Testing of Model Water Chiller System with Hidrokarbon as a Primer Refrigeran Nengah Suarnadwipa; Ketut Astawa
Jurnal Energi Dan Manufaktur Vol 3, No.1 April 2009
Publisher : Department of Mechanical Engineering, University of Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (108.227 KB)

Abstract

Now days, there are two issues that give a negative impact on the environment due to the uses of synthetic refrigerant on therefrigeration system and air conditioning system. The first issue was the Ozon Layer Depletion and the second issue was theGlobal Warming. Regarding those condition, it will be investigated the design and examination of performance the use of thesplit type AC system as water chiller system and using hydrocarbon as a primer refrigerant. As a result, in the examination ofthe standard split type AC system using refrigerant R-22, it founded that the cooling rate of 1958 Watt and COP of 5.29.While the examination on the modified split type AC system into water chiller system using hydrocarbon (hycool 22), hasgiven cooling rate of 1832 Watt and COP of 4.19. Finally, it could be councluded that the split type AC system could be usedas water chiller system.
Analisa Performansi Sistem Pendingin Ruangan dan Efisiensi Energi Listrik padaSistem Water Chiller dengan Penerapan Metode Cooled Energy Storage Komang Metty Trisna Negara; Hendra Wijaksana; Nengah Suarnadwipa; Made Sucipta
Jurnal Energi Dan Manufaktur Vol 4, No.1 April 2010
Publisher : Department of Mechanical Engineering, University of Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (765.733 KB)

Abstract

Untuk menghemat penggunaan energi listrik sebagai akibat penggunaan AC (air conditioning) yang semakin meningkatmaka telah dilakukan modifikasi pada sistem AC tersebut dengan mengganti fungsi evaporator menjadi box Cooled EnergiStorage (CES). Pada modifikasi ini fungsi AC digabungkan dengan AHU dengan memanfaatkan fungsi evaporator sebagaisumber pendinginannya, dimana evaporator dimasukkan kedalam box yang telah diisi air dengan volume 0,072 m3. Denganmenggunakan pompa, air dingin tersebut dialirkan ke AHU, selanjutnya dimanfaatkan sebagai pendingin ruangan.Pengujian dilakukan dengan membandingkan dua cara pengoperasian. Pertama, sistem AC dan AHU dioperasikan secarabersamaan, sedangkan cara kedua sistem AC dioperasikan untuk mendinginkan air di box CES sampai mencapai temperaturyang hampir sama seperti pada saat cara pertama. Selanjutnya sistem AC dimatikan dan AHU dioperasikan untukmendinginkan ruangan. Hasil yang diperoleh pada cara pertama adalah temperatur air di box CES mencapai sekitar 0,9oCdalam waktu pengujian selama 1 jam (interval pencatatan data setiap 10 menit) sedangkan temperatur ruangan mencapai12,9 oC dan penggunaan daya listriknya mencapai 0,8650 kWh. Pada cara kedua, temperatur air di box CES mencapaisekitar 0,5 oC pada selang waktu pengujian selama 30 menit. Setelah AC dimatikan dan AHU dioperasikan, ruangan hanyamampu didinginkan mencapai temperatur 17,8 oC dalam waktu 30 menit. Tetapi temperatur air di box CES mencapai 16,5 oCpada 10 menit pertama dan terjadi peningkatan yang sangat kecil pada menit-menit berikutnya. Penggunaan daya listrikdengan cara yang kedua ini menunjukkan terjadinya penghematan sebesar 0,4201 kW dibandingkan dengan cara pertama.
Pengaruh variasi jenis pasir sebagai media penyimpan panas terhadap performansi kolektor suya tubular dengan pipa penyerap disusun secara seri Ketut Astawa; Nengah Suarnadwipa
Jurnal Energi Dan Manufaktur Vol 9 No 2 (2016): Oktober 2016
Publisher : Department of Mechanical Engineering, University of Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (281.965 KB)

