Claim Missing Document
Check
Articles

Found 7 Documents
Search

Penerapan Teknologi Mesin AC Mobil Bagi Siswa Jurusan Teknik Otomotif Di SMK Negeri 1 Losarang Wardika; Sunanto; Dedi Suwandi; Munengsih Sari Bunga
Journal of Applied Community Engagement Vol 1 No 1 (2021): Journal of Applied Community Engagement (JACE)
Publisher : ISAS (Indonesian Society of Applied Science)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (638.668 KB) | DOI: 10.52158/jace.v1i1.164

Abstract

SMKN 1 Losarang is a vocational education institution where the level of mastery of skills is the main point in graduate output. Completeness of learning facilities and practical facilities in achieving competence in the automotive sector is certainly a necessity that must be fulfilled. By looking at a large number of students in the Automotive engineering department while the practicum facilities are still very minimal, the limited practicum facilities in supporting competency in the automotive field become an obstacle considering the ratio of the number of students to car AC trainer machines is 1:36 so that a solution is needed, namely increasing the number of facilities in the form of car AC engine trainers to improve student competence at SMK N 1 Losarang. With the application of car AC engine technology, the competence of students majoring in Automotive has increased by 20.5%. This is based on the comparison of the free test value to the post-test score that has been done
ANALISIS PENGARUH VARIASI PUTARAN EXTRA FAN EVAPORATOR TERHADAP KINERJA COLD STORAGE MENGGUNAKAN MESIN OUTDOOR AC SPLIT UNTUK PENYIMPANAN PUREE MANGGA Setiawan, Aa; Wardika; Imam, Muhammad
JURNAL REKAYASA ENERGI Vol. 2 No. 2 (2023): Jurnal Rekayasa Energi
Publisher : Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jre.v2i2.41

Abstract

Penambahan ekstra fan pada evaporator cold storage menggunakan mesin outdoor AC split 2 PK dimaksudkan untuk meningkatkan laju aliran udara dan penyerapan panas dari kabin agar tidak terjadi defrost pada sirip evaporator serta meningkatkan kapasitas pendinginan. Untuk menghindari energi yang berlebihan, perlu dilakukan pengujian laju aliran udara yang ideal agar diketahui nilai efisiensi maksimum. Penelitian ini dilakukan dengan tujuan mengamati pengaruh variasi putaran extra fan evaporator low, medium, dan high terhadap kinerja cold storage. Pengujian dilakukan dengan menjalankan sistem menggunakan beban 500 kg air sampai air tersebut mencapai temperatur 60C. Dari hasil pengujian didapat efisiensi untuk kecepatan extra fan evaporator low sebesar 76%, extra fan evaporator medium sebesar 78%, dan extra fan evaporator high sebesar 84%.
ANALISIS BATERAI EMERGENCY PADA INKUBATOR BAYI DENGAN VARIASI DAYA LAMPU PIJAR 25 WATT DAN 50 WATT Kurniawan, Yudhy; Wardika; Winani; Utami, Sasi
JURNAL REKAYASA ENERGI Vol. 2 No. 2 (2023): Jurnal Rekayasa Energi
Publisher : Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jre.v2i2.42

Abstract

Salah satu penyebab kematian bayi dikarenakan bayi berat lahir rendah (BBLR), kondisi ini banyak dialami oleh bayi prematur, dimana kondisi prematur menyebabkan hipotermia. Untuk itu bayi prematur harus segera mendapatkan perawatan inkubator. Tujuan penelitian ini adalah bagaimana pemanfaatan baterai darurat pada inkubator bayi, sehingga kondisi suhu bayi dalam inkubator tetap terjaga terutama disaat terjadi pemadaman listrik dari PLN. Metode yang dilakukan pada penelitian ini dengan pengujian pada berbagai variasi beban lampu pemanas pada inkubator terhadap baterai darurat yang digunakan. Untuk kapasitas baterai yang digunakan sebesar 9 Ah, 12 volt. Hasil pengujian yang didapat menunjukkan untuk variasi beban lampu pemanas 25 W, lampu dapat beroperasi selama 205 menit (3 jam 42 menit). Sedangkan pada variasi beban lampu 50 W, lampu beroperasi selama 140 menit (2 jam 33 menit).
PENGARUH VARIETAS CABAI TERHADAP KINERJA PROTOTIPE COLD ROOM Wardika; Sugara, Ferry; Ismail; Maknunah, Jauharotul
JURNAL REKAYASA ENERGI Vol. 3 No. 1 (2024): Jurnal Rekayasa Energi
Publisher : Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jre.v3i1.56

Abstract

Tujuan dari penelitian ini adalah untuk menyelidiki dampak dari berbagai varietas cabai terhadap kinerja cold room. Cold room yang digunakan memiliki volume sebesar 0,175 m3 dengan kapasitas produk sebanyak 2 kg. Selama penelitian, temperatur kabin dipertahankan antara 6 °C hingga 12 °C, dengan kelembapan berkisar antara 87% hingga 90%. Untuk mencapai temperatur dan kelembapan yang diinginkan, kabin cold room dilengkapi dengan pompa air untuk sirkulasi. Produk yang digunakan dalam penelitian ini mencakup berbagai varietas cabai, seperti cabai rawit, cabai merah, dan cabai hijau. Hasil penelitian pengawetan berbagai varietas cabai menunjukkan bahwa cold room memiliki kinerja yang berbeda untuk setiap varietas. Nilai Koefisien Performa (COP) untuk cabai rawit adalah 5,4 dengan efisiensi sebesar 80,8%. Sementara itu, untuk cabai merah, nilai COP adalah 5,5 dengan efisiensi sebesar 80,7%, dan untuk cabai hijau, nilai COP adalah 5,6 dengan efisiensi sebesar 81,3%.
Analysis of The Effect Evaporator Fan Rotation Variations on Air Blast Freezer Performance for Freezing Mango Puree Wardika; Yudhy Kurniawan; Aa Setiawan; Muchammad Zuhda Alifun Naja
Logic : Jurnal Rancang Bangun dan Teknologi Vol. 24 No. 3 (2024): November
Publisher : Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31940/logic.v24i3.150-159

