Calculation Of Fetal Weight Estimation Displayed With TFT LCD Nadhia Regitasari; M. Ridha Mak'ruf; Endang Dian Setioningsih
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 2 No 1 (2020): January
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v2i1.4

Abstract

Fetal weight estimation during pregnancy is one of the beneficial ways to solve morbidity and death during labor problem. Manually, the fundal height is measured from the edge of the pubic symphysis to the top of the uterine fundus by following the arch of the uterus, using a measuring tape. The purpose of this study is to develop an easy way to count fetal weight estimation so midwives don’t have to count manually. The calculation of fetal weight estimation tool uses a variable resistor (potentiometer) as a sensor to measure the fundal height. Then it will be processed in microcontroller. The measurement results are fundal height and estimation fetal weight that will be displayed on the TFT LCD. Based on the results of measuring the fundus uterine height as much as 6 times against the measuring tool (ruler), there is no error in the device so it can be concluded that this tool can be used according to its function. This calculation of fetal weight estimation tool is portable and easy to use to help midwives count the fetal weight estimation quickly.
Design of Respiration Rate Meter Using Flexible Sensor Sarah Aghnia Miyagi; Muhammad Ridha Mak’ruf; Endang Dian Setioningsih; Tark Das
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 2 No 1 (2020): January
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v2i1.3

Abstract

Respiration rate is an important physiological parameter that helps to provide important information about the patient's health status, especially from the human respiratory system. So it is necessary to measure the human respiratory rate by calculating the number of respiratory frequencies within 1 minute. The respiratory rate meter is a tool used to calculate the respiratory rate by counting the number of breaths for 1 minute. The author makes a tool to detect human respiratory rate by using a sensor that detects the ascend and descend of the chest cavity based on a microcontroller so that the operator can measure the breathing rate more practically and accurately. Component tool contains analog signal conditioning circuit and microcontroller circuit accompanied by display in the form of LCD TFT. The results of measurement data on 10 respondents obtained an average error value, namely the position of the right chest cavity 6.6%, middle chest cavity 7.92%, and left chest cavity 6.85%. This value is still below the error tolerance limit of 10%. It can be concluded that to obtain the best measurement results, the sensor is placed in the position of the right chest cavity.
Water-Bath Calibration Device with Data Storage Using Six Thermocouple Sensor Yanti Kusumawardani; Endang Dian Setioningsih; Dyah Titisari
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 2 No 2 (2020): July
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v2i2.2

Abstract

Uneven temperature distribution in the water-bath chamber can cause the temperature conditions in the chamber are not the same. Temperature, humidity, atmospheric pressure, and dust particles are the main factors that adversely affect the accuracy of the water bath's temperature. Therefore, the purpose of this study is to design a calibration device for water-bath with six-channel temperature sensors. In this study, the system able to detect temperatures at each point. The K-type thermocouple sensor is used to detect the temperature at each chamber point with the help of the MAX6675 module as a signal conditioning amplifier. The sensor readings will be displayed on a personal computer using a USB cable, and the sensor readings can be stored on a personal computer in the TXT format so that the data can be reprocessed using Microsoft Excel for further calibration purposes. This study aims to facilitate the calibration process and the processing of calibration data. Based on the obtained measurements, a temperature error for 40 ° C channel one 1.4 %, channel two 1.8%, channel three 0.4%, channel four 0.2%, channel five 0.2% and channel 6 0.2%. Furthermore, the accuracy for temperature setting of 50 ° C for channel one 2.25%, channel two 2.26%, channel three 2.00%, channel four 2.44%, channel five 2% and channel six 1.6%. Moreover, the accuracy for setting temperature 60 ° C for channel one is 0.3%, channel two 0.6%, channel three 0.5%, channel four 1.5%, channel five 2% and channel six 1.8%. Based on the test results, this design has the lowest error of 0.2% and the highest error of 2.44%. The results of this research can be implemented as a water bath calibrator device to maintain the temperature stability of the instrument.
Oximeter and BPM on Smartwatch Device Using Mit-App Android with Abnormality Alarm Bedjo Utomo; Syaifudin Syaifudin; Endang Dian Setioningsih; Torib Hamzah; Parameswaran Parameswaran
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 2 (2021): July
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v3i2.4

Abstract

Monitoring is an activity that is carried out continuously. Healthy condition is a parameter that is needed in life, one of the important parameters is the measurement of oxygen saturation in the blood and heart rate. The purpose of this research is to develop a Smartwatch SpO2 device and BPM sensor that is connected to WIFI using the Android Platform instead of using an LCD for parameter reading. This module design method uses the MAX30100 sensor to display the SpO2 and BPM values ​​displayed on the OLED. Data processing is carried out using ATMEGA 328P programming and then displayed in the Android-based Mit-app application. The results show the average error for the SPO2 value is 0.868 % and the standard deviation is 0.170 %, while the BPM value has an average error of 0.56 % and a standard deviation of 0.30%. From the results of the comparison data analysis, the largest error was 1.03% and the smallest was 0.62% for Spo2 ml/hour with an accuracy of 0.05 (0.57%) with a precision value of 0.08 at the selection speed of 50 ml/hour. From the results above, it can be concluded that the data can be displayed on OLED using the Mit-app Android application with an error rate accuracy of 0.57%. From the results of this research design, it is hoped that it can facilitate the diagnosis of the condition of patients and health nurses
Comparative Analysis of PID and Fuzzy Temperature Control System on Infant Warmer Abdul Majid; Endang Dian Setioningsih; Abd Kholiq; Singgih Yudha Setiawan; Anilkumar Suthar
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 4 (2022): October
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v4i4.257

Abstract

Infant Warmer is a life support equipment that is used to provide heat relief for normal and premature babies who are unable to maintain their own body temperature when in a new environment. The purpose of this research is to design an infant warmer using the DS18B20 sensor to analyze the efficiency and effectiveness between PID and fuzzy temperature control. This study used temperature settings of 34 °C, 35 °C, and 36 °C. The tool used for reference from standard measurements uses a standard infant warmer. When using the PID control used in the microcontroller detects the set temperature difference value with the actual temperature, the difference in value will be input to the PID control. The error value becomes PWM input on the PID control, the PID control will process the error value and determine the output value for the heater, the temperature sensor will read the actual temperature value which will be compared again with the temperature setting, the PID control will continue to process the error value and determine the PWM output value. until the actual temperature is equal to the setting temperature or the error value is zero