Claim Missing Document
Check
Articles

Found 26 Documents
Search

Analisis Panel Surya Dengan Variasi Jenis Material Sel Surya Ambar Yulianti; Fakhruddin Mangkusasmito
Gema Teknologi Vol 22, No 4 (2024): October 2023 - April 2024
Publisher : Vocational School Diponegoro University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/gt.v22i4.90301

Abstract

This study aims to analyze the performance of various types of solar panels based on solar cell materials and technologies in order to determine energy conversion efficiency and their suitability for specific applications. The three main materials examined are monocrystalline silicon, polycrystalline silicon, and thin-film, each with different characteristics in terms of light absorption, efficiency, and environmental durability. Emerging technologies such as Passivated Emitter and Rear Cell (PERC) and tandem cells are also analyzed to assess their potential performance improvements over conventional technologies. The research was conducted through experimental testing and simulations, measuring the power output and efficiency of each panel type under different environmental conditions, such as varying light intensities and operational temperatures. The results show that monocrystalline silicon panels with PERC technology deliver the highest energy conversion efficiency, while thin- film panels perform better in low-light conditions and offer greater flexibility. These findings provide a comprehensive understanding of the advantages and limitations of each solar panel material and technology, serving as a valuable reference for selecting the most suitable panel type for household, industrial, or large-scale renewable energy projects.
Rancang Bangun Sistem Dosing Nutrisi Otomatis Berbasis ESP32 Menggunakan Kendali PID Adaptif dan Pemantauan IoT Fahren Diaz; Fakhruddin Mangkusasmito
Gema Teknologi Vol 23, No 1 (2024): April 2024 - October 2024
Publisher : Vocational School Diponegoro University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/gt.v23i1.90336

Abstract

Nutrient management in modern hydroponic systems requires a high degree of precision to optimize plant growth. Controlling nutrient concentration levels in parts per million (PPM)—whether manually or using conventional on/off systems—is often inefficient and prone to causing overshoot. This study aims to design and build a prototype of an automated nutrient dosing system using an ESP32 microcontroller equipped with an adaptive Proportional-Integral-Derivative (PID) control algorithm and integrated with Internet of Things (IoT) technology. The system uses a Total Dissolved Solids (TDS) sensor to measure solution concentration, a DS18B20 temperature sensor for water temperature compensation, and three DC peristaltic pump actuators controlled via an L298N driver module using PWM signals. A heuristic gain scheduling (auto-tuning) algorithm was implemented so that the PID parameters could dynamically adjust their values based on the magnitude of the actual error. Test results showed that the adaptive PID method was able to respond quickly and settle stably without excessive overshoot. In a rise test with a setpoint of 400 PPM, the system achieved a rise time of 215.6 seconds with minimal overshoot of 0.20% and a steady-state error of 5.07 PPM. This system also proved resilient in handling sudden external disturbances in the form of added distilled water, with a recovery time of 96.5 seconds and a maximum overshoot of 5.00%. The integration of IoT infrastructure via the Blynk platform, automatic logging to Google Spreadsheets, and the presence of a Local Web Server successfully enabled users to monitor operations in real-time from a distance. It can be concluded that the design of this device effectively addresses the weaknesses of static control systems and provides high operational efficiency in hydroponic cultivation.
Prototype Pendeteksi Gangguan Dan Monitoring Arus Pada NH-FUSE Di PHB-TR Dilengkapi Data Logger Berbasis IoT (Internet Of Things) Prawira Duta Kusuma; Fakhruddin Mangkusasmito
Gema Teknologi Vol 22, No 1 (2022): April 2022 - Oktober 2022
Publisher : Vocational School Diponegoro University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/gt.v22i1.90242

Abstract

A Low-Voltage Distribution Panel (PHB-TR) is a component within a Low-Voltage Distribution Network (JTR) that serves to connect, distribute, protect, and control electrical power downstream of a distribution transformer. The protection system within a PHB-TR utilizes NH-fuses as the primary protective device, acting as current limiters and safeguards against overcurrent conditions. According to reports from UP3 Purwokerto, faults within PHB-TR units remain a frequent occurrence. Furthermore, there have been numerous customer reports regarding prolonged response times for faults in the Low-Voltage Distribution Network, as technicians are often required to visit each site individually to perform maintenance. Consequently, there is a need for an innovation that enables PLN personnel to identify faults and monitor the status of PHB-TR units more effectively and efficiently. Data indicates that many PHB-TR faults are caused by damaged or blown NH-fuses that have not yet been replaced. This article addresses these issues by proposing a device for fault detection and current monitoring in PHB-TR NH-fuses, equipped with an IoT-based (Internet of Things) data logger. The device can transmit information to PLN personnel within 15–30 seconds of a fault occurring. It detects several types of issues: blown NH-fuses (when current exceeds the nominal rating), insulation breakdown (detected via input voltage at the fuse holder), and load imbalance during overcurrent conditions (exceeding a 20% variance between phases). When a fault is detected, an LED indicator illuminates, and personnel receive a notification via an application, accompanied by an audible alarm. The core components of this device include the PZEM-004T 10A (version 3) current and voltage sensor; an Arduino Mega 2560 microcontroller for data processing; a 20x4 LCD for real-time display of current and voltage values; and a MicroSD card module combined with an RTC (Real-Time Clock) for data logging. Additionally, an ESP8266 (NodeMCU) Wi-Fi module is integrated to transmit information regarding faults at the low-voltage distribution panel (PHB-TR) to the Blynk application. This device enables faster fault resolution at the PHB-TR, reduces operational maintenance costs, simplifies monitoring for PLN personnel, and improves the company’s performance metrics—specifically the Key Performance Indicators (KPIs) related to SAIDI and SAIFI. Furthermore, customers benefit from enhanced service, as power outages become less frequent and shorter in duration, ultimately strengthening PLN’s public image
Rancang Bangun Mesin Coil Winding Otomatis Berbasis Mikrokontroler Arduino Nano dan Motor Stepper Nema17 Untuk Coil Skala Kecil Uwaeis Bima Pangestu; Fakhruddin Mangkusasmito
Gema Teknologi Vol 22, No 4 (2024): October 2023 - April 2024
Publisher : Vocational School Diponegoro University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/gt.v22i4.90303