Abstract

Abstrak:Kolektor surya tubular dengan pipa penyerap yang disusun secara seri dengan menggunakan variasi jenis pasir sebagaimedia penyimpanan panas dimana fluida kerja yang mengalir pada susunan kolektor surya tubular secara seri mendapatpemanasan yang berulang sepanjang pipa penyerap sehingga diharapkan panas yang diserap oleh fluida lebih maksimal.Rancangan alat uji ini terdiri dari 3 kolektor surya dimana kolektor pertama dengan variasi jenis pasir pantai warna hitam,kolektor kedua dengan variasi jenis pasir pantai warna putih, kolektor ketiga dengan variasi jenis pasir pantai warna hitammengkilap. Secara keseluruhan kolektor surya ini terdiri dari masing-masing tiga buah modul, dimana setiap modul darimasing-masing kolektor terdiri dari satu buah pipa penyerap. Metode pengujian yang digunakan adalah pengujianexperimental terhadap rancang bangun kolektor surya tersebut untuk mendapatkan performansi terbaik dari variasi jenispasir sebagai media penyimpan panas.Efisiensi aktual (?a) kolektor surya tubular dengan pipa penyerap yang disusunsecara seri dengan menggunakan variasi jenis pasir sebagai media penyimpanan panas paling tinggi diperoleh pada kolektorsurya tubular dengan variasi jenis pasir pantai warna hitam mengkilap dibandingkan dengan efisiensi aktual (?a) kolektorsurya tubular dengan variasi jenis pasir pantai warna hitam dan kolektor surya tubular dengan variasi jenis pasir pantai warnaputih.Kata kunci: Kolektor surya tubular yang disusun seri, variasi jenis pasir, efisiensi aktual kolektorAbstract:Tubular solar collectors with absorber pipes arranged in series using variations of type of sand as a heat storage medium inwhich the working fluid flowing in the composition of tubular solar collectors in series get repetitive heating along the pipelineso hopefully absorbing the heat absorbed by the fluid more leverage. The design of this test equipment consists of three solarcollectors, the first collector with variations black sand beaches, the second collector with variations white sand beaches, thethird collector with variations shiny black sand beaches. Overall solar collector consists of three pieces each of the modules,the module of each collector consists of an absorber pipes. Testing method used was experimental testing of the solarcollector design is to get the best performance from variations of type of sand as a heat storage medium. The actualefficiency (?a) tubular solar collectors with absorber pipes arranged in series using variations of type of sand as a heatstorage medium highest obtained in tubular solar collectors with variations shiny black sand beaches compared to the actualefficiency (?a) tubular solar collectors with variations black sand beaches and tubular solar collectors with variations whitesand beaches.Keywords: Tubular solar collectors arranged in series, variations of type of sand, the actual efficiency of the collector
Pengaruh Penempatan Sirip Berbentuk Segitiga Yang Dipasang Secara Aligned Dan Staggered Terhadap Performansi Kolektor Surya Pelat Datar Ketut Astawa; I Nengah Suarnadwipa
Jurnal Energi Dan Manufaktur Vol 8 No 2 (2015): Oktober 2015
Publisher : Department of Mechanical Engineering, University of Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (448.236 KB)

