Claim Missing Document
Check
Articles

Found 12 Documents
Search

NoduViT: An Attention-Driven DeepLab–CustomViT Hybrid Model for Segmentation-Informed Multiclass Pulmonary Patch Classification Fachruddin Fachruddin; Yovi Pratama; Errissya Rasywir; Yessi Hartiwi; Jasmir Jasmir; Hastie Audytra; Marrylinteri Istoningtyas
Jurnal RESTI (Rekayasa Sistem dan Teknologi Informasi) Vol 10 No 5 (2026): October 2026
Publisher : Ikatan Ahli Informatika Indonesia (IAII)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29207/resti.v10i5.7124

Abstract

Lung cancer detection using CT imaging requires accurate lung segmentation and nodule classification. This study evaluates SegFormer configurations and hybrid CNN–Transformer models using the LIDC-IDRI dataset. Initial experiments showed that pretrained and from-scratch SegFormer models failed to detect target classes, while fine-tuning achieved IoU scores of 0.6628 and 0.6244 for the right and left lungs, respectively, with corresponding F1-scores of 0.7972 and 0.7688. However, nodule segmentation remained challenging (IoU 0), with limited improvement using a Nodule Loader (IoU 0.1487, F1 0.2589). Compared with recent models reporting Dice scores above 94%, SegFormer demonstrated lower segmentation performance. For classification, standalone ViT, ResNet, and DeepLab achieved accuracies of 72%, 61%, and 82%, respectively, whereas hybrid ResNet+ViT and DeepLab+ViT achieved 98% and 99.54%. Despite these improvements, class imbalance reduced minority-class nodule recall and weighted F1-scores. Overall, fine-tuned SegFormer effectively segments major lung structures but struggles with nodules, while hybrid CNN–Transformer classifiers achieve high accuracy yet require improved class balancing for reliable clinical generalization.
Usability Analysis of the POLRI Presisi Application Using Usability Testing and the System Usability Scale Andre Uldian Saragih; Jasmir Jasmir; Fachruddin Fachruddin
Journal of Computer Science and Informatics Engineering Vol 5 No 4 (2026)
Publisher : Ali Institute of Research and Publication

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55537/cosie.v5i4.1947

Abstract

This study aims to evaluate the usability of the PRESISI POLRI application based on users' perceptions and experiences. A quantitative survey approach was employed using usability indicators and the System Usability Scale (SUS). Data were collected through an online questionnaire involving 384 users of the PRESISI POLRI application. Data analysis was conducted using SPSS version 22, including validity, reliability, classical assumption tests, and multiple linear regression to examine the relationships between learnability, efficiency, memorability, errors, and user satisfaction. Meanwhile, SUS was used to assess overall perceived usability. The results indicate that all four usability variables have positive and statistically significant associations with user satisfaction, with a coefficient of determination (R²) of 0.623. The average SUS score was 44.09, classified as Grade F, Poor, and Not Acceptable. These findings indicate a low level of perceived usability, highlighting the need for improvements in ease of use, efficiency, navigation, and error handling to enhance the user experience.