digunakan pada kondisi apapun. Berdasarkan hasil penelitian, persentase efisiensi COD pada masing-masing HRT unit kontak 2, 3, dan 4 jam berturut-turut sebesar 26,9%; 35,1%; dan 46,5%. Pengaruh biokinetika terhadap unit pengolahan unit kontak tidak hanya untuk memprediksi pengolahan air limbah, tetapi juga untuk merancang, mengoperasikan, dan mengontrol sistem pengolahan. Berdasarkan metode statistika, model estimasi konsentrasi COD efluen tangki kontak terbaik adalah model dari model JST. Akan tetapi, model ini hanya mengestimasi konsentrasi efluen tanpa memperhitungkan nilai biokinetika. Model Jerusalimski menjadi pilihan terbaik dibandingkan Model Ming untuk mengestimasi nilai biokinetika Ke, Y, μmax, dan Ks berturut-turut sebesar 0,025 hari-1; 28,25 mgMLVSS/mg COD; 3,4 hari-1; dan 21,46 mg/L berdasarkan pengaruh fossfor dan waktu detensi pada kondisi tidak tunak. Peningkatan konsentrasi fosfor di dalam proses pengolahan akan memengaruhi dekomposisi mikroorganisme di dalam biomassa untuk mengambil oksigen terlarut dalam jumlah besar sehingga pertumbuhan mikroorganisme terhambat.Kata kunci: biokinetika, fosfor, jaringan saraf tiruan, kontak stabilisasi, lindi, waktu detensi.ABSTRACT Landfills produce large quantities of leachate that pollutes the water system water pollution, requiring a contact stabilization treatment unit to reduce the high contaminant in the leachate. This study aims to evaluate the performance of the contact unit based on the variation of hydraulic retention time (HRT) under an unsteady state and to estimate the biokinetic parameters by using the microorganism growth model equation. The research was started by configurating the contact stabilization tank, analyzing the wastewater quality parameters, and predicting biokinetics parameters to estimate water quality effluent and design engineering. Biokinetic values were validated using mathematical methods and artificial neural networks (ANN). The function of using ANN in estimating of contact tank effluent chemical oxygen demand (COD) can be done quickly, minimizes estimation errors using mathematical methods and can be used in any condition. Based on research results, the percent removal of COD efficiency in each HRT contact tank of 2, 3, and 4 hours, were 26.9%; 35.1%; and 46.5%, respectively. The effect of biokinetics on contact tank treatment units is not only to predict wastewater treatment, but also to design, operate and control treatment systems. Based on the statistical analysis, the ANN model was the best model for estimating the contact tank effluent concentration. However, the ANN model provided the estimated effluent concentration without considering biokinetic values in detail. The Jerusalimski model is the best fit model compared to the Ming model to estimate the biokinetic values of Ke, Y, μmax, and Ks of 0.025 day-1, 28.25 mgMLVSS/mg COD, 3.4 day-1, and 21.46 mg/L; respectively, based on the effect of phosphorus and detention time in unsteady state. Increasing the phosphorus concentration in the treatment processing will affect the decomposition of microorganisms in the biomass to take up large amounts of dissolved oxygen until the growth of microorganisms is inhibited.Keywords: artificial neural network, biokinetic, contact stabilization, hydraulic retention time, leachate, phosporus
Estimasi Kualitas Efluen Air Lindi Unit Stabilisasi Berdasarkan Parameter Biokinetika pada Sistem Konfigurasi Kontak Stabilisasi Oktavian Wahyu Pratama Ajie; Owen Jacob Notonugroho; Fatihaturrizky Amelia; Ariani Dwi Astuti; Allen Kurniawan
Jurnal Ilmu Lingkungan Vol 22, No 2 (2024): March 2024
Publisher : School of Postgraduate Studies, Diponegoro Univer

