Hanny Vistanti
Balai Besar Teknologi Pencegahan Pencemaran Industri

Published : 3 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 3 Documents
Search

Implementation Of Electrocatalytic Reactor As Oxidation Unit For Residual Reagent Wastewater Of Testing Laboratory Aris Mukimin; Kukuh Aryo Wicaksono; Nur Zen; Agus Purwanto; Hanny Vistanti
Jurnal Riset Teknologi Pencegahan Pencemaran Industri Vol. 9 No. 2 (2018)
Publisher : Balai Besar Standardisasi dan Pelayanan Jasa Pencegahan Pencemaran Industri

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21771/jrtppi.2018.v9.no2.p11-20

Abstract

The remaining reagent from the sample analysis process become a significant source of hazardous waste of laboratory tasting activities. Methylene blue, phenol and oil are pollutants common in the remaining reagent waste. The electrocatalytic reactor is effective oxidation units for these organic pollutants. The reactor was made for a 50 L capacity with cylindrical metal oxide as the anode. The three anode which 6 cm in diameter and 50 cm in length were paired stainless cathode with the distance of 2.5 cm. The reactor was also equipped with a stirrer that is connected to the motor so that the mass transfer and oxidizing agents is more effective. The reactor application was carried out by feeding the remaining reagent waste into the electrocatalytic unit and giving DC potential 5 Volt. Each COD content for reagent waste of detergent: 2864 mg/L, phenol: 838 mg/L and oil: 708 mg/L. The reactor has reduced COD to 2157 mg/L (detergent), 399 mg/L (phenol) and 506 mg/L (oil) for 120 minutes. The high COD content in residual is caused by solvent (chloroform or hexane) that used at extraction step in determining the process of a sample. This compound is tough to oxidize into CO2 by OH radical or hypochlorite acid formed at the anode during the electrolysis process
Enhanced Performance Of Multi-Stage Anaerobic Digestion Of Tofu Wastewater: Role Of Recirculation Hanny Vistanti; Rizal Awaludin Malik
Jurnal Riset Teknologi Pencegahan Pencemaran Industri Vol. 10 No. 1 (2019)
Publisher : Balai Besar Standardisasi dan Pelayanan Jasa Pencegahan Pencemaran Industri

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21771/jrtppi.2019.v10.no1.p29-37

Abstract

Continuous three-stage anaerobic reactors with recirculation system were employed to treat real tofu wastewater. The system consists of 3 reactors connected in series and effluent of the last reactor was partly returned as feed of the first reactor along with fresh wastewater. The recirculation system was conducted on four variations of recirculation ratio (RR)s of 0, 1.0, 1.3, and 1.5 to evaluate the influence of recirculation on stability and performance of anaerobic system. Results showed that recirculation improved the performance of anaerobic digestion. COD was fluctuated without recirculation and gradually decreased to 373 and 298 mg/L at RR 1.3 and 1.5, respectively. Likewise, pH value was dropped to 6.5 at RR 0, and started to increase to approximately 8.0 upon employing recirculation. In addition, the system also showed excellent toleration against rise in ammonia loading, with effluent ammonia approximately 4.678 mg/L. The findings showed that the system employed had excellent efficiency and stability in treating tofu wastewater.
Performance of a Full-Scale Anaerobic Digestion on Bakery Wastewater Treatment : Effect of Modified Distribution System Hanny Vistanti; Rizal Awaludin Malik; Aris Mukimin
Jurnal Riset Teknologi Pencegahan Pencemaran Industri Vol. 11 No. 1 (2020)
Publisher : Balai Besar Standardisasi dan Pelayanan Jasa Pencegahan Pencemaran Industri

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21771/jrtppi.2020.v11.no1.p12-18

Abstract

The effectiveness of a full-scale anaerobic digestion pretreatment was evaluated and the effect of wastewater distribution system was determined on the performance of bakery wastewater (BW) treatment. The BW was fed to 3 series of anaerobic compartments as the main degradation process. The distribution system of first compartment was modified and circulated to enhance contact and efficiency. While the effluent of last compartment was partly returned to the first compartment as an external circulation and the other part was further processed in activated sludge under aerobic conditions. The overall system was able to remove chemical oxygen demand (COD), total suspended solids (TSS), and biochemical oxygen demand (BOD) up to 97.7%, 99.7%, and 99.6%, respectively, at maximum organic loading rate of 6.3 kg COD/m3day. High removal of pollutants indicated that modified distribution of circulation is advantageous to the BW treatment