PERILAKU LEKATAN TULANGAN POLOS DAN TULANGAN ULIR PADA STRUKTUR BETON SERAT KAYU Karimah, Rofikatul
Media Teknik Sipil Vol 10, No 2 (2012): Agustus
Publisher : Department of Civil Engineering, Faculty of Engineering, University of Muhammadiyah Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (73.197 KB) | DOI: 10.22219/jmts.v10i2.1794

Abstract

Rofikatul KarimahFakultas Teknik Jurusan Teknik Sipil Universitas Muhammadiyah MalangAlamat Korespondensi : Jl. Raya Tlogomas 246 Malang 65144, IndonesiaKarimah@umm.ac.idABSTRACTIn addition wood powder residual sawmill.the concrete will cause a change in behaviorjuxtaposition between concrete and reinforcement steel reinforcement material either plain orreinforcement thread.The research this studyFiber is used sawmill waste wood fiber with content0%, 0.5%, 1% and 1.5% of the volume of concrete as a comparison is also made of concretewithout fibers.Specimens used were silinder30 cm x 15 cm were 12 specimens for compressive strengthtesting and 24 specimens for testing strong adhesion. By using reinforcement thread diameter D10mm and 10 mm reinforcment glace.From the research of the study isstudy iscompressive strengthwith a mixture of sawdustdeclineswith the powder in each variation the capability of strong stickbetween reinforcing steel and concreteplain wood fiber and strong adhesion between reinforcment glace stee land concrete screw woodfiber show that the strong ability adhesion reinforcment thread more thanreinforcment glace.Whilemore of fibers in the concrete mix variation, the lower the magnitude of the strong adhesion betweenthe concrete and reinforcement plain tacky.Keywords : Concrete, sawdust, compressive strength ,strong adhesive
PEMBUATAN BETON POROUS DENGAN MATERIAL GEOPOLIMER Karimah, Rofikatul; Prasojo, Akbar
Media Teknik Sipil Vol 17, No 1 (2019): Februari
Publisher : Department of Civil Engineering, Faculty of Engineering, University of Muhammadiyah Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (294.11 KB) | DOI: 10.22219/jmts.v17i1.7535

Abstract

Meningkatnya luas daerah yang ditutupi oleh perkerasan dengan pembangunan permukiman seperti halnya di perkotaan dapat mengakibatkan waktu berkumpulnya air menjadi jauh lebih pendek, dengan berkurangnya kesempatan air hujan berinfiltrasi ke dalam tanah, maka limpasan permukaan air hujan akan menimbulkan genangan bahkan banjir pun  dapat terjadi pula. Dalam upaya mengantisipasi hal tersebut, maka diperlukan penerapan mengenai drainase permukiman yang berwawasan lingkungan, seperti pembuatan perkerasan beton porous, sebatas untuk konstruksi non struktural seperti parkir kendaraan, trotoar, lapangan, dll. Perkembangan muktahir yang menjanjikan saat ini adalah penggunaan abu terbang sepenuhnya sebagai pengganti semen Portland lewat proses yang disebut polimerisasi anorganik (geopolimer). Diharapkan dari pembuatan beton porous dengan material geopolimer ini selain dapat menyerap air dengan cepat juga memiliki kekuatan mekanik yang sama dengan beton pada umumnya. Metode penelitian ini bersifat eksperimen dengan mencari mix design geopolimer yang paling tepat dari benda uji silinder diameter ukuran 7,5 cm dan tinggi 15 cm. Penelitian menggunakan campuran bahan pengganti semen Portland menggunakan material geopolimer pada benda uji silinder dan dibuat variasi prosentase 10%, 15%, 20%, 25% dan 30%. Berdasarkan hasil uji diperoleh variasi campuran geopolimer optimum pada 29% dengan kuat tekan beton 11 N/mm2 dan porositas beton 14%. Perlu ditemukan bahan tambah (Admixture) untuk mendapatkan kuat tekan, daya serap air, dan workability yang diinginkan pada pembuatan beton porous dengan material geopolimer.
PENGARUH PENGGUNAAN FOAM AGENT TERHADAP KUAT TEKAN DAN KOEFISIEN PERMEABILITAS PADA BETON Karimah, Rofikatul
Media Teknik Sipil Vol 15, No 1 (2017): Februari
Publisher : Department of Civil Engineering, Faculty of Engineering, University of Muhammadiyah Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (458.638 KB) | DOI: 10.22219/jmts.v15i1.4492

