ANALISIS KINERJA EVAPORATOR PADA SISTEM ORGANIC RANKINE CYCLE KAPASITAS 500KW Wahidin, Wahidin; Gaos, Yogi Sirodz; Wiradinata, Irvan
ALMIKANIKA Vol 1 No 1 (2019): Januari
Publisher : UNIVERSITAS IBN KHALDUN BOGOR

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32832/almikanika.v1i1.2010

Abstract

This research is observes an evaporator performance in the Organic Rankine Cycle (ORC) 500 kW power plant. The purpose of this research is to analyse the efficiency and performance the evaporator. The working fluid used in this ORC system is n-pentane (C5H12). Several parameters which were taken into consideration during the thermal calculation are: Thermodynamic; Properties of working fluid based on Refrop; and the ORC’s efficiency. Moreover, this research used Heat Transfer Research Inc (HTRI) in order to compare manual and software-based calculation. This calculation shows that 8,64 percent overdesign deviation (1741 tube by manual calculation while 1782 by software-base calculation). Data obtained for this research shows that the hot water circulation in the tube side has a mass flow of 28.828 kg/s, an inlet temperature of 164.99 C , an outlet temperature of 134.99 C . Meanwhile, in the shell side (n-pentane) has an inlet temperature of 91.61 C , an outlet temperature of 140.43 C and a mass flow 10.213 kg/s. The results show that the evaporator has an efficiency of 66.5 percent, Q hot water ( = 3632 kW, latent heat and sensible heat = 3886.95 kW.
EFEKTIFITAS PENGADAAN BARANG DAN JASA BADAN USAHA MILIK NEGARA (BUMN) MELALUI PROSES EVALUASI SISTEM GUGUR Wiradinata, Irvan; Gaos, Yogi Sirodz; Annisa, Annisa
ALMIKANIKA Vol 1 No 3 (2019): Juli
Publisher : UNIVERSITAS IBN KHALDUN BOGOR

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32832/almikanika.v1i3.2948

Abstract

Tujuan utama dari badan usaha milik Negara (BUMN) adalah untuk melayani masyarakat, namun BUMN tetap memiliki tujuan untuk memperoleh keuntungan (profit oriented). Penelitian ini bertujuan untuk meneliti proses pengadaan barang dan jasa di perusahaan BUMN yang menggunakan sistem gugur. Studi kasus dilaksanakan pada proses pengadaan salah satu proyek di PT Perusahaan Listrik Negara (PLN) Persero pada tahun 2019. Penelitian ini menunjukan bahwa proses evaluasi sistem gugur dapat menurunkan potensi keuntungan dari PLN. Hal ini dikarenakan calon kontraktor yang tidak lulus proses evaluasi sistem gugur yang diterapkan oleh PLN bisa saja memiliki pengalaman yang sesuai dan harga terendah. Oleh karena itu, sebaiknya proses evaluasi dititik beratkan kepada pengalaman yang sesuai dan harga terendah.Kata kunci : manajemen, pengadaan, proyek, evaluasi, tender.  
ANALISIS KESEIMBANGAN TERMAL AIR HEATER PADA PLTU BATU BARA 65 MW BUKIT ASAM Haraq, Muhammad Abdullah; Gaos, Yogi Sirodz; Wiradinata, Irvan
ALMIKANIKA Vol 4 No 2 (2022): April
Publisher : UNIVERSITAS IBN KHALDUN BOGOR