Abstract

Mangoes are the main commodity in Indramayu Regency, but they are easily damaged after harvesting due to improper mango processing. One solution to overcome this problem is to process mangoes into puree. This process requires freezing technology such as an air blast freezer machine. The evaporator fan functions to prevent blocking of the evaporator fins and distribute cold air so that the room temperature reaches -18˚C. This research aims to determine the effect of variations in evaporator fan rotation on the performance of the air blast freezer system. Data are taken every 10 minutes until the mango puree reaches the set point temperature. Three experiments were conducted with evaporator fan speeds set to low (1800 RPM), medium (2200 RPM), and high (2600 RPM). Based on the tests that have been carried out, the system performance at low fan rotation produces an actual Coefficient of Performance (COP) of 1.9 with an efficiency of 41% and electricity costs of IDR 462,900. Medium fan rotation produces an actual COP of 2.0 with an efficiency of 43% and electricity costs of IDR 469,380. High fan rotation produces an actual COP of 2.1 with an efficiency of 45%. This research shows how variations in fan speed affect the COP, system efficiency, and operational costs, therefore the results of this research contribute to the development of energy efficient and economical cooling technology, especially for tropical-based food preservation applications such as fruit puree mango.
ANALISIS STUDI EKSPERIMENTAL DISTRIBUSI KALOR PADA INKUBATOR BAYI PORTABEL Yudhy Kurniawan; Wardika; Karsid; Agustina, Dea
JURNAL REKAYASA ENERGI Vol. 3 No. 2 (2024): Jurnal Rekayasa Energi
Publisher : Politeknik Negeri Indramayu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31884/jre.v3i2.69

Abstract

Dalam penelitian ini menggunakan lampu pijar sebagai media Pemanas Inkubator Bayi Portabel. Alasan dari penelitian ini adalah karena penempatan lampu pijar hanya di satu sisi saja oleh karena itu, tujuannya untuk mengetahui berapa lama persebaran suhu secara merata dan untuk mengetahui jumlah kalor pada setiap titik T1, T2, T3, T4, dan T5. Dalam hal ini untuk masing-masing titik pada ruang Inkubator Bayi dinotasikan T1, T2, T3, T4, dan T5. Metode penelitian ini mencakup studi  literatur, persiapan alat dan bahan, pengujian sistem, dan pengolahan data. Pengujian dilakukan selama dua jam, suhu dipantau dan dicatat tiap lima menit sekali. Hasilnya sebaran suhu dalam inkubator sudah mulai merata mencapai suhu optimal selama 55 menit, dan nilai kalor radiasi yang didapat dari masing titik adalah T1 = 11,27W, T2=8,97W, T3=8,32W, T4= 11,59, T5=13,21W. Suhu lampu dan suhu lingkungan sekitar dapat berpengaruh terhadap persebaran kalor dalam Inkubator Bayi Portabel, semakin besar nilai selisih suhu sumber lampu dengan suhu ruang maka nilai kalor yang dihasilkan semakin besar juga.
Analysis of The Effect Evaporator Fan Rotation Variations on Air Blast Freezer Performance for Freezing Mango Puree Wardika; Yudhy Kurniawan; Aa Setiawan; Muchammad Zuhda Alifun Naja
Logic : Jurnal Rancang Bangun dan Teknologi Vol. 24 No. 3 (2024): November
Publisher : Unit Publikasi Ilmiah, P3M, Politeknik Negeri Bali

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31940/logic.v24i3.150-159

Abstract

Mangoes are the main commodity in Indramayu Regency, but they are easily damaged after harvesting due to improper mango processing. One solution to overcome this problem is to process mangoes into puree. This process requires freezing technology such as an air blast freezer machine. The evaporator fan functions to prevent blocking of the evaporator fins and distribute cold air so that the room temperature reaches -18˚C. This research aims to determine the effect of variations in evaporator fan rotation on the performance of the air blast freezer system. Data are taken every 10 minutes until the mango puree reaches the set point temperature. Three experiments were conducted with evaporator fan speeds set to low (1800 RPM), medium (2200 RPM), and high (2600 RPM). Based on the tests that have been carried out, the system performance at low fan rotation produces an actual Coefficient of Performance (COP) of 1.9 with an efficiency of 41% and electricity costs of IDR 462,900. Medium fan rotation produces an actual COP of 2.0 with an efficiency of 43% and electricity costs of IDR 469,380. High fan rotation produces an actual COP of 2.1 with an efficiency of 45%. This research shows how variations in fan speed affect the COP, system efficiency, and operational costs, therefore the results of this research contribute to the development of energy efficient and economical cooling technology, especially for tropical-based food preservation applications such as fruit puree mango.