Abstract

Penelitian tentang penambahan foam agent pada beton bertujuan untuk mengetahui pengaruh yang diakibatkan oleh pemberian foam agent dengan variasi campuran terhadap pengujian kuat tekan dan pengujian permeabilitas pada beton.Bahan-bahan campuran beton yang dipakai adalah semen gresik PC type 1, pasir dengan batas gradasi zone 1, dan foam yang dihasilkan antara air dan foam agent dengan perbandingan 40 : 1. Variasi penambahan foam pada tiap campuran adalah 0%, 20%, 40%, 60%,dan 80%.Pengaruh penambahan foam agent terhadap kuat tekan semakin lemah. Kuat tekan rata-rata yang dihasilkan pada penambahan foam 0%, 20%, 40%, 60% dan 80% masing-masing menghasilkan kuat tekan rata-rata sebesar 21,68 Mpa, 7,92 Mpa, 4,53 Mpa, 0,75 Mpa dan 0,38 Mpa. Dan pengaruh penambahan foam agent terhadap uji permeabilitas menyebabkan koefisien permeabilitas yang dihasilkan semakin besar.
BATAKO LUMPUR LAPINDO SEBAGAI ALTERNATIF MATERIAL PASANGAN DINDING Karimah, Rofikatul
Media Teknik Sipil Vol 10, No 1 (2012): Februari
Publisher : Department of Civil Engineering, Faculty of Engineering, University of Muhammadiyah Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (169.399 KB) | DOI: 10.22219/jmts.v10i1.1214

Abstract

Block made of mud is a building material used in making wall for building that is made fromsand, cement, and fly ash using certain percentage mud in sand. This research aimed to know theeffect of the use of lapindo mud towards the compressive strength, the absorption of block waterwith the mud dosage in sand are: 0%, 10%, 20%, 30%, and 40%. This research was an experimentalresearch; each design was made in size 10x20x40 cm using 5% of fly ash and without fly ash.The result of this research showed that the highest compressive strength was raised in 10%mud in sand with 5% fly ash that was 195 kg/cm2 or increased about 3.44 kg/cm2 within increasingpercentage about 10.651% towards the compressive of block without lapindo mud with 5% of flyash, and was included in class I quality of block. While for the 30% and 40% mud percentage islower compared with normal compressive strength of block. The test result of water absorption oflapindo mud block showed the higher value than 20% for lapindo mud block with 5% fly ash, inframing the mud blocks as the wall, those blocks need to be soaked first because the absorptionvalue of block is higher than 20%. Lapindo mud block without 5% fly ash has bricks water absorptionless than 20%, while in framing those bricks, they don’t need to be soaked because the absorptionof brick if lower than 20%. By using fly ash in mud block, we can get the higher compressivestrength and the lower water absorption.Keyword: Porong Mud, Block, Fly Ash, Compressive Strength, Absorption
KUAT LENTUR DINDING PANEL BETON BUSA DENGAN PERKUATAN WIREMESH Rommel, Erwin; Rusdianto, Yunan; Karimah, Rofikatul
Media Teknik Sipil Vol 18, No 1 (2020): Februari
Publisher : Department of Civil Engineering, Faculty of Engineering, University of Muhammadiyah Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22219/jmts.v18i1.11099

Abstract

Permasalahan energi dan lingkungan menjadi issue utama yang terjadi di negara-negara maju dan negara yang sedang berkembang tidak terkecuali di Indonesia. Kondisi geografis negara Indonesia yang terletak pada iklim tropis dan sebagian besar dilewati wilayah gempa, maka diperlukan desain bangunan yang dirancang selain tahan gempa juga harus memiliki konsep bangunan hemat energi. Bangunan tahan gempa dan hemat energi adalah impian bangunan dimasa mendatang, dimana dibutuhkan bangunan yang ringan, sifat insulasi yang baik, tata ruang optimal, serta bangunan yang mampu membangkitkan dan memanfaatkan energi pada lingkungan sekitar menjadi energi listrik, seperti solar cell, tiupan angin, dan air hujan. Dinding panel beton busa menjadi salah satu alternatif selain bobotnya ringan, pemasangannya cepat dan dapat diproduksi massal dipabrik. Dinding panel berukuran (900x300x80) mm dibuat dengan campuran semen dan pasir 1:2,75 faktor air semen 0,425 dan 2% foam agent sebanyak 15 (lima belas) unit. Setiap 3 (tiga) benda uji dibuat dengan dinding panel tanpa perkuatan (PD), dinding panel diberi styrofoam pada bagian tengah (PDS), dinding panel dengan serat ijuk (PDF), dinding panel dengan wiremesh 4 mm (PDM) dan dinding panel dengan wiremesh 4 mm dan styrofoam (PDMS). Pengujian lentur dilakukan dengan metode four-point-bending berdasarkan SNI-1441-2011 dengan mengamati beban retak, beban ultimit, displacemen dan pola retak yang terjadi. Hasil pengujian diperoleh bahwa kuat lentur dinding panel yang memakai wiremesh meningkat hingga enam kalinya, sedangkan kekakuan lenturnya meningkat dua kali dibandingkan dengan panel dinding tanpa wiremesh. Pola retak yang terjadi pada dinding panel dengan wiremesh menghasilkan penyebaran retak yang lebih merata dengan keruntuhan lentur yang bersifat daktail, sedangkan dinding panel yang tanpa perkuatan keruntuhan lentur bersifat getas.
PENGARUH BOTTOM ASH SEBAGAI PENGGANTI PASIR DAN LIMBAH KARBIT SEBAGAI BAHAN TAMBAH SEMEN TERHADAP BERAT JENIS, KUAT TEKAN, DAN ABSORBSI BATAKO Ali, Nur; Karimah, Rofikatul; E.Meiyanto, H.
Media Teknik Sipil Vol 12, No 1 (2014): Februari
Publisher : Department of Civil Engineering, Faculty of Engineering, University of Muhammadiyah Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22219/jmts.v12i1.2046