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32832/almikanika.v4i2.7052

Abstract

ABSTRAKPembangkit listrik tenaga uap (PLTU) yang menggunakan energi fosil untuk pembangkit listrik di Indonesia masih mendominasi khususnya memanfaatkan fosil batu bara untuk menjadi bahan bakar utama pada pembangkit listrik tenaga uap, namun karena bahan bakar fosil tidak termasuk kedalam energi yang terbarukan maka penggunaannya harus dengan bijak serta menekankan pada efisiensi yang maksimal dalam penggunaannya. Salah satu alat yang digunakan adalah Air Heater, Air Heater merupakan peralatan bantu dalam PLTU batu bara untuk meningkatkan efisiensi, AirHeater pada PLTU digunakan untuk memanaskan udara pembakaran dan meningkatkan proses pembakaran. Pemahaman tentang perpindahan kalor dan laju aliran di daerah tube dan dinding tube perlu dilakukan. Sehingga penelitian ini bertujuan untuk menentukan kesetimbangan panas pada airheater. Metode Penelitian ini dilakukan secara kuantitatif dengan menggunakan data desain dan data aktual. Analisis dilakukan dengan menggunakan data katakteristik perubahan temperatur TC-IN dan TC-OUT panas gas buang serta TC-IN dan TC-OUT udara lingkungan. Hasil penelitian menujukan bahwa perbandingan kesetimbangan panas airheater untuk Perhitungan Perpindahan Panas keseluruhan (MW) dengan menggunakan data aktual menunjukan hasil Dan nilai efisiensi sebesar ɳ = 51 % sedangkan hasil dari data desain dan nilai efisiensi sebesar ɳ = 67 % .Kata kunci : Air Heater; Kesetimbangan termal; Pembangkit listrikABSTRACTSteam power plants (PLTU) that use fossil energy for power generation in Indonesia still dominate, especially using coal fossil fuels to become the main fuel in steam power plants, but because fossil fuels are not included in renewable energy, their use must be used wisely and emphasizes maximum efficiency in its use. One of the tools used is Air Heater, Air Heater is auxiliary equipment in coal-fired power plants to increase efficiency, AirHeater in power plants is used to heat combustion air and improve combustion processes. An understanding of heat transfer and flow rates in the tube and tube wall areas needs to be done. So this research aims to determine the heat balance of the air heater. Method This research was conducted quantitatively using design data and actual data. Analyzes were performed using TC-IN and TC-OUT temperature changes in flue gas heat and environmental air TC-IN and TC-OUT. The results of the study show that the heat balance of the air heaters for the calculation of the overall heat transfer (MW) by using the actual data shows the results and efficiency value of ɳ = 51% while the results of the design data and an efficiency value of ɳ = 67%Keywords : Air Heater; power plants; thermal equilibrium analysis
Analisis Kinerja Air Heater pada PLTU batubara 65 MW Bukit Asam Ahmad, Haris; Gaos, Yogi Sirodz; Wiradinata, Irvan
ALMIKANIKA Vol 4 No 2 (2022): April
Publisher : UNIVERSITAS IBN KHALDUN BOGOR

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32832/almikanika.v4i2.7129

Abstract

ABSTRAK Air heater adalah salah satu komponen dalam PLTU yang bekerja dengan memanaskan  gas buang (flue gas) sisa pembakaran pada boiler dan menyuplainya kembali ke dalam boiler untuk pembakaran. Sesuai dengan fungsinya dalam peningkatan efisiensi kerja dalam siklus perpindahan panas, maka peranan air heater begitu penting. Karena mengurangi penggunaan energi serta menghemat kerja boiler dalam memanaskan air menjadi uap, hal ini diharapkan untuk mendapatkan pembakaran sempurna di ruang bakar. Maka dari itu analisa perpindahan energi dan peningkatan efisiensi kinerja pada air heater perlu dilakukan. Sehingga penelitian ini bertujuan untuk mencari koefisien perpindahan panas menyeluruh, efektivitas serta penghambat kinerja pada air heater. Metode penelitian yang digunakan adalah analisis dan pengolahan data komisioning. Hasil penelitian yang didapatkan koefisien perpindahan panas menyeluruh yang terjadi sebesar 244.729 kW, nilai efektivitas sebesar 0.7703 dan penghambat kinerja yaitu terjadinya kebocoran aliran flue gas dan fresh air. Kata kunci :  air heater; kinerja; pembangkit listrik. ABSTRACT Air heater is one component in a power plant that works by heating the flue gas (combustion flue) remaining combustion in the boiler and supply it back into the boiler for combustion. In accordance with its function in increasing work efficiency in the heat transfer cycle, the role of the air heater is so important. Because it reduces energy use and saves boiler work in heating water to steam, this is expected to get perfect combustion in the combustion chamber. Therefore an analysis of energy transfer and an increase in the efficiency of the performance of the air heater needs to be done. So this study aims to find the overall heat transfer coefficient, effectiveness and performance inhibitors on the air heater. The research method used is the analysis and processing of commissioning data. The results of the study found that the overall heat transfer coefficient is 244,729 kW, the effectiveness value is 0.7703 and the performance inhibitors are flue gas leakage and fresh air. Keywords : air heater; performents; power plants.
Analisis Eksergi Kondensor Pada Pltu Batu Bara Kapasitas 65 Mw Bukit Asam Anggara, Egi Robby; Gaos, Yogi Sirodz; Wiradinata, Irvan
ALMIKANIKA Vol 4 No 1 (2022): Januari
Publisher : UNIVERSITAS IBN KHALDUN BOGOR