Abstract

Abstrak:Energi surya adalah jenis energi terbarukan yang umum digunakan karena ketersediaannya yang sangat besar. Teknologi pengolah energi surya, salah satunya adalah kolektor surya. Kolektor surya pada umumnya, menggunakan laju aliran massa udara yang secara parallel melewati pelat penyerap. Udara yang masuk inlet akan melewati pelat penyerap dan langsung keluar melalui outlet. Penelitian ini dilakukan untuk membandingkan pengaruh penempatan sirip berbentuk segitiga yang dipasang secara alignedyang mengarah ke atas pada bagian atas pelat penyerap dan staggeredyang mengarah ke bawah pada bagian bawah dari pelat penyerap sehingga akan terjadi aliran udara secara turbulen di dalam kolektor dan dengan penambahan sirip segitiga ini juga dapat memperluas daerah penyerapan panas pada pelat penyerap kolektor surya yang secara langsung memperluas permukaan perpindahan panas dari pelat penyerap ke fluida kerja yang nantinya diharapkan mampu menghasilkan temperatur keluar kolektor yang lebih tinggi dan meningkatkan performansi kolektor surya pelat datar.Penelitian ini dilakukan secara eksperimen, sebagai variable bebas dalam penelitian ini adalah intensitas radiasi matahari dan variabel terikatnya adalah energi berguna dan efisiensi kolektor surya pelat datar.Dari hasil pembahasan penempatan sirip berbentuk segitiga pada kolektor surya pelat datar yang dipasang secara staggered menghasilkan energi berguna dan efisiensi yang lebih besar dibandingkan dengan kolektor surya yang dipasang secara aligned. Dilihat dari rata-rata hariannya energi berguna untuk kolektor bersirip aligned adalah 153.01 Watt dan untuk kolektor bersirip staggered sebesar 157.42 Watt, sedangkan untuk efesiensinya pada kolektor surya bersirip aligned adalah 37.94% dan untuk kolektor bersirip staggered42.12 %.Kata kunci : Performansi kolektor surya pelat datar, sirip segitiga aligned, sirip segitiga staggeredAbstract:Solar energy is a type of renewable energy that is commonly used because of its availability is very large. Processing technology of solar energy, one of which is a solar collector. Solar collectors in general, using the mass flow rate of air which passes parallel absorber plates. Incoming air inlet will pass through the absorber plate and directly out through the outlet. This study was conducted to compare the effect of the placement of a triangular fin mounted aligned that leads upward to the top of the absorber plate and staggered downward at the bottom of the absorber plate so that it will occur in the turbulent air flow in the collector and with the addition of a triangular fin This can also extend the area of heat absorption in the absorber plate solar collector that directly expand the surface area of heat transfer from the working fluid to the absorber plate which hopefully will be able to produce out collector temperature is higher and improve performance of flat plate solar collector.This research was carried out experimentally, as the independent variable in this study is the intensity of solar radiation and the dependent variable is useful energy and efficiency flat plate solar collector.From the discussion, a triangular fin placement on flat plate solar collectors are mounted in staggered generate useful energy and greater efficiency than the solar collectors are biggest aligned. Judging from the average daily useful energy for finned aligned collector is 153.01 Watt and for collectors finned staggered at 157.42 Watt, while for its efficiency in solar collector finned aligned is 37.94% and for the collector finned staggered 42.12%.Keywords: Performance flat plate solar collectors, triangular fins aligned, triangular finsstaggered
Pengaruh Beban Pemanasan Air Terhadap Efisiensi Kondensor Pada Sistem Heat Pump I Nengah Suarnadwipa; Made Ricki Murti
Jurnal Mettek: Jurnal Ilmiah Nasional dalam Bidang Ilmu Teknik Mesin Vol 3 No 2 (2017)
Publisher : Program Studi Magister Teknik Mesin Universitas Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Pada penelitian ini, variabel yang diteliti adalah laju aliran volume air yang merupakan beban pemanasan air di kondensor pada sistem heat pump. Sistem ini menggunakan fluida kerja R-134a. Kondensor yang digunakan tipe concentric tube dan evaporator dari tipe fin tube. Pengukuran yang dilakukan meliputi pengukuran laju aliran volume refrigeran, pengukuran daya input kompresor dengan wattmeter, temperatur refrigeran di setiap titik kondisi dan temperatur air sisi masuk dan keluar kondensor. Dari hasil penelitian diperoleh temperatur pemanasan air menurun, laju panas kondensor pada sisi refrigeran dan sisi air mengalami penurunan dengan meningkatnya laju aliran volume air (beban pemanasan air) dan efisiensi kondensor yang dihasilkan maksimum terjadi pada beban pemanasan 4 liter/menit sebesar 84%. In this study, it was investigated the water volume rate of water heating load in the condenser on the heat pump system. The heat pump system uses R-134a as the working fluid. In this experiment, it is used the concentric tube type condenser and the fin tube type evaporator. The measurements conducted include measurement of refrigerant volume flow rate, compressor input power with wattmeter, refrigerant temperature at every point of condition and inlet-outlet condenser water temperature. As the result, it showed that the water heating temperature decreased, the condenser water side and refrigerant side heat rate decreased with the increasing of the water volume flow rate (water heating load) and the maximum condenser efficiency of about 84% is obtained at 4 liter / minute heating load.
Analisa Perpindahan Panas Pada Heater Tank FASSIP - 01 Mahran Noufal; I Gusti Bagus Wijaya Kusuma; I Nengah Suarnadwipa
Jurnal Mettek: Jurnal Ilmiah Nasional dalam Bidang Ilmu Teknik Mesin Vol 3 No 1 (2017)
Publisher : Program Studi Magister Teknik Mesin Universitas Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

