4 Channel Sterilizer Calibrator Syafiq Naufal Syayakti; Endang Dian Setioningsih; Sumber Sumber
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 1 No 2 (2019): November
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v1i2.4

Abstract

Thermocouple (Thermocouple) is a type of temperature sensor used to detect or measure temperature through two types of metal conductors, whose working principle is that each end of a metal conductor is combined to create a "Thermoelectric" effect. One type of metal conductor contained in a thermocouple will serve as a reference with a constant temperature (fixed), while a metal conductor functions as a metal conductor that detects hot temperatures. Sterilisator is a device used to sterilize medical instruments to avoid the bacteria that attach to the remainder of the use of medical instruments. The temperature of the sterilizer varies but generally for dry sterilizers ranges from 175 ° Celsius. From the above problems, the author wants to develop a "4 Channel Sterilizer Calibrator", Using the Arduino Nano Atmega328 as a minimum system, K type thermocouple and MAX6675 module as a sensor. Measurements were made by comparing modules with standard measuring instruments, obtained the smallest error 0.2% at T3 and T4 when measuring 100 ° C, and the largest 4.4% at T2 when measuring 150 ° C.
Electronic Stethoscope Design with IoT (Internet of Things)-based Disease Symptom Detection Torib Hamzah; Endang Dian Setioningsih; Sumber Sumber; Nazila Ragimova
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 4 No 4 (2022): November
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v4i4.247

Abstract

Auscultation is a technique or method most often used by medical personnel in the initial examination of patients. One way is to use a stethoscope. However, this method has its drawbacks because the diagnosis is carried out subjectively and cannot be relied on with the accuracy to diagnose the symptoms of heart defects. Thus, the purpose of this study is to create an IoT system for electronic stethoscopes with BPM value output and make analog filters to eliminate noise interference which was a major obstacle in previous studies. The contribution to this study is to make it easier for medical users to monitor vital conditions, namely BPM remotely and produce BPM values in real-time. The method used in this study was to use a mic condensor placed on the patient's chest to detect pressure changes that occurred. This change in pressure causes a change in the voltage output value on the condensor mic. Output dari mic condenser masuk dan diproses di rangkaian PSA. Output sinyal dari PSA masuk ke mikrokontroler yang telah diprogram. Hasil yang dipeoleh dari pengukuran mengasilkan nilai error pengukuran nilai BPM dari 5 responden dan diperoleh nilai error yang dihasilkan dari responden 1 diperoleh error sebesar 0.33 BPM, responden 2 diperoleh nilai error sebesar 0,67 BPM, responden 3 memiliki nilai error sebesar 0,5 BPM, responden 4 nilai error sebesar 0,67 dan responden 5 mempunyai nilai error sebesar 0,67 BPM. The results of the statistical test were also obtained P-Value>0.05 which explained that the resulting value did not have a significant difference and could be used for medical purposes. This research can help make it easier for doctors to analyze and diagnose symptoms of heart defects because this system is equipped with the detection of disease symptoms.
Analysis of Dialysate pH and Temperature Stability on Hemodialysis Machines Using Internet of Thing Technology Noviyanto Putera P; Lusiana Lusiana; Endang Dian Setioningsih; Sari Luthfiyah; Abhilash Pati
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 5 No 1 (2023): February
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v5i1.267

Abstract

Therapy for kidney replacement with hemodialysis is a treatment that is carried out in patients with Chronic Kidney Failure to survive. The purpose of this study was to determine the stability of the dialysate fluid in the hemodialysis machine by measuring the temperature using the DS18B20 sensor and measuring the dialysate pH using the 4502C sensor on pre and post-hemodialysis. The research method and the manufacture of this module use a pre-experimental research design with the type of research "one group posttest design" the independent variables are the pH value and Dialysate Temperature, the dependent variable is the pH and Temperature Sensor, the control variable is the Traceable Tool. This research made a module using an Esp32 microcontroller system with an LCD that can be monitored with Android via the Internet of Things (IoT) system. 03 and the comparison of the results of the dialysate temperature values ​​at the time of pre and post-obtained the maximum measurement error of 0.2%. From the measurement and analysis data, it can be concluded that there is no effect of pH and temperature values ​​during pre and post hemodialysis.
Analyzing the Relationship between Dialysate Flow Rate Stability and Hemodialysis Machine Efficiency Baharudin Adi Baharsyah; Endang Dian Setioningsih; Sari Luthfiyah; Wahyu Caesarendra
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 5 No 2 (2023): May
Publisher : Department of electromedical engineering, Health Polytechnic of Surabaya, Ministry of Health Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v5i2.276

Abstract

Chronic kidney disease (CKD) is a condition characterized by impaired kidney function, leading to disruptions in metabolism, fluid balance, and electrolyte regulation. Hemodialysis serves as a supportive therapy for individuals with CKD, prolonging life but unable to fully restore kidney function. Factors influencing urea and creatinine levels in hemodialysis patients include blood flow velocity, dialysis duration, and dialyzer selection. This research aims to establish a standard for calculating the dialysate flow rate, thereby enhancing dialysis efficiency. The study employs a pre-experimental "one group post-test" design, lacking baseline measurements and randomization, although a control group was utilized. The design's weakness lies in the absence of an initial condition assessment, making conclusive results challenging. Measurement comparisons between the module and the instrument yielded a 5.30% difference, while the difference between the hemodialysis machine and standard equipment was 4.02%. Furthermore, six module measurements against three comparison tools showed a 0.17% difference for the hemodialysis machine with standard equipment, and a 0.18% difference for the module with standard equipment, with a 0.23% discrepancy between the two. Further analysis is necessary to understand the clinical significance and implications of these measurement variations on overall dialysis efficacy