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/jil.22.2.528-542

Abstract

Pengolahan air lindi dibutuhkan untuk mereduksi kontaminan material organik, anorganik, dan mikroorganisme patogen. Pengolahan air lindi secara biologis melalui unit kontak stabilisasi adalah unit yang sangat efektif dipilih terkait kinerja dan faktor nilai ekonomi untuk menyisihkan kandungan polutan organik air lindi. Akan tetapi, kinerja dan pemodelan proses stabilisasi pada unit ini belum dianalisis secara detail untuk implementasi skala lapangan. Penelitian ini bertujuan untuk mengevaluasi kinerja proses stabilisasi berdasarkan variasi waktu detensi (HRT), mengestimasi nilai parameter biokinetika terbaik, dan memprediksi konsentrasi substrat efluen hasil pemodelan. Penelitian ini dilakukan pada skala laboratorium menggunakan tiga variasi HRT, sebesar 4, 5, dan 6 jam dan disimulasikan di dalam model pertumbuhan mikroorganisme Monod, Contois, Blackman, dan Chen-Hashimoto pada kondisi aliran tidak tunak. Penyisihan kontaminan terbaik pada unit stabilisasi berdasarkan hasil analisis kinerja sebesar 82% nitrit, 42% amonia, dan 38% chemical oxygen demand (COD) diperoleh dari HRT 6 jam. Parameter biokinetika terbaik berdasarkan analisis numerik dan uji validasi untuk nilai Ke, Y, μmax, dan Ks dihasilkan berturutturut sebesar 2,05 hari-1; 32,88 mgMLVSS/mgCOD; 0,57 hari-1; dan 24,38 mg/L dari model Monod. Konsentrasi efluen COD rata-rata dari model Monod diestimasi sebesar 206,28 ± 27,39 mg/L untuk HRT 4 jam; 159,25 ± 72,06 mg/L untuk HRT 5 jam; serta 126,32 ± 38,44 mg/L untuk HRT 6 jam. Nilai parameter biokinetika tersebut dapat diimplementasikan untuk perencanaan unit stabilisasi pada konfigurasi kontak stabilisasi air lindi skala lapangan.
Optimalisasi Rancangan Unit Kontak Stabilisasi dan Parit Oksidasi untuk Pengolahan Air Limbah Industri Batik berdasarkan Variabel Desain Operasional Allen Kurniawan; Oktavian Wahyu Pratama Ajie; Azizzah Shofiatunnisa’; Teuku Devan Assiddiqi; Alimah Hasyyati Sahda
Jurnal Ilmu Lingkungan Vol 22, No 5 (2024): September 2024
Publisher : School of Postgraduate Studies, Diponegoro Univer

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/jil.22.5.1338-1348

Abstract

Industri batik menghasilkan limbah cair dengan volume besar sebesar 80% dari total kebutuhan air. Integrasi pengolahan biologi dan fisikokimia merupakan alternatif terbaik untuk mereduksi kontaminan organik dan bahan kimia dari proses pewarnaan batik. Optimalisasi pengolahan biologi dari tipe konvensional lumpur aktif dapat menerapkan opsi unit kontak stabilisasi dan parit oksidasi. Penelitian ini bertujuan untuk membandingkan nilai efisiensi polutan organik, ketersediaan lahan, dan pengaruh waktu detensi/hydraulic retention time (HRT) untuk perencanaan unit kontak stabilisasi dan parit oksidasi. Tahapan desain dimulai dengan estimasi debit, konsentrasi polutan, dan penentuan nilai kriteria disain. Karakteristik air limbah industri batik memiliki konsentrasi BOD, COD, dan TSS berturut-turut dalam rentang 2050-2710 mg/L, 3855-78178 mg/L, dan 1180-1315 mg/L. Nilai efisiensi penyisihan bahan organik pada unit kontak sebesar 58,8%; unit stabilisasi sebesar 28,8%, serta unit parit oksidasi 96%. Kapasitas atau volume unit kontak stabilisasi sebesar 520 m3, lebih besar dibandingkan unit parit oksidasi sebesar 115,37 m3. Kontak stabilisasi membutuhkan luas area pengolahan sebesar 130 m2,sedangkan parit oksidasi 96,15 m2. HRT unit kontak stabilisasi (unit kontak sebesar 0,97 jam dan unit stabilisasi sebesar 4,67 jam) jauh lebih singkat dibandingkan parit oksidasi sebesar 27,6 jam. Dengan demikian, HRT singkat dan pada unit kontak stabilisasi dapat mengolah air limbah industri batik dalam kuantitas yang lebih besar dibandingkan unit parit oksidasi. Tergantung dari pencapaian kinerja pengolahan, kontak stabilisasi dan parit oksidasi memberikan solusi alternatif selain unit konvensional lumpur aktif untuk meningkatkan kualitas efluen air olahan. Desain unit ini dapat diimplementasikan untuk skala lapangan sebagai bagian dari integrasi pengolahan biologi dan fisikokimia.
MODEL ESTIMASI BIOKINETIKA UNTUK PROSES POST-DENITRIFIKASI AIR LIMBAH DOMESTIK PADA UNIT ANAEROBIC BAFFLED REACTOR Allen Kurniawan; Fatihaturrizky Amelia; Adhirajasa Wirayudhatama; Sulpa Yudha Prawira
JURNAL SUMBER DAYA AIR Vol 17, No 2 (2021)
Publisher : Direktorat Bina Teknik Sumber Daya Air, Kementerian Pekerjaan Umum dan Perumahan Rakyat