FASSIP-01 adalah sebuah piranti analisa pengembangan metode sirkulasi alamiah yang bertujuan dasar untuk mengedepankan aspek keamanan teknologi struktur untuk PLTN. Prototype FASSIP-01 memiliki beberapa komponen penting, salah satunya adalah Tabung Heater. Tabung ini berfungsi sebagai tabung induk pemanas untuk memanaskan pipa utama FASSIP – 01 yang melintas di dalamnya untuk kemudian terkena efek buoyancy dan bergerak mengikutin untaian. Penelitian FASSIP-01 telah dilakukan di Badan Tenaga Nuklir Nasional (BATAN) namun data yang dihasilkan belum ditemukan yang meliputi temperatur dan kecepatan aliran fluida. Dikarenakan kurangnya data pembanding awal, penulis melakukan beberapa asumsi yang dipakai sebagai acuan daripada penelitian ini. Selanjutnya data hasil simulasi kondisi asumsi tersebut dianalisa dan kemudian hasil simulasi dengan kondisi analisa menjadi hasil utama yang didapat dari penelitian ini. Dari penelitian yang dilakukan ditemukan bahwa telah terjadi peningkatan unjuk kerja yang meliputi laju perpindahan panas dan efektivitas yang dihasilkan. Laju perpindahan panas yang dihasilkan apabila tanpa permukaan tambahan pada pipa menunjukkan hasil 55.760,56 Watt dan efektivitas 56,4 %, sedangkan jika ditambahkan permukaan berbentuk juring berjumlah 2 buah maka akan menghasilkan daya sebesar 64.150,86 Watt dan efektivitas sebesar 64,9 % dengan efisiensi sebesar 98%. FASSIP – 01 was an analysys loop that developed natural sirculation method purposed for leading safe and secure aspect on structure of nuclear power plant. The prototype of FASSIP – 01 had some important component of it, the one is Heater Tank. The tank was build as main heater to made main pipe of FASSIP – 01 heated, located inside of the tank that will affected with buoyancy and then flows following the loop. The research of FASSIP – 01 had been done at Indonesian Nuclear Researcher Agency (BATAN) but the result data was not completely found, included the temperature and real velocity of the flows. Caused by the less of main data that could be compared, we’ve made some assumption used for according to on this research. After all, the datas about simulation with assumption condition would be analyze and the result of simulation with real condition will be the main result as could as we got at this research. From this research, we could know that improvement of performance happened including heat transfer rate and effectivity. The heat transfer result if without the attachment of extended surface would be 55.760,56 Watt, dan the effectivity would be 56,4 %, at the other side if the attachment of extended surface with pie (segments) type with total amount is 2 was active so the heat transfer rate would be 64.150,86 Watt and the effectivity would be 64,9 % with the 98% efficiencies.
Fenomena Transport Heat Exchanger Sistem Untai Miftah Ayu Fauziah; I Gusti Bagus Wijaya Kusuma; I Nengah Suarnadwipa; Ni Made Dwidiani
Jurnal Mettek: Jurnal Ilmiah Nasional dalam Bidang Ilmu Teknik Mesin Vol 3 No 2 (2017)