Abstract

PENGARUH BOTTOM ASH SEBAGAI PENGGANTI PASIR DANLIMBAH KARBIT SEBAGAI BAHAN TAMBAH SEMENTERHADAP BERAT JENIS, KUAT TEKAN, DAN ABSORBSIBATAKONur Ali1, Rofikatul Karimah2 , H. E.Meiyanto31,2,3 Jurusan Teknik Sipil Fakultas Teknik – Universitas Muhammadiyah MalangAlamat korespondensi : Jalan Raya Tlogomas 246 Malang 65144Email: rofikatulkarimah@gmail.comABSTRACTBasically concrete brick is formed from cement, sand and water, than a breakthroughmade in manufacturing of concrete brick with the utilization of wastes which have no economicvalue are also widely available in the environment than is waste of bottom ash an carbide. In thisresearch, a normal concrete brick consist of cement, san, and water which given variation ofcarbide waste ranging from 10%, 20%, and 30%, afterwards a replacement of sand by bottomash is made with a given variation of carbide waste 10%, 20%, and 30%. Result of the researchthat applying sand as subtle aggregate and waste of carbide as additional material for cementgets the best result on the variation of carbide waste 30% with strength of compression 69,10MPa and 3,58% absorption capacity, it is better rather than normal concrete brick on the variationof carbide waste 0% with compressive strength of 48,74 MPa and 5,49 absorption capacity.After wards, by doing replacement of sand with bottom ash as subtle aggregate and addedwaste carbideas its variations is obtained the best results in the variation of carbide waste 30%with compressive strength 52,37 MPa and 6,92 of absorption capacity better rather than 0% ofvariation carbide waste with strength of compession 19,64 MPa and 12,01 of absorption capacity.Keyword: Concrete Brick, bottom ash, waste carbide.
KAJIAN PENGGUNAAN COPPER SLAG SEBAGAI AGREGAT HALUS BETON Karimah, Rofikatul
Media Teknik Sipil Vol 14, No 2 (2016): Agustus
Publisher : Department of Civil Engineering, Faculty of Engineering, University of Muhammadiyah Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22219/jmts.v14i2.3710

Abstract

Penggunaan copper slag sebagai bahan pengganti sebagian agregat halus karena copper slag memiliki bentuk dan gradasi yang menyerupai pasir alam. Bentuk fisik copper slag yaitu berbentuk pipih dan runcing (tajam) dan sebagian besar mengandung oksida besi dan silikat serta mempunyai sifat kimia yang stabil. Komposisi kimia copper slag terdiri dari Fe2O3, SiO2, CaO, Al2O3. Penelitian ini dilakukan untuk mengetahui pengaruh penggunaan copper slag sebagai pengganti sebagian agregat halus terhadap berat isi, kuat tekan, dan kuat tarik belah beton dengan variasi penggunaan copper slag sebesar 0%, 20%, 40%, 60%, 80% dan 100% dari volume agregat halus. Hasil penelitian menunjukan bahwa penggunaan copper slag dapat meningkatkan berat isi, kuat tekan dan kuat tarik belah beton. Dari hasil pengujian, semakin bertambah variasi pemberian copper slag maka semakin bertambah pula berat isi beton tersebut. Kuat tekan tertinggi terjadi pada variasi 60% sebesar 35,73 MPa atau naik sekitar 22,32%. Dan untuk kuat tarik belah tertinggi terjadi pada variasi 60%  sebesar 3,12 MPa atau naik sekitar 5,76%.
Pemanfaatan Serbuk Kulit Kerang Sebagai Pengganti Agregat Halus Terhadap Kuat Tekan Beton Karimah, Rofikatul; Rusdianto, Yunan; Susanti, Desy Putri
Jurnal Teknik Sipil : Rancang Bangun Vol 6, No 1 (2020): April 2020
Publisher : Universitas Muhammadiyah Sorong

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (232.348 KB) | DOI: 10.33506/rb.v6i1.1146