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32679/jsda.v17i2.701

Abstract

This study developed a combination of Continuous Stirred Tank Reactor (CSTR) for the acid fermentation and the Anaerobic Baffled Reactor (ABR) post-denitrification through high nitrite injection. Volatile Fatty Acids (VFAs) as a substrate for the post-denitrification process were optimally produced in the acid fermentation process. The aim of this study was to obtain the estimation of biokinetic values to predict the effluent wastewater quality in ABR post-denitrification process under unsteady state. The reactor was operated for HRT 7 days at temperature 25-28 ˚C and pH 6-7,2. The influent and effluent substrate concentration were monitored continuously for 160 days. Post-denitrification biokinetic from the Contois equation resulted in the value of hydrolysis rate (Kh) of 0.077 day-1, the substrate transport rate (k) of 4.364×10-6 Lmg-1day-1, maximum specific growth rate (μmax) of 0.559 day-1, half saturation constant (KS) of 0.209 mgL-1, microbial decay coefficient (b) of 0.0145 days-1; yield coefficient (Y) of 0.084 g-VSSg-COD-1. The validation of biokinetic parameters based on statistical analysis showed fairly precise results following the trend of experimental data to determine the substrate concentration in the effluent unit. Therefore, the biokinetic values can be applied in the design of ABR post-denitrification using primary sludge incorporation with high strength nitrate.Keywords:  Anaerobic baffled reactor, biokinetics, Contois, hydrolysis, post-denitrification.
Inisiasi Pengolahan Air Embung dengan Teknologi Multimedia Filter (MMF) sebagai Solusi Air Bersih di Kabupaten Bojonegoro Chusnul Arif; Allen Kurniawan; Endang Warsiki; Teuku Devan Assiddiqi; Ahmad Rijani Hasby
Agrokreatif: Jurnal Ilmiah Pengabdian kepada Masyarakat Vol. 10 No. 3 (2024): Agrokreatif Jurnal Ilmiah Pengabdian Kepada Masyarakat
Publisher : Institut Pertanian Bogor

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29244/agrokreatif.10.3.324-332

Abstract

Clean water and proper sanitation are fundamental human needs. Nganti Village, located in Ngraho Subdistrict, Bojonegoro Regency, faces significant drought and clean water shortages, particularly during the dry season. The water quality remains subpar despite the presence of springs and water reservoirs. Consequently, processing raw water from the village's reservoir can offer a viable solution. This service activity aims to harness water reservoirs as a clean water source through multimedia filter (MMF) technology. The activities, conducted from 2022 to the end of 2023, encompass four stages: socializing the program plans, constructing multimedia filters (MMF), installing the water treatment unit on-site, and evaluating water quality, followed by necessary follow-ups. The primary activities involve installing water treatment units with MMF technology in collaboration with village officials and the community. The treated water is then tested for quality at the IPB University laboratory. Test results indicate that MMF technology significantly improves water quality, reducing parameters such as Magnesium, Manganese, Calcium, Iron, and Phosphate by 25.8‒97.8%, thus meeting quality standards. However, some parameters, such as TSS, COD, and Zinc, still exceed quality standards, necessitating further processing. This advanced water treatment requires involvement from the local government, particularly in funding through community empowerment programs, to install advanced treatment units and provide operational support for these units.
Pengaruh Kecepatan Rotasi Unit Modifikasi Rotating Biological Contactor terhadap Kinerja Pengolahan Limbah Cair Kelapa Sawit Rahmadi, Rais; Nugrohoputri, Allifiya Salsabil; Adam, Mayandra Salsabhila; Astuti, Ariani Dwi; Kurniawan, Allen
Jurnal Ilmu Lingkungan Vol 23, No 1 (2025): January 2025
Publisher : School of Postgraduate Studies, Diponegoro Univer

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/jil.23.1.73-84

Abstract

Limbah cair kelapa sawit (LCKS) mengandung bahan organik dan padatan tersuspensi yang tinggi sehingga berbahaya jika dibuang ke lingkungan tanpa melalui proses pengolahan. Beberapa modifikasi unit pengolahan biologis terus dikembangkan untuk mengolah LCKS, antara lain unit rotating biological contactor (RBC). Penelitian bertujuan untuk mengidentifikasi pengaruh variasi kecepatan rotasi dan penggunaan bioball terhadap kinerja unit modifikasi RBC. Penelitian ini dilakukan dengan menggunakan unit RBC berskala laboratorium dengan variasi kecepatan rotasi sebesar 3, 5, dan 8 rpm. Hasil penelitian menunjukkan bahwa kecepatan rotasi secara signifikan memengaruhi kinerja sistem RBC. Penurunan kecepatan rotasi dari 8 rpm menjadi 3 rpm meningkatkan efisiensi penyisihan soluble chemical oxygen demand (SCOD) secara signifikan dari 62% menjadi 67,4% dan efisiensi total suspended solid (TSS) dari 66% menjadi 92,4%. Kecepatan rotasi rendah pada kandungan organik dan padatan tersuspensi yang tinggi akan memungkinkan lebih banyak waktu kontak antara LCKS dan mikroorganisme sehingga proses transfer oksigen menjadi lebih optimal untuk proses biodegradasi substrat. Walaupun efisiensi SCOD dan TSS mengalami peningkatan yang signifikan, nilai konsentrasi kedua parameter belum memenuhi baku mutu. Oleh karena itu, unit modifikasi RBC perlu diintegrasikan dengan unit pra-pengolahan seperti koagulasi-flokulasi atau media pertumbuhan attached growth tipe lain, seperti honeycomb untuk menghasilkan nilai konsentrasi efluen yang lebih optimum.