Publisher : Program Studi Magister Teknik Mesin Universitas Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Heat exchanger sistem untai adalah suatu alat yang dibuat khusus untuk aliran satu-fasa dengan variabel diantaranya daya pemanas dan laju aliran fluida. Daya pemanas dalam untai berupa elemen pemanas air yang memiliki daya 1000 Watt. Heat exchanger sistem untai tersusun atas heater tank, cooling tank, dan pipa kaca (pyrex) yang membentuk sebuat siklus. Adapun fungsi dari masing-masing bagian yaitu, heater tank berfungsi sebagai media memanaskan alir dengan elemen pemanas hingga waktu yang telah ditentukan. Cooling tank berfungsi sebagai media mendinginkan air dimana pada cooling tank terdapat heat exchanger berupa coil and shell yang direndam dalam air atau kolam pendingin, di dalam heat exchanger fluida berupa air yang terlebih dahulu telah dipanaskan, air dipanaskan pada heater tank akan memberikan efek perubahan kerapatan fluida yang akan menyebabkan terjadinya pergerakan fluida yang disebabkan oleh efek buoyancy, yang tersusun atas pipa kaca dan membentuk sebuah siklus. Penelitian ini bertujuan untuk mengetahui kecepatan aliran fluida dalam heat exchanger sistem untai melalui simulasi ansys fluent dan menganalisa perpindahan kalor yang terjadi serta dapat mengetahui banyaknya kalor yang mampu dipertukarkan melalui metode perhitungan secara matematis. Dari hasil penelitian, analisa perhitungan, dan simulasi yang telah dilakukan dengan input running simulasi yaitu temperatur dan tekanan didapatkan output yaitu velocity aliran fluida sebesar 1,264 m/s. Adapun panas yang dapat dipertukarkan pada heater tank sebesar 2039,66 Watt dan hanya memiliki efektifitas sebesar 38%. Pada Cooling tank mampu mempertukarkan kalor sebesar11281,53 Watt dan memiliki efektifitas sebesar 84% serta jumlah heat transfer yang mampu disalurkan (NTU) sebesar 1,83. Heat exchanger strand system is a tool made specifically for single-phase flow with variables including heating power and fluid flow rate. Heating power in the strand is a water heater element that has 1000 Watt power. Heat exchanger strand system is composed of heater tanks, cooling tanks, and glass pipes (pyrex) that form a cycle. The function of each section is, heater tank serves as a medium to heat the flow with the heating element until the time specified. Cooling tank serves as a cooling water medium where the cooling tanks contain heat exchanger in the form of coil and shell soaked in water or cooling pool, in a heat exchanger fluid in the form of water that has first been heated, water heated on the heater tank will give effect fluid density change which will lead to fluid movement caused by the buoyancy effect, which is composed of a glass pipe and form a cycle. This study aims to determine the speed of fluid flow in the heat exchanger strand system through simulation Ansys fluent and analyze the heat transfer that occurs and can know the amount of heat that can be exchanged through mathematical calculation method. From the results of research, calculation analysis, and simulations that have been done with input running simulation ie temperature and pressure obtained output velocity fluid flow of 1,264 m / s. The heat that can be exchanged on the heater tank of 2039.66 Watt and only has the effectiveness of 38%. In Cooling tanks capable of exchanging heat of 11281.53 Watt and has an effectiveness of 84% and the amount of heat transfer that can be channeled (NTU) of 1.83.
Analisis Perpindahan Panas Pada Cooler Tank FASSIP - 01 Aprianto Tangkesalu; I Gusti Bagus Wijaya Kusuma; I Nengah Suarnadwipa
Jurnal Mettek: Jurnal Ilmiah Nasional dalam Bidang Ilmu Teknik Mesin Vol 3 No 1 (2017)
Publisher : Program Studi Magister Teknik Mesin Universitas Udayana