Abstract

The coil-winding process is still largely performed manually, particularly in small-scale industries, assembly workshops, and educational laboratories, resulting in several drawbacks such as reliance on operator skill, relatively long production times, and inconsistent winding quality. This study aims to design and build an automatic coil-winding machine based on an Arduino Nano with a NEMA 17 stepper motor drive. The developed system uses two stepper motors—one to rotate the spool and the other to guide the wire—with the number of windings and wire diameter controlled via input buttons connected to an LCD as the user interface, as well as a limit switch to restrict the movement of the wire-guiding mechanism. Testing was conducted using 0.15 mm diameter enameled wire of Brand A, 0.15 mm of Brand B, and 0.30 mm wire. System performance was evaluated by measuring coil resistance, analyzing the winding distribution at four measurement points (P1, P2, P3, and P4), and performing statistical analysis using mean, standard deviation, and coefficient of variation. The test results showed that all measurement points had relatively small standard deviations, indicating that the resulting winding distribution was uniform, while the accuracy calculations showed values above 98% for all wire variations tested. Based on these results, the developed automatic coil winder is capable of performing the winding process automatically
Simulasi Manuver Pada Jaringan Tegangan Menengah Penyulang Tanjung Jati B 03 PT PLN (Persero) Berbasis Arduino Mega 2560 Dengan Monitoring VT SCADA 12.1 Aulia Nurul Yunizah; Fakhruddin Mangkusasmito
Gema Teknologi Vol 21, No 3 (2021): April 2021 - October 2021
Publisher : Vocational School Diponegoro University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/gt.v21i3.90271

Abstract

A protection system is necessary in a distribution network to ensure the network remains reliable. The purpose of protection equipment in a distribution network is to minimize damage to the system. In addition, protective equipment is also useful for minimizing the spread of faults so that outages can be limited to smaller areas. Given these functions, network maneuvers are necessary, utilizing protective equipment to prevent faults from spreading further. To facilitate learning about network maneuvers, a maneuver simulation tool was developed for this final project. The results of experiments conducted on this simulation tool showed that the PMT was set to a current of 0.5 A, the recloser was set to a current of 0.5 A, and the LBS was set to a current of 0.4 A.
Rancang Bangun Thermal Energy Storage Sebagai Penyimpanan Energi Berbasis Solar Panel Gilar Wirayudha; Fakhruddin Mangkusasmito
Gema Teknologi Vol 23, No 2 (2025): October 2024 - April 2025
Publisher : Vocational School Diponegoro University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/gt.v23i2.90343

Abstract

The intermittent nature of solar energy causes photovoltaic power output to fluctuate with solar irradiance, requiring an energy storage system to maintain energy availability when panel output decreases. This study designs, constructs, and evaluates a silica-sand-based Thermal Energy Storage prototype powered directly by photovoltaic panels. The prototype uses 57 kg of silica sand with a particle size of 30–50 mesh as a sensible heat storage medium. The final configuration employs two 545 Wp photovoltaic panels connected in series, two series-connected resistive heaters rated at 42 V and 500 W each, two K-type thermocouples, and rockwool-aluminum foil insulation. An ESP32 and Arduino Nano monitoring system records sand temperature, voltage, current, power, and estimated solar irradiance to a spreadsheet. Three configurations were evaluated. The highest temperature increased from 103.63°C in the first configuration to 195.13°C in the second and 230.13°C in the third. Complete insulation enabled the system to retain an average temperature of 100.09°C after approximately 16 h of cooling, with an average cooling rate of 5.84°C/h. For the analyzed charging period, 4,099 Wh of electrical energy produced 1,703.49 Wh of stored thermal energy, corresponding to a thermal storage efficiency of 41.56%. The results show that increasing the number of panels and heaters, combined with comprehensive insulation, improves heating and heat-retention performance.