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32832/almikanika.v4i1.7131

Abstract

ABSTRAK Analisis eksergi kondensor pada pltu batu bara kapasitas 65 mw bukit asam kebutuhan energi semakin meningkat, sumber energi untuk pembangkit listrik tenaga uap dapat dimanfaatkan di Indonesia. sayangnya sumber energi di negara ini juga menipis. Meskipun pembangkit listrik tenaga uap (PLTU) telah berkembang, itu adalah pembangkit listrik yang menggunakan tenaga uap batubara untuk meminimalkan penggunaan bahan bakar, tetapi masih di beberapa bagian ada ledakan sempurna yang ditakuti karena banyak sumber energi yang terbuang sehingga Analisis diperlukan agar setiap energi yang keluar dapat diketahui dan meminimalkan kerugian yang terbuang terutama pada komponen turbin turbin pada kondensor PLTU dapat ditinjau sebagai ketidak sempurnaan pada sistem. Sebuah sistem tidak mungkin sempurna atau tidak ada losses sama sekali karena proses nya yang terus menerus menjadikan sebuah sistem tersebut menghasilkan energi yang terbuang pada saat proses berlangsung. Losses terbesar terjadi pada pengambilan data ke 30  yaitu sebesar 43240,98  kW dengan losses rata rata sebesar 124401,6 kW Kata kunci :  Eksergi; Efisiensi; Kondensor; Kerugian; PLTU ABSTRACT Exergy analysis of the condenser at a coal power plant with a capacity of 65 MW Bukit Asam energy needs are increasing, energy sources for steam power plants can be utilized in Indonesia. Unfortunately, the energy resources in this country are also running low. Although the steam power plant (PLTU) has developed, it is a power plant that uses coal steam power to minimize the use of fuel,  but still in some parts there is a perfect explosion that is feared because many sources of energy are wasted so Analysis is needed so that every energy that comes out can be known and minimize wasted losses, especially in the turbine components of the PLTU condenser, which can be viewed as imperfections in the system. A system may not be perfect or there are no losses at all because the continuous process makes a system produce wasted energy during the process. The biggest losses occurred in the 30th data collection, which was 43240.98 kW with an average losses of 124401.6 kW Keywords : Condenser; Exergy; Efisiensi; losses; PLTU 
Analisis Eksergi Air Heater Pada PLTU Batu Bara 65 MW Bukit Asam Thullah, Asep Hidayat; Gaos, Yogi Sirodz; Wiradinata, Irvan
ALMIKANIKA Vol 4 No 3 (2022): Juli
Publisher : UNIVERSITAS IBN KHALDUN BOGOR

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32832/almikanika.v4i3.7132

Abstract

ABSTRAK Analisis Eksergi pada pembangkit listrik tenaga uap perlu dilakukan untuk menganalisis Eksergi serta memberikan informasi untuk meningkatkan nilai efisien pada Air Heater. Penelitian dilakukan dilab Enegi Program Studi Teknik Mesin Universitas Ibn Khaldun Bogor. Alat yang digunakan yaitu : preassure gauge, preassure transmiter, pompa, Gas analyzer, Solenoid valve, Expantion joint, Expantion joint, Computer personal. Dan bahan : Tube Sheet, Tube, Deeflacting, Baffle, Hopper. Analisa Eksergi Air Heater yaitu menghitung nilai Hot Steam dan Cold Steam, dilanjut dengan menentukan nilai Availability Exergy, Availability Work dan Eksergi loss. untuk mengetahhui nilai Eksergi loss yaitu dengan menjumlahkan terlebih dahulu dari nilai yang sudah dihitung yaitu,  nilai Availability Exergy dan Availability Work. Setelah mengetahui nilai dari Availability Exergy, Availability Work dan Eksergi loss maka dapat menentukan nilai efisiensi. Nilai keluaran dan masukan pada Air Heater Hot Stream sebesar 662,86 kJ/kg, Cold Stream sebesar 568,48 kJ/kg, Availability Exergy sebesar 101582,96 KW, Availability Work  sebesar 44345,33 KW, vailability Work  sebesar 47927,38 KW, Eksergi loss sebesar  KW. Dan efisiensi yang didapat yaitu sebesar 79%. Kata kunci :  Air Heater; analisis eksergi; efisiensi ABSTRACT Exergy analysis in steam power plants needs to be done to analyze the exergy and provide information to increase the efficient value of the air heater. The research was conducted in the Enegi Lab in the Mechanical Engineering Study Program at the University of Ibn Khaldun Bogor. The tools used are : preassure gauge, preassure transmiter, pompa, Gas analyzer, Solenoid valve, Expantion joint, Expantion joint sealing, Computer personal. Dan bahan : Tube Sheet, Tube, Deeflacting, Baffle, Hopper. Air Heater Exergy Analysis is calculating the value of Hot Steam and Cold Steam, followed by determining the value of Availability Exergy, Availability Work and Exergy loss. To find out the value of exergy loss, that is by adding up in advance the calculated value, namely the availability of Exergy and Availability Work. After knowing the value of Availability Exergy, Availability Work and Exergy loss, it can determine the value of efficiency. Output and input values at Hot Stream Air Heater of 662.86 kJ / kg, Cold Stream of 568.48 kJ / kg, Availability Exergy of 101582,96 KW, Availability Work  of 44345,33 KW, vailability Work  of 47927,38 KW, Exergy loss of 9310.25 KW. And the efficiency obtained is 79%. Keywords : Air Heater; exergy analysis; efficiency.