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

FASSIP-01 merupakan sebuah alat uji ekperimen yang dikhususkan untuk aliran satu-fasa dengan variabel parameter daya heater dan laju aliran pendingin di cooler. Pada sistem FASSIP-01 terdapat beberapa komponen penting salah satunya cooler tank. Cooler tank sendiri terdiri dari 2 bagian yaitu pipa refrigerator dan tabung cooler. Hasil eksperimen sementara yang telah dilakukan di BATAN dibagian cooler tank khususnya di pipa refrigerator, diperoleh perubahan temperatur yang meningkatkan dari keadaan awal, yang seharusya tidak boleh mengingat fungsi dan kerjanya sebagai pendingin. Penelitian ini ditujukan untuk menganalisis lebih dalam sistem perpindahan panas yang terjadi pada cooler tank melalui metode simulasi dan perhitungan matematis, untuk mengetahui seberapa besar temperatur fluida yang dapat diturunkan di pipa refrigerator yang akan menjadi fluida pendingin pipa utama di tabung cooler, sekaligus unjuk kerja daripada alat dan peningkatan kerja jika ada permukaan tambahan pada pipa utama di bagian dalam tabung cooler. Dari hasil analisis penelitian yang dilakukan ditemukan bahwa temperatur inlet-outlet di pipa refrigerator turun dari 260C menjadi 21,570C setelah terjadi proses pendinginan. Sementara dengan penambahan permukaan pada pipa utama tabung cooler menunjukkan adanya peningkatan kerja meliputi laju perpindahan panas, efektivitas dan NTU. Laju perpindahan panas yang dihasilkan tanpa permukaan tambahan sebesar 1116,68 Watt dengan efektivitas 51% dan NTU 0,71. Sementara dengan adanya permukaan tambahan berupa cincin rectangular sebanyak 10 buah menghasilkan laju perpindahan panas sebesar 1456 Watt dengan efektivitas sebesar 67% dan NTU 1,10 dengan efisiensi 82 %. FASSIP-01 is an experimental test equipment that dedicated to a single-phase flow with variable heater power parameters and coolant flow rate in the cooler. In FASSIP-01 system, there are several important components, one is a cooler tank. Cooler tank consists from refrigerator pipes and cooler tubes. The experimental cooler tank results that had been done in BATAN, especially in refrigerator pipes, the temperature was increased from the initial state, which is should not be happened as the functions and works as cooler. This study aimed to analyze the heat transfer systems that occur on the cooler tank through simulation methods and mathematical calculations, to determine how much fluid temperature can be descreased in the refrigerator pipes which will be the fluid coolant in the cooler tubes, and performance that will increase in system if there is extended surface on the main pipe inside of the cooler tubes. From the analysis of research conducted found that the temperature at the inlet-outlet refrigerator pipes is descreased from 26oC into 21,57oC after cooling process. The extended surface on the main pipe cooler tubes showed an increase of work includes the heat transfer rate, effectiveness and NTU. The resulting rate of heat transfer without extended surface at 1116.68 Watt with effectiness 51% and NTU 0.71. While the extended surface with the form of a rectangular fins with 10 pieces produces the heat transfer rate at 1456 Watt with effectiveness 67% and NTU 1.10 as the fins efficiency 82%.
ANALISIS UNJUK KERJA KOLEKTOR SURYA PELAT DATAR DENGAN PENAMBAHAN SIRIP BERLUBANG BERDIAMETER BEDA SEBAGAI NOSEL YANG DISUSUN SECARA STAGGERED Ketut Astawa; I N Suarnadwipa; I GN Tenaya; Agus Junianto
Jurnal Ilmiah Teknik Mesin POROS Vol 17, No 1 (2021): Jurnal Ilmiah Teknik Mesin Poros
Publisher : Program Studi Teknik Mesin Universitas Tarumanagara

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (725.626 KB) | DOI: 10.24912/poros.v17i1.15391

Abstract

The solar collector is a device that collects solar radiation and converts it into useful heatenergy. Several types of solar collectors include the parallel flow flat plate solar collector and theperpendicular flow absorber plate solar collector. Previous design of flat plate solar collectorperpendicular flow absorber plate usually uses plates with the same hole diameter. To improve theperformance of this solar collector, modifications have been made by adding perforated fins withdifferent diameters which are arranged staggeredly as an air flow channel or nozzle. The intendedmodification of nozzle diameter is to make the nozzle diameter size different from the large diameter nearthe inlet to the small diameter near the oulet and compared to the reverse nozzle position. Making thediameter of the nozzle near the inlet is larger than the diameter of the hole near the outlet aims to makethe mass flow of air passing through the hole near the inlet larger, so that the flow of air massesexperiences more heat transfer while the diameter of the hole near the outlet is made small is to reducethe mass flow of air which is wasted faster through the outlet channel. With the variation of the holediameter from large to small, it is expected that the heat transfer that occurs in the solar collector will bemore optimal, but it should also be seen in the reverse position. The research was carried outexperimentally. The results of his research show that the useful energy and efficiency of solar collectorswith large to small diameter slotted fins are higher than those with small to large diameter slotted fins.