Abstract

Sejumlah penelitian teknologi kontruksi terus dikembangkan dengan tujuan dapat menghasilkan teknologi kontruksi yang tepat guna. Salah satunya dengan memanfaatkan serbuk kulit kerang yang dihasilkan oleh 89 unit pengolahan kerang di Desa Campurejo, Gresik. Dari 1 unit pengelolahan kerang mampu memanen ±100 kg setiap minggunya. Dari kegiatan tersebut dapat menghasilkan limbah padat berupa serbuk kulit kerang yang cukup tinggi. Untuk mengurangi dampak lingkungan dan kesehatan yang disebabkan oleh limbah tersebut, maka dilakukan pemanfaatan limbah serbuk kulit kerang sebagai bahan pengganti agregat halus pada campuran beton. Penelitian ini dilakukan untuk mengetahui pengaruh penggunaan serbuk kulit kerang sebagai pengganti agregat halus terhadap kuat tekan beton. Variasi penggunaan serbuk yang digunakan sebesar 0%, 5%, 10%, 15%, 20%, 25%, dan 30% dari berat agregat halus dengan FAS 0,6. Hasil pengujian diperoleh nilai kuat tekan beton mengalami kenaikan pada prosentase 10% dan selanjutnya kuat tekan beton menurun seiring dengan pertambahan prosentase penggunaan serbuk kulit kerang. Sedangkan nilai absorbsi beton mengalami kenaikan pada prosentase 30% dari berat agregat halus.
BATAKO LUMPUR LAPINDO SEBAGAI ALTERNATIF MATERIAL PASANGAN DINDING Rofikatul Karimah
Media Teknik Sipil Vol. 10 No. 1 (2012): Februari
Publisher : Department of Civil Engineering, Faculty of Engineering, University of Muhammadiyah Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22219/jmts.v10i1.1214

Abstract

Block made of mud is a building material used in making wall for building that is made fromsand, cement, and fly ash using certain percentage mud in sand. This research aimed to know theeffect of the use of lapindo mud towards the compressive strength, the absorption of block waterwith the mud dosage in sand are: 0%, 10%, 20%, 30%, and 40%. This research was an experimentalresearch; each design was made in size 10x20x40 cm using 5% of fly ash and without fly ash.The result of this research showed that the highest compressive strength was raised in 10%mud in sand with 5% fly ash that was 195 kg/cm2 or increased about 3.44 kg/cm2 within increasingpercentage about 10.651% towards the compressive of block without lapindo mud with 5% of flyash, and was included in class I quality of block. While for the 30% and 40% mud percentage islower compared with normal compressive strength of block. The test result of water absorption oflapindo mud block showed the higher value than 20% for lapindo mud block with 5% fly ash, inframing the mud blocks as the wall, those blocks need to be soaked first because the absorptionvalue of block is higher than 20%. Lapindo mud block without 5% fly ash has bricks water absorptionless than 20%, while in framing those bricks, they don’t need to be soaked because the absorptionof brick if lower than 20%. By using fly ash in mud block, we can get the higher compressivestrength and the lower water absorption.Keyword: Porong Mud, Block, Fly Ash, Compressive Strength, Absorption
PERILAKU LEKATAN TULANGAN POLOS DAN TULANGAN ULIR PADA STRUKTUR BETON SERAT KAYU Rofikatul Karimah
Media Teknik Sipil Vol. 10 No. 2 (2012): Agustus
Publisher : Department of Civil Engineering, Faculty of Engineering, University of Muhammadiyah Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22219/jmts.v10i2.1794

Abstract

Rofikatul KarimahFakultas Teknik Jurusan Teknik Sipil Universitas Muhammadiyah MalangAlamat Korespondensi : Jl. Raya Tlogomas 246 Malang 65144, IndonesiaKarimah@umm.ac.idABSTRACTIn addition wood powder residual sawmill.the concrete will cause a change in behaviorjuxtaposition between concrete and reinforcement steel reinforcement material either plain orreinforcement thread.The research this studyFiber is used sawmill waste wood fiber with content0%, 0.5%, 1% and 1.5% of the volume of concrete as a comparison is also made of concretewithout fibers.Specimens used were silinder30 cm x 15 cm were 12 specimens for compressive strengthtesting and 24 specimens for testing strong adhesion. By using reinforcement thread diameter D10mm and 10 mm reinforcment glace.From the research of the study isstudy iscompressive strengthwith a mixture of sawdustdeclineswith the powder in each variation the capability of strong stickbetween reinforcing steel and concreteplain wood fiber and strong adhesion between reinforcment glace stee land concrete screw woodfiber show that the strong ability adhesion reinforcment thread more thanreinforcment glace.Whilemore of fibers in the concrete mix variation, the lower the magnitude of the strong adhesion betweenthe concrete and reinforcement plain tacky.Keywords : Concrete, sawdust, compressive strength ,